Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on June 10, 2009. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Design/Build, Installation of Water Meters & Repair of Water Mains

Awarded
FA3047-09-R-0015Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237110
New
Federal
Z2NZ-- 658-23-108 Correct Stormwater Drainage
Solicitation # 36C24626B0031
Solicitation 36C24626B0031 is a firm-fixed-price sealed bid invitation for Project 658-23-108, which entails correcting stormwater drainage at the Salem VA Medical Center in Salem, Virginia. The project is a 100% set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 237110. The estimated magnitude of construction is between $10,000,000 and $20,000,000, with a performance period of 450 calendar days from the issuance of the Notice to Proceed. The scope of work includes general construction and utility work, specifically requiring the installation and 24/7 operation of a dewatering system and the use of flowable fill for backfilling in designated areas. The award will be made to an eligible SDVOSB that meets specific qualification criteria, including the completion of three projects of similar complexity and value within the last three years and a clean record regarding EPA and OSHA asbestos regulations. The prime contractor is required to perform at least 15% of the construction work. Bidders must be registered in the System for Award Management (SAM) and provide a bid guarantee of at least 20% of the bid price, capped at $3,000,000. Following several amendments, the final bid submission deadline is November 10, 2026, at 5:00 PM EST. Required submission documents include a signed SF 1442 offer page, an SF 24 bid bond, and a signed VAAR 852.219-75 Certificate of Compliance.
246-NETWORK Contracting Office 6 (36C246)

POSTED

about 4 hours ago

DEADLINE

in 21 days
NAICS: 237110
New
Morgans Branch Force Main and Pump Station Improvements
Solicitation # SRP-W-134-0290
The Morgans Branch Force Main and Pump Station Improvements project, solicitation number SRP-W-134-0290, is a construction contract for the City of Belmont in North Carolina with a project estimate of 16,690,000 dollars. The scope of work involves the construction of 16,435 linear feet of new 20-inch ductile iron force main and comprehensive upgrades to the Morgans Branch Pumping Station. Key infrastructure improvements include the installation of a new wet well, valve vault, and associated appurtenances, as well as the demolition of existing pumps and piping. The contractor is responsible for delivering a fully operational station featuring mechanical and electrical systems, including pumps, a generator, and odor control equipment, along with new gravity sewers and manholes. The contract is a small business set-aside and will be awarded to the responsible bidder submitting the lowest responsive bid. Bids must be submitted using the EJCDC C-410 form and include a bid bond, evidence of signing authority, and MWBE compliance documentation. Performance and payment bonds are required upon award. Project administration follows EJCDC standard general and supplementary conditions, with payments processed monthly via applications for payment reviewed by the Engineer. Final acceptance is contingent upon a substantial completion inspection, the resolution of a punch list, and a final inspection conducted by the Owner, Contractor, and Engineer.
Don Moorhead Construction, Inc.

POSTED

about 10 hours ago

DEADLINE

in 20 days

AI Contract Overview

Show more

The contract involves a design-build project focused on the replacement of approximately 25,000 linear feet of water lines and the installation of water meters at around 60 facilities within a military base in San Antonio, Texas. The contractor, HCR Construction Inc., is tasked with providing a complete design package for water main replacements and meter installations, including plans, specifications, design analysis, and cost estimates. Design submissions will occur in two stages, at 65% and 95% completion, with government approval required before moving forward, and construction will begin only after acceptance of the final design. The scope of work includes abandoning existing water mains, installing new 6-inch and 8-inch AWWA C900 PVC pipes, and replacing about 40 fire hydrants and 70 main line isolation valves. Additional valves and hydrants must also be installed as necessary to meet design standards. The contractor will relocate approximately 50 service lines and restore all excavated areas to their original condition. All work must comply with relevant drawings, specifications, and applicable codes, ensuring a fully functioning water system. The contract is administered by the Department of Defense and emphasizes accountability under the American Recovery and Reinvestment Act of 2009.

General Info

Design-build contract for water line replacement, meter installation, fire hydrant upgrades, and valve installation at military base.

Contract Value

$3,825,050.8

NAICS

237110 - Water and Sewer Line and Related Structures Construction

Place of Performance

37 Contracting Sq, SAN ANTONIO, TX, 78236, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Presolicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA3016 502 Cons Cl
Contacts2 people available
OfficeJBSA LACKLAND, TX, 78236-5286, USA
Office AddressJBSA LACKLAND, TX, 78236-5286, USA
Contacts
Ryan D. BuenoCONTRACT SPECIALIST
Jackie L. MurrayTeam Lead/Contracting Officer

Full Description

Show more
In compliance with the transparency and accountability requirements associated with the supplemental appropriations provided by the American Recovery and Re-investment Act of 2009, Pub.L. 111-5, the Government posts this presolicitation notice of intent to issue an 8(a) Sole Source Request for Proposal to HCR Construction Inc., 1605 Chattahoochee Run Dr. Suwanee, GA 30024. The Project description is as follows: PROJECT SCOPE Contractor shall provide a complete design (Title I Services A & B) for the replacement of approximately 25000 linear feet of water lines in the 7000 area and for the installation of water meters at approximately 60 facilities base wide. All work shall be in conformance with the drawings and specifications and with applicable codes, standards and regulations and shall include the furnishing of all materials, labor, plant, tools, equipment, and services necessary and incidental thereto. The work required to be performed by the contractor shall consist of but is not limited to the following principal items: --DESIGN Contractor shall provide a complete design for the replacement of water mains and the installation of water meters. The design shall consisting of plans, specifications, design analysis and cost estimate. A design package shall be submitted at the 65% and 95% stages of design. The 65% design submittal will be reviewed and accepted by the government prior to continuation to 95%. Construction will commence upon acceptance of the 95% design submittal. --WATER MAIN REPLACEMENT Existing water mains shall be abandoned in place. Contractor shall install approximately 12,500 linear feet of 6 AWWA C900 PVC pipe and approximately 12,500 linear feet of 8 AWWA C900 PVC pipe in the area bordered approximately by Treumper , Carswell and Tinker streets and as shown on project location map. Contractor shall demo and replace approximately 40 existing fire hydrants and associated fire hydrant valves. Contractor shall replace approximately 70 existing main line isolation valves. Contractor shall demo existing valve boxes. Contractor shall install additional isolation valves and fire hydrants as necessary to meet applicable design criteria. All valves and fire hydrants shall be right handed (right = closed). Contractor shall relocate approximately 50 service lines from existing mains to new mains. Contractor shall restore excavated areas to existing conditions. Contractor shall provide all materials, labor, plant, tools equipment and services necessary to provide a complete and fully functioning system in compliance with design drawings, specifications and submittal register and in conformance with all applicable codes, standards and regulations.

More opportunities from Department Of Defense → FA3016 502 Cons Cl

Same awarding agency

NAICS: 238210
New
Federal
DCF3 PROJECTION SYSTEM
Solicitation # A070977
The Department of Defense, specifically the 502 Cons Cl under the Office of the Air Force, is issuing a sources-sought Request for Information (RFI) for the DCF3 Projection System, solicitation number A070977. The objective is to identify capable providers for the installation of standalone audio-visual (AV) classroom equipment in sixteen classrooms at the BMT DCF3 (Building 9270) located at JBSA-Lackland, Texas. The scope of work includes providing all personnel, equipment, and materials to install laser projectors, zoom lenses, lecterns, scaling switchers, and associated cabling. The system must operate as a standalone solution and is strictly prohibited from interfacing with the Air Force network. Key deliverables include the integration of Apple Government-Furnished Equipment, the provision of technical documentation, and the delivery of user training for staff. Technical requirements specify that projectors and extension columns must be Trade Agreement Act (TAA) compliant, and touch panels must be FCC Class A certified. The contractor is responsible for ensuring high video resolution and sound quality, with final acceptance based on a post-installation walkthrough and inspection at the project site. Security requirements are stringent, requiring criminal history checks and background investigations for all personnel accessing the base, as well as strict adherence to Force Protection Condition procedures and a total prohibition of weapons on site. This RFI is strictly voluntary and is not a formal solicitation for quotes; interested parties must submit their capabilities and open-market pricing via email to Tommie Low by October 27, 2026, at 10 a.m. CST.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

1 day ago

DEADLINE

in 7 days
View Details
NAICS: 238220
New
Federal
Brand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement
Solicitation # A070764SS
The 502d Contracting Squadron is conducting market research via a Sources Sought Synopsis to identify capable industry sources for the turnkey removal and replacement of 48 ceiling-suspended Dedicated Outside Air System Water-Source Heat Pumps at the JBSA Ft Sam Houston San Antonio Military Medical Center Dormitory Annex, specifically in buildings B3631 and B3635. The project is projected as a Firm-Fixed Priced Purchase Order under NAICS code 238220. The contractor must provide all personnel, equipment, and supervision to install units that meet strict technical specifications, including a 1.25-ton capacity, horizontal ceiling-plenum configuration, and the use of low-GWP refrigerants such as R-454B or R-32, as R-410A is strictly prohibited. A critical requirement is that replacement units must fit through existing access openings measuring approximately 3 feet 11.5 inches by 2 feet to avoid structural demolition. The scope of work includes the integration of the units into the central Building Automation System via BACnet IP/MSTP and the use of AHR/ISO 13256-1 certified water-to-refrigerant coaxial heat exchangers. Performance must be completed within 275 days of award. Interested respondents must provide company identification, SAM.gov certifications, and confirmation that technicians hold EPA Section 608 Universal Certifications. Small business prime contractors must also verify they can cover at least 51 percent of the contract cost with their own personnel. Responses are due by October 26, 2026, and must be submitted in PDF format with a maximum length of ten pages, excluding equipment cut sheets.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

6 days ago

DEADLINE

in 6 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS