Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity was posted on June 16, 2009. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

RECOVERY - Repair HVAC Various Research Lab Facilities

Awarded
FA930106D0010-FSPM031348Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237990
New
International
2383 Emerson Street - Modular Pump Track - Design-Build Services
Solicitation # RFP 1220-2026-4364
The City of Abbotsford has issued Request for Proposals RFP 1220-2026-4364 for design-build services to create a complete, safe, durable, and fully operational modular pump track facility at 2383 Emerson Street. The project follows a stipulated price contract based on the CCDC 14-2013 Design-Build Agreement. The selected Design-Builder will be responsible for all professional design and engineering services, including the preparation of sealed plans, as well as the provision of all labor, materials, modular pump track units, and site furnishings. Additionally, the contractor must obtain all necessary permits, licenses, and certificates of inspection required by federal, provincial, and local authorities. A mandatory site visit is scheduled for November 9, 2026, at 10:00 AM local time, and attendance is required for proposal submission. The deadline for responses is November 24, 2026, at 10:00 PM. Project acceptance is contingent upon the Consultant and Owner's satisfaction regarding the rectification of deficient work, completion of landscaping and clean-up, and the facility reaching full operational readiness. Payments will be processed via progress payment approvals issued by the City Representative. All work must adhere to the rules and customs of best trade practice and meet the requirements of all governing jurisdictions.
City of Abbotsford

POSTED

2 days ago

DEADLINE

in 23 days

AI Contract Overview

Show more

This firm-fixed price task order is awarded to Pojoaque Pueblo Construction Service for the repair and replacement of HVAC systems at various research lab facilities at Edwards Air Force Base. The project requires a turn-key solution involving the installation of a 50 ton chiller with heat strips at building 8765 and a chiller and CHW coil at building 4221, along with digital thermostats and necessary electrical distribution modifications. All work must comply with EAFB Design Standards and the latest International Electrical, Plumbing, and Mechanical Codes. The contractor is responsible for maintaining a clean and barricaded work area and must provide specific submittals, including factory start-up plans, layout sketches, and product data, for approval prior to commencement. Final project completion is contingent upon the delivery of system test results. The contract is governed by Davis-Bacon and Service Contract Act wage determinations and includes a one year warranty for both parts and labor.

General Info

Agency

N/A

Contract Value

$153,283.83

NAICS

237990 - Other Heavy and Civil Engineering Construction

Place of Performance

5 South Wolfe Avenue Edwards AFB, California 93524 United States, Edwards AFB, CA, 93524, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseAwarded
Posted

Presolicitation

Notice updated

Notice type changed from Presolicitation to Solicitation. The response deadline was removed. The notice title changed. The notice description changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts1 person available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts
Cheryle E ArmstrongContracting Officer

Full Description

Show more
RECOVERY - THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY. THIS OPPORTUNITY IS AVAILABLE ONLY TO CONTRACTORS UNDER BASE INFRASTRUCTURE CONTRACT (BIS) CONTRACT NUMBER FA9301-06-D-0010. Contractor: Pojoaque Pueblo Construction Service Cor. Rt 11 Box 8, Suite Const, Santa Fe, NM 87501. It is the Contracting Squadron's intent to award a firm-fixed price task order to the above contractor. Davis-Bacon wages presently in effect for California, CA030031 (Modification 26) dated 7/14/2006 and Service Contract Act 94-2045 (Rev. 28) dated 5/23/2006 will prevail. These acquisitions are subject to the North American Industry Classification Code 237990 and the annual size standard is $31.0 million. RECOVERY - Repair HVAC Various Research Lab Facilities - FSPM031348 THE PROJECT DESCRIPTION IS AS FOLLOWS: The work to be accomplished at Edwards AFB is removal and replacement of 1 chiller and pump wth heat strip at 8765, condenser with coil at 4221. The intent of this project is to provide a complete functioning stand alone HVAC system (Turn- Key) in place of the existing system. Work shall be accomplished in compliance with the EAFB Design Standards and applicable codes including the latest editions of the International Electrical, Plumbing and Mechanical Codes. The contractor shall accomplish the following: Install (1) 50 ton chiller with heat strips in the air handler 8765, Install (2) chiller and CHW coil in the existing air handler at 4221, Digital thermostat with night time set back, Modify the electrical distribution as required by NEC and manufacturers recommendation for all new equipment. During the construction effort, contractor shall barricade work area to prevent hazardous conditions. During the construction effort, contractor shall keep area clean at all times and remove all waste and dispose of waste in an appropriate manner. The contractor shall provide the follwing submittals to the COTR for review/approval prior to starting work: Fctory authorized Start-up, check out, Work plan and sketches indicating proposed layout of new equipment, Proposed penetrations including flashing and sealing techniques, Product data and/or cut sheets on insulation, and Test results of the new HVAC system shall be provided befor completion of the project. Warranty shall be (1) year parts and labor.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS