OPQR requires a firm-fixed-price contract for the procurement and installation of one Quasi-Elastic Light Scattering (QELS) Dynamic Light Scattering Detector. The system must integrate seamlessly with an existing Field-Flow Fractionation (FFF) system and MALS detectors to provide real-time hydrodynamic radius measurements for pharmaceutical products and biologics, specifically covering a range from 10 nm to 1000 nm. The contractor is responsible for providing the hardware, software licensing, and all necessary connectors, as well as ensuring the system generates audit-trail-compliant data suitable for regulatory submissions. The delivery of the unit, including installation, instrument qualification, and staff training, must be completed within 120 days of the contract award. Full acceptance is contingent upon the successful completion of Installation and Operational Qualification (IQ/OQ). The period of performance extends for 12 months from the installation date, during which the contractor must provide technical support, software updates, and on-site performance qualification. The equipment will be installed at the FDA Center for Drug Evaluation and Research in Saint Louis, Missouri.
General Info
Agency
NAICS
Place of Performance
Saint Louis, MO, 63110, USASet-Aside
Documents
(1)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
Response Deadline
Organization & Contact Information
Full Description
OPQR has a requirement to obtain an advanced dynamic light scattering detector to enhance characterization capabilities for emerging pharmaceutical products and complex biologics. For a quoter's detector to be deemed acceptable, the following salient characteristics shall be met:
- QELS Dynamic Light Scattering Detector: Real-time hydrodynamic radius measurement capability that operates inline with Field-Flow Fractionation separation to provide simultaneous size characterization as samples elute from the FFF system.
- Compatibility with Existing FFF System: Must be fully compatible with and integrate seamlessly into the existing FFF system, including hardware connections, software integration with chromatography software, and synchronized data acquisition with existing MALS detectors.
- High-Sensitivity Detection: Capable of measuring hydrodynamic radii across a wide dynamic range from approximately 10 nm to 1000 nm to accommodate diverse sample types including proteins, protein aggregates, liposomes, and lipid nanoparticles.
- Orthogonal Size Validation: Provides diffusion-based size measurements that complement separation-based FFF analysis, enabling validation of particle size distributions and detection of sub-populations or aggregates that may not be fully resolved by separation alone.
- Data Correlation and Analysis: Integrated software functionality that enables direct correlation between molecular weight data from MALS detection and hydrodynamic size from DLS detection to provide comprehensive analysis of absolute molar mass, root-mean-square radius, and hydrodynamic radius.
- Data Output: Generates validated, audit-trail-compliant data files suitable for regulatory submissions and scientific publications, with full integration into existing software platform for unified data processing and reporting.
- Maintenance and Support: Technical support, software updates, preventive maintenance, and alignment with FDA's quality assurance requirements for analytical instrumentation.
-
3.4 Deliverables
Ref
Description
Quantities Required
Due Date
3
Quasi-Elastic Light Scattering Unit for FFF
1
120 days after award
3
Installation, instrument qualification and training
1
120 days after contract award.
Detector hardware with all necessary cables, connectors, and mounting hardware for integration with existing FFF system. Software licensing and installation files compatible with current chromatography software version. User manuals, technical specifications, and standard operating procedure templates provided in digital format via download or physical media (CD/DVD). CD, DVD and hard copies of deliverables shall not be required to be returned to the Contractor. Deliverables are delivered to the following address:
U.S Food and Drug Administration
Center for Drug Evaluation and Research / Office of Pharmaceutical Quality / Office of Pharmaceutical Quality Research
Attn: TBD
645 S Newstead Avenue
St. Louis, M0 63110
3Schedule: Delivery shall be no later than 120 days after contract award.
Vendor is responsible for coordination with FDA staff for installation and integration with existing FFF system. FDA staff will provide access to laboratory space and existing instrumentation for installation activities.
3.6 Maintenance and Technical Support: At minimum the contractor must:
- Provide support via email, phone, and/or web conference for troubleshooting and technical assistance.
- Provide on-site installation, integration testing, and performance qualification of the detector with existing FFF-MALS system.
- Provide on-site training for FDA staff on detector operation, data analysis, method development, and routine maintenance procedures.
- Inspection and Acceptance Criteria
-
Partial acceptance is made upon delivery of all the parts. Full acceptance is made after completion of Installation and Operational Qualification (IQ/OQ) by the contractor that the system meets all the specifications and requirements.
-
- Terms of Use
-
Fixed Term License: FDA shall the ability to purchase a new subscription after the original subscription expires to continue the use of the software and to gain access to technical support and product upgrades.
-
- Period of Performance
-
The period of performance is 12 months from the installation date of the system. The delivery of the entire system with accessories as outlined in the SOW should be completed within 120 days of award. Instrument installation and qualification should be completed within 120 days of award. Instrument familiarization and training should be completed on the day of installation.
-
- Options
-
None
-
- Order Type
-
The order type is firm-fixed-price.
Similar Contracts
Same NAICS industry code
More opportunities from Department Of Health And Human Services → FDA Office Of Acq Grant Svcs
Same awarding agency
Ready to Pursue This Opportunity?
Get AI-powered intelligence on this solicitation and the ones like it
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS