Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on November 20, 2015. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Radio Frequency Antenna Tower Repair

Closed
W91ZLK-15-T-0288Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811213
SLED
Piper Tech Video Management System
Solicitation # 231722
The City of Los Angeles Mayor's Office of Public Safety is soliciting proposals for the design, installation, and commissioning of an IP-based video surveillance system at the C. Erwin Piper Technical Center. Funded by the FY2024 UASI Grant with a fixed-price budget not to exceed 400,000 dollars, the project requires the installation of at least 26 high-resolution IP cameras, including P3738-PLE and Q6088-E PTZ models. The technical scope includes deploying a Genetec Security Center VMS platform, high-performance Dell recording servers, and workstations, supported by Category 6 plenum-rated cabling and a hybrid copper/fiber network backbone. Key performance requirements include AI-based perimeter detection and a minimum of one year of continuous 24/7 video retention at 30fps and full resolution. The performance period begins upon contract execution and ends on January 31, 2027. Award decisions will be based on the quality and value provided for the fixed price, with an evaluation process that may include virtual presentations for high-scoring semi-finalists. Contractors must adhere to strict standards, including FEMA Environmental and Historic Preservation guidelines, ANSI/TIA-606-D cabling standards, and LAPD/ITA cyber hardening protocols. Final acceptance is contingent upon successful System Acceptance Testing and User Acceptance Testing, including 100 percent cable certification reports. Proposals must be submitted in PDF format via email to the designated point of contact by October 30, 2026.
Mayor Office

POSTED

about 1 month ago

DEADLINE

in 10 days

General Info

Contract Value

$98,812.36

NAICS

811213 - Communication Equipment Repair and Maintenance

Place of Performance

Aberdeen Proving Ground, various locations, ABERDEEN PROVING GROUND, MD, 21005, USA

Set-Aside

NONE

Award Issued Date

Documents

9

A01_W91ZLK-15-T-0288__Inspection_report_combined.pdf

PDF

A02_W91ZLK-15-T-0288_Combined_Synopsis_Solicitation_8-25-15.pdf

PDF

A02_W91ZLK-15-T-0288_Combined_Synopsis_Solicitation_amend_2.pdf

PDF

A02_W91ZLK-15-T-0288_Combined_Synopsis_Solicitation_amend_3.pdf

PDF

A02_W91ZLK-15-T-0288_Combined_Synopsis_Solicitation_Amend_4_Antenna_Removal.pdf

PDF

A02_W91ZLK-15-T-0288_Combined_Synopsis_Solicitation_amend_4.pdf

PDF

A02_W91ZLK-15-T-0288_Combined_Synopsis_Solicitation_amend_4_Q%26A.pdf

PDF

A02_W91ZLK-15-T-0288_Combined_Synopsis_Solicitation_Amend_4_Site_Visit_Photos.pdf

PDF

A02_W91ZLK-15-T-0288_Combined_Synopsis_Solicitation_amend_8-31.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

4 updates
PhaseClosed
Posted

Combined Synopsis

Notice updated

Response deadline changed from Sep 29, 2015 to Nov 6, 2015. The notice description changed. The point of contact changed.

Notice updated

The notice description changed.

Notice updated

Response deadline changed from Nov 6, 2015 to Nov 20, 2015. The notice description changed.

Notice updated

Notice details unchanged. Attachments may have changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W6QK Acc-Apg Director
Contacts2 people available
OfficeABER PROV GRD, MD, 21005, USA
Office AddressABER PROV GRD, MD, 21005, USA
Contacts
Amy DuBreePurchasing Agent
Chanel D. De SilvaContracting Officer

Full Description

Show more
Radio Frequency Antennae Tower Repair for 6 Towers. See Attachments. Revised Dates for questions deadline and proposal deadlines to accomodate site visit. Revised Performance Work Statement, see attachment. Q&A Question: Will/Can a site visit be scheduled? Answer: Yes, Site visit details are in progress. Additional information will be forthcoming. SITE VISIT 6-7 OCT 2015, 0800-1600 both days. This will be a two day site visit to view all six towers. Question: Is there a list of antennaes and equipment that is to be removed from each tower? Answer Yes Question: Where ground buss bars are installed do you want all coax lines grounded to the bus bar? Answer: Yes If so, is there a list of coax sizes and quantity per tower? Answer: No Question: Where is says properly secure feed lines, do you want the stainless clamps most commonly used in the communications industry or wire ties, tape, ty-wraps, etc? Answer: Stainless clamps Question: 2.3 BLDG 436; #2.3.1 Repair or replace all damaged/missing tower structural member(s) to include legs and braces. Is there a list of members that need replacement? Answer: No Question: Are tower drawings available for this tower? Answer: No Question: 2.5 H-Field; 2.5.1 Furnish and install ASTM 325 structural bolts. In the pictures the bolts appear to be foundation bolts at the base of the tower. Are you wanting the foundation bolt removed and/or the nut and lock washer? Answer: Replace bolt, nut and washer Question: Is there a drawing or plan on how to replace a foundation bolt? Answer: No Question: 2.4 Munson Test Course. In the pictures there is a rusted indoor cable tray used as a cable bridge and as a cable ladder up the tower. Each picture caption states replaces Cable Bridge (not to exceed 10'x10'x24'). There is no item in the SOW for this site about these items, only in the pictures. Do you want to replace the horizontal cable bridge or the cable ladder on the tower or both or no action? Answer: No requirement for the cable bridge to be replaced on the Munson Test Course Tower. Question: Section 2.3.3 How will the government evaluate the cost for this task since the vendor will not be able to identify the cost until after they have troublshoot the lights and determine if they can be repaired or will need to be replaced? Answer: Please provide seperate repair and replacement costs. AMENDMENT#2 includes Site Visit information and adjusted dates for questions and bid submission AMENDMENT #3 corrects site visit attendance response date to 29 September 2015. AMENDMENT #4 This amendment extends bid date to 20 Nov 2015, provides Q&A from site visit, provides pictures from site visit, provides details for antenna removal on towers, and revision to SOW. Please review attachments for specifics. One question from Q&A has not been answered. As soon as information is available it will be provided.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS