Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on August 29, 2018. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

REPAIR B317 WASH RACK

Closed
W912KC8204AW01Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238290
New
Centennial JCC Panic Hardware Services (Electrical Room Egress Doors)
Solicitation # Panic Hardware (Electrical Room Egress Doors)
Management & Training Corporation is soliciting bids for the installation of commercial-grade panic hardware on electrical room egress doors at the Centennial Job Corps Center in Nampa, Idaho. The project encompasses five specific locations: the Cafeteria, Men's Dorm, Women's Dorm, Recreation, and Vocational buildings. The scope of work requires the contractor to conduct site surveys, procure Grade I commercial-grade panic bars with matching exterior trim and door closers, and perform installations that ensure doors open outward under simple pressure. All work must comply with NEC 2023 Article 110.26(C)(3), NFPA 101 Life Safety Code, and the Americans with Disabilities Act. Final acceptance is contingent upon the successful completion of at least 10 consecutive cycle tests to verify fail-safe operation. This is a fee-for-service subcontracting opportunity set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certifications, under NAICS code 238290. Bidders must submit a lump sum bid sheet, a completed supplier packet including a W-9 and self-certification form, and three references for similar projects by December 1, 2026. The contract is subject to various Federal Acquisition Regulations, including Davis-Bacon Act prevailing wage rates for Idaho, minimum wage requirements under Executive Order 14026, and paid sick leave under Executive Order 13706. Awarded contractors must provide proof of insurance and adhere to strict government guidelines regarding information security and the protection of sensitive data.
Management & Training Corporation/Centennial Job Corps Center

POSTED

33 minutes ago

DEADLINE

in about 1 month
NAICS: 238290
New
SLED
Pauma Security Gate
Solicitation # 2026-27-06
Solicitation 2026-27-06 for the Valley Center Pauma Unified School District involves the fabrication and installation of automated, keypad-entry hinging steel security swing gates at entry and egress driveways in Valley Center, California. The project requires two powder-coated steel double swing gates, each 18 feet wide by 5 feet tall, and explicitly prohibits the use of chain link options. Key technical components include a mounted Knox switch with Fire Department filing, two entry remotes, gate hold timers, a mounted strobe detector for emergency vehicles, and a keypad similar to the Door King 1506-086. The contract value is capped at 1,000,000 dollars, and the award will be granted to the lowest responsive and responsible bidder. Eligible bidders must hold a California contractor's license C13 or C-61/D28 and comply with prevailing wage requirements and Department of Industrial Relations registration. The project mandates a payment bond for 100 percent of the total bid price and a DVBE participation goal of at least 3 percent. Required submissions include a comprehensive bid packet featuring non-collusion affidavits, Iran Contracting Act certification, and fingerprinting certifications. Performance must be coordinated with the Director of Maintenance and Operations, with work hours restricted to 7:00 am to 5:00 pm, Monday through Friday. Additionally, contractors must adhere to strict hazardous material standards and California Air Resources Board compliance, with the district maintaining the right to terminate the agreement upon 30 calendar days written notice.
Valley Center Pauma USD

POSTED

about 9 hours ago

DEADLINE

in 5 days
NAICS: 238290
New
SLED
Districtwide Elevator And Wheelchair Lift Service, Preventive Maintenance, And Repairs Maintenance Services
Solicitation # 27.004
The Hayward Unified School District is soliciting bids under solicitation number 27.004 for districtwide elevator and wheelchair lift service, preventive maintenance, and repairs. The selected contractor will be responsible for the systematic examination, maintenance, and repair of all owned or leased systems, including hydraulic, electrical, and mechanical components, to ensure they remain in safe and usable condition. This contract requires the provider to hold an active C-11 Elevator Contractor license from the State of California and comply with all local and state codes, including Title 24 of the California Code of Regulations. The award will be granted to the lowest responsive and responsible bidder based on the rates provided in the bid form. Performance of regular services typically occurs Monday through Friday during standard business hours, while emergency repairs must be available 24 hours a day, seven days a week. The contractor must provide a bid bond of at least 10 percent of the bid amount and subsequently provide payment and performance bonds upon award. Invoicing is conducted monthly, with a requirement that authorized materials be invoiced at no more than 15 percent above the vendor's cost. Key compliance requirements include paying prevailing wages per the California Labor Code, submitting to fingerprinting and felony conviction certifications, and maintaining a minimum one-year warranty on work. All contracts are governed by the laws of the State of California.
Hayward Unified School District

POSTED

about 10 hours ago

DEADLINE

in 20 days

General Info

NAICS

238290 - Other Building Equipment Contractors

Place of Performance

300 TANKER RD, CORAOPOLIS, PA, 15108, USA

Set-Aside

SBA

Documents

3

171ARW GPC Purchase Request - J.E. Adams Commercial Vacuum

PDF, High priority: read this firstspecifications
High

B317 Plans & Tech Specs - Construction of Gate and Concrete Breaker

PDF, High priority: read this firstspecifications
High

Carwash_Payport_Hull_example.jpg

JPG

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

5 updates
PhaseClosed
Posted

Combined Synopsis

Notice updated

Response deadline changed from Aug 24, 2018 to Aug 28, 2018. The notice description changed.

Notice updated

Response deadline changed from Aug 28, 2018 to Aug 31, 2018. The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W7NX Uspfo Activity Paang 171
Contacts1 person available
OfficeCORAOPOLIS, PA, 15108-4805, USA
Office AddressCORAOPOLIS, PA, 15108-4805, USA
Contacts
Michael W. BoydContract Specialist

Full Description

Show more
THIS REQUIREMENT IS FOR WASH RACK REPAIRS FOR THE 171ST ARW IN CORAOPOLIS (PITTSBURGH), PA. INSTRUCTIONS ARE AS FOLLOWS: 1) ITEMS REQUESTED ARE ADVERTISED AS BRAND NAME OR EQUAL. VENDORS PROPOSING ALTERNATE BRAND NAMES OR MODEL NUMBERS **MUST** BE APPROVED PRIOR TO RESPONSE DEADLINE. 2) ALL ITEMS UTILIZED ARE REQUIRED TO BE USA-MADE AND IN NEW CONDITION. REFURBISHED, USED, AND OTHER-THAN-NEW ITEMS WILL NOT BE ACCEPTED. 3) THIS RFQ IS BEING CONDUCTED ON A LOWEST-PRICE TECHNICALLY ACCEPTABLE (LPTA) BASIS. 4) INTERESTED VENDORS MUST BE REGISTERED AND ACTIVE IN THE SYSTEM FOR AWARD MANAGMENT (SAM) IN ORDER TO BE AWARDED. IF YOU ARE NOT REGISTERED IN SAM, PLEASE CONTACT ME FOR ASSISTANCE. (REF: FAR 52.232-33). 5) THIS IS A 100% SMALL BUSINESS SET-ASIDE. VENDORS MUST BE A SMALL BUSINESS UNDER THE SIZE STANDARDS OF NAICS CODE 238290. VENDORS NEED NOT BE REGISTERED UNDER 238290, HOWEVER THEY MUST BE UNDER THE APPLICABLE SIZE STANDARD OF $15.0M. (REF: FAR 52.219-6) 6) NAICS SIZE STANDARDS: https://www.sba.gov/contracting/getting-started-contractor/make-sure-you-meet-sba-size-standards/table-small-business-size-standards 7) VENDORS WILL BE PAID VIA WIDE-AREA WORKFLOW/ IRAPT. (REF: DFARS 252.232-7006) 8) A SITE VISIT IS NOT MANDATORY TO BE CONSIDERED FOR AWARD. A SITE VISIT IS SCHEDULED FOR WEDNESDAY, 22 AUGUST AT 10:00PM EST. TO ATTEND A SITE VISIT, VENDORS MUST SEND THE FOLLOWING TO ME BY TUESDAY, 21 AUGUST AT 3:00PM EST. LATE SUBMISSIONS WILL NOT BE ACCEPTED AND WILL RENDER VENDOR INELIGIBLE TO ATTEND THE SITE VISIT. NO EXCEPTIONS! (REF. FAR 52.237-1) a. Company Name b. Name of Representatives Attending c. DRIVERS LICENSE # and STATE of ALL Representatives Attending 9) INSTRUCTIONS FOR OFFERORS: QUOTES MAY BE SUBMITTED VIA THIS RFQ POST OR VIA EMAIL TO contact@example.gov. STATEMENT OF WORK Repair Wash Rack B317 PROJECT JLSQ182014 23 July 2018 1. SCOPE: The project requires all plant, labor, tools, materials, equipment, transportation and supervision to repair the wash rack in bldg. 317 at the 171st Air Refueling Wing in Coraopolis, PA. Contractor will complete all tests and certifications as required by Federal, State and Local laws. 2. LOCATION/SITE VISITS: This project is located at the Pennsylvania Air National Guard Base, 171st Air Refueling Wing, Pittsburgh International Airport, Coraopolis, Pennsylvania 15108-4217 building 205. A pre-bid meeting / site visit will be scheduled by 171 ARW Base Contracting office if required. 3. NORMAL HOURS OF OPERATION: Week 1: 7:00 AM - 4:00 PM, Monday thru Friday; Week 2: 7:00 AM - 4:00 PM, Tuesday thru Friday. Work coordination dates will be accomplished after contract award. 4. GENERAL DESCRIPTION OF WORK: This project is to remove all existing car wash related equipment in the mechanical room and wash bay at bldg. 317 and replace with "like" equipment, excluding: hot water tank and water softener system. This includes, but is not limited to: pumps, stand, tanks, hoses, wands and port hulls etc., in accordance to manufacturer's specifications and recommendations. Pumps are currently 3 phase 230/460 volts 5 HP. 1. Install 2 bay high pressure pumps, 5 HP, 3 phase motors to deliver 4.5 gpm @ 1200-1500 psi. Include low water cutoff protection and a thermostatic weep. Utilize a non-accumulating timer for activation. 2. Replace ceiling mount high pressure boom assemblies, stainless steel wand holders and mat clamps (both sides of bay). 3. Replace port hulls (no money) both sides. 4. Install 7 function + 1 stop rotary switch door assembly with push button for activation. 5. Install foam brush assembly with J-hooks and stainless steel wall mounted boom (both sides of bay). 6. Replace all high pressure hose and fittings required. 7. Test and adjust both garage doors to ensure proper operation. Provide a cost proposal for the options outlined below: *Option 1: remove and replace 91 gal hot water tank with like equipment *Option 2: remove and replace water softener system with like equipment *Option 3: remove and replace exterior car vacuum with like equipment 5. MATERIALS: Construction materials must meet all required NFPA and UL requirements. 6. SITE CLEAN-UP: Contractor shall clean immediate work area, removing any generated debris from the work site and subsequently disposing of debris off base. Contractor is required to secure all trash and debris in covered receptacles. Contractor shall report the disposal location as well as both volume and weight of debris removed from the base to meet environmental reporting requirements as required by law. 7. DELIVERABLES TO GOVERNMENT: Contractor shall provide (2) close-out binders at the conclusion of this contract. Binders shall contain all elements of repair/inspection that were accomplished. Binders shall also include copies of system reports, operator manuals, etc., as well as any additional recommendations of future repairs and associated costs. 8. UTILITIES: The Government shall provide at no cost to the Contractor reasonable amounts of water and electricity to support the contract. Hook up will be to existing electrical outlets and existing water shut off valves and will be the contractor's responsibility. Any contractor requirement to connect to the base water system will need to be coordinated through the CE project manager and will require a backflow prevention device. 9. MATERIAL & EQUIPMENT ACCOUNTABILITY: Notify the Contracting Office Representative (COR) prior to delivery of any material or equipment to the site. The contractor shall ensure someone is available to receive delivered materials and able to store them safely in an area to be coordinated with the COR. Any materials delivered without prior coordination and without having someone to take receipt, shall not be accepted and turned away. 10. SECURITY: Security Forces shall monitor the incoming and outgoing of work personnel during the duration of the project. All deliveries shall be coordinated with the COR to arrange for their entrance onto Base property. Contractor Vetting - Contractor shall provide a completed Wing Form 128 two weeks prior to start of work. 11. ESCORTS: A security briefing will be conducted prior to the start of the contract. All Contractor personnel shall have a minimum of one (1) form of photo identification with them at all times. A government representative will escort the contractor while on base unless a long term visitor request is processed through the base Security Forces Squadron for "unescorted access" privileges. For this project, CE will request "unescorted access" privileges for the contractor (and sub-contractors) working on this project. The Contractor shall complete the Wing Form 128 for all personnel working on base for this project. The information required includes full legal name, social security number, date of birth, gender, and race. Allow up to 2 weeks for the approval process. AMENDMENT LOG: AMENDMENT 001: The Site Visit for this requirement has been moved to Wednesday, 22 August at 10:00PM EST, and the quote deadline has been moved from Friday, 24 August at 3:00PM to Tuesday, 28 August 2018 at 3:00PM. Interested vendors who have already responded need take no further action, however interested vendors who have not responded will still need to respond with names and drivers license info of visitors planning to take part. All other terms and conditions remain unchanged AMENDMENT 002: Deadline has been extended from Tuesday, 28 August at 3:00PM to Friday, 31 August at 3:00PM. All other terms and conditions remain unchanged. AMENDMENT 003: Added Files "B317 PLANS & TECH SPECS", detailing all aspects of the building and equipment construction, and "B317 VACUUM", detailing vacuum specs. All other terms and conditions remain unchanged. AMENDMENT 004: Added additional clarification as follows: 1. We are NOT seeking to repair the eye wash stations in this building/requirement. They are operational. 2. Garage doors - testing and adjusting are all that is needed. The doors are wired as a dead-man closer, there is no stop sensor to stop them if there is an obstruction in the way. CE can re-connect the door to the trolley if that contractor will not do it - that should be a no cost item. It was just disconnected so no one would use the door. We will NOT be looking to upgrade doors OR wiring to comply with code - they are grandfathered in. All other terms and conditions remain unchanged. AMENDMENT 005: Added the following RFIs and responses: 1. Is the intent to replace the solution tanks and solution collection hoses as part of the project? ANSWER: Yes - the intent is to replace the solution tanks and solution collection hoses. 2. If it is more economical to replace the complete wash pump station over rebuilding the existing is this acceptable to the government? ANSWER: The government is looking to have a new wash pump station, not rebuilding the existing. 3. The wiring supplying power to the vacuum is ran in plumbing PVC. Is the intent to rework the PVC from where it comes out of the ground with electrical PVC as part of the replace vacuum option? ANSWER: Yes - replace existing PVC with electrical PVC where it comes out of the ground. 4. Please further explain the requirement to replace port hulls both sides? ANSWER: See picture of a payport hull. Government desires to have controls that do NOT require money. 5. The water supply valves for the wash pump system are extremely corroded. Is the intent to replace these? ANSWER: Yes - replace water supply valves for wash pump.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS