This Combined Synopsis/Solicitation opportunity from Department Of Homeland Security was posted on March 31, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Repair Galley Grease Trap and Holding Tank at USCG Station Yankeetown

Closed
30324PR260000002Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238220
New
SLED
Install Pier D High Pressure Air System, NSBREM-724-A
Solicitation # N4425527RB003
This is a Design-Build project to install a permanent high pressure air (HPA) system at Pier D, B724A of Naval Base Kitsap in Bremerton, Washington. The scope of work includes the design, construction, and commissioning of the system, specifically incorporating the existing HPA cross connection into a system supplied from the HPA compressors located on the south end of Pier D. The project requires the installation of shore risers at five specific locations (East bollards 11, 59, and 101, and West bollards 47 and 59) to provide access for homeports, with all new piping run under service grates and valves placed topside. The contract is a 100% set-aside for 8(a) businesses located within SBA Region X, covering Alaska, Idaho, Oregon, and Washington. The estimated magnitude of construction is between $1,000,000 and $5,000,000, with a period of performance of 538 calendar days from the date of award. The contract is a firm-fixed-price task under the 8(a) MACC, with award based on price and MACC past performance. Key requirements include adherence to Unified Facilities Criteria (UFC) and ASME codes, the submission of a Design Quality Control (DQC) Plan, and strict security protocols for base access and cybersecurity for facility-related control systems. Liquidated damages for delays are set at $500.00 per calendar day.
Bristol Alliance of Companies

POSTED

about 6 hours ago

DEADLINE

in 10 days
NAICS: 238220
New
Springdale JCC –Recreation HVAC Repair or Replacement
Solicitation # springdale-jcc-recreation-hvac-repair-or-replacement
The Career Systems Development Corporation is seeking quotes for the repair or replacement of two failed 25-ton AAON rooftop HVAC units (Model RH-25-2-00-222) at the Springdale Job Corps Center in Troutdale, Oregon. Bidders must submit two separate, itemized quotes—one for the repair of existing units and one for full replacement—along with a professional recommendation on the most suitable approach based on cost, unit age, and parts availability. Replacement quotes must be comprehensive, covering all necessary equipment and services including cranes, roof supports, curb adapters, and new thermostats. This solicitation is set aside for Small Business (SB), SBA certified Veteran Owned Small Business (VOSB), SBA certified Service-Disabled Veteran Owned Small Business (SDVOSB), SBA certified Women-Owned Small Business (WOSB), and SBA certified HUBZone Small Business (HUBZone SB). The project is subject to prevailing wage laws, with replacement work governed by Davis-Bacon Wage Determination OR20260100, R.1, and repair work governed by Service Contract Act Wage Determination 2015-5563, R.28. Bidders must provide an Oregon CCB contractor's license number and ensure quotes remain valid for 90 days from the closing date. For contracts valued at $100,000 or more, payment and performance bonds are required upon award. Warranty requirements include one year for parts and workmanship, and five years for the compressor and thermostat. The response deadline is December 11, 2026.
Career Systems Development Corporation

POSTED

about 6 hours ago

DEADLINE

in 19 days
NAICS: 238220
New
Los Angeles Job Corps- Sprinkler Head Repairs
Solicitation # LA JCC Lobby Sprinkler Repairs
Management & Training Corporation (MTC) is seeking a subcontractor to perform sprinkler repairs at the Los Angeles Job Corps center located at 1020 South Olive Street, Los Angeles, California. The scope of work involves the installation of one additional fire sprinkler head in the lobby area to extend existing coverage. The contractor must provide all labor, supervision, materials, and equipment, including the use of a man lift, and ensure the installation is connected to the existing system above the T-bar ceiling and compliant with applicable fire sprinkler standards. This is a small business set-aside opportunity open to SBA certified Veteran Owned Small Businesses, Service-Disabled Veteran Owned Small Businesses, Women-Owned Small Businesses, and HUBZone Small Businesses. The contract is governed by NAICS code 238220 and adheres to Service Contract Labor Standards under Wage Determination No. 2015-5613 Rev 31. Award will be based on a best value determination by MTC. To be considered, offerors must submit a bid sheet with a lump sum fee, a completed supplier packet including a W-9 and self-certification form, three references for similar projects, and proof of insurance. Invoices are to be submitted on a weekly or bi-weekly basis and must include a purchase order number and detailed pricing. All subcontractors are required to possess a Unique Entity Identifier (UEI) number.
Los Angeles Job Corps

POSTED

about 6 hours ago

DEADLINE

in 2 days
NAICS: 238220
New
MJCC Multiple HVAC Replacement System
Solicitation # mjcc-multiple-hvac-replacement-system
The Montgomery Job Corps Center, located in Montgomery, Alabama, is seeking quotes for a subcontracting opportunity to perform the turnkey replacement of multiple HVAC systems across various center buildings. The scope of work includes the installation of units ranging from 3.5 to 10 tons, with specific technical requirements for certain units such as Energy Star compliance, a minimum EER rating of 16, 90% efficiency furnaces, and the use of R-454B refrigerant. The project requires the contractor to employ a testing and balancing service to ensure airflow meets original designs and provide a 5-10 year warranty on equipment parts and a 2 year warranty on workmanship. This opportunity is set aside for Small Business (SB), SBA certified Veteran Owned Small Business (VOSB), SBA certified Service-Disabled Veteran Owned Small Business (SDVOSB), SBA certified Women-Owned Small Business (WOSB), and SBA certified HUBZone Small Business (HUBZone SB). Interested bidders must submit a completed bid sheet with a detailed cost breakdown, a proposed service schedule, Alabama licensing and credentials, certificates of insurance, and required vendor paperwork including Form W-9 and FFATA forms. All winning bidders must maintain an active SAM.gov registration and a Unique Entity ID. The project is subject to the Davis-Bacon Act, requiring prevailing wages and certified payroll records, and adheres to FAR clauses regarding debarment, the Service Contract Act, and anti-lobbying certifications. Bonding requirements vary by project value, with a 100% performance and payment bond required for projects exceeding $150,000. Bids must be submitted by November 27, 2026, at 12:00 PM CST, and must remain valid for 90 days. Education & Training Resources (ETR) will serve as the sole judge for the subcontract award.
Montgomery Job Corps Center

POSTED

about 6 hours ago

DEADLINE

in 6 days
NAICS: 238220
New
Joliet Job Corps-Request for Quote HVAC Replacement Female Dormitory
Solicitation # joliet-job-corps-request-quote-hvac-replacement-female-dormitory
Management & Training Corporation (MTC) is soliciting bids for a fixed-price, single lump sum subcontract to replace the HVAC systems at the Joliet Job Corps Center in Illinois. The project scope involves the removal and disposal of existing equipment and the installation of ten new Carrier furnace and air conditioning systems, along with the integration of a Pelican Building Automation System (BAS) across eleven units. The estimated contract value ranges from $250,000 to $500,000. This opportunity is set aside for Small Business (SB), SBA certified Veteran Owned Small Business (VOSB), SBA certified Service-Disabled Veteran Owned Small Business (SDVOSB), SBA certified Women-Owned Small Business (WOSB), and SBA certified HUBZone Small Business (HUBZone SB). Bids will be evaluated based on overall best value, and a physical site visit is required prior to submission. For bids equal to or greater than $25,000, a bid bond of 20% of the base bid is required, and the awarded contractor must provide performance and payment bonds from a surety company with at least an A- rating. The contract is subject to the Davis-Bacon Act, requiring compliance with specific Illinois wage determinations and the submission of certified payroll reports. Additionally, contractors must provide proof of general liability insurance with a minimum limit of $1,000,000 and worker's compensation insurance with employer's liability limits of at least $500,000. All bids and required documentation must be submitted to Frances J. McGraw by November 23, 2026.
Joliet Job Corps

POSTED

about 6 hours ago

DEADLINE

in 2 days
NAICS: 238220
New
Centennial Dry Sprinkler System & Compressor Replacement Services
Solicitation # centennial-dry-sprinkler-system-compressor-replacement-services
Management & Training Corporation is seeking bids for a fixed-price, single lump sum contract to provide dry-type sprinkler system and compressor replacement services at the Centennial Job Corps Center in Nampa, Idaho. The project scope involves eliminating system leaks and replacing failing infrastructure and compressors in the Men's Dormitory (Building CM), Women's Dormitory (Building CW), and Recreation building (Building D). All work must adhere to NFPA 25 (2023 Edition) and local, state, and national codes. Key deliverables include the demolition and removal of existing distribution piping and compressors, followed by rigorous leak testing and operational commissioning to ensure the system does not short-cycle. This opportunity is set aside for HUBZone, Woman-owned, and Service-Disabled Veteran-owned small businesses. Bids are due by December 1, 2026, and must include a detailed cost breakout and proof of insurance. A physical site visit is mandatory prior to bid submission. For bids totaling $25,000 or more, a bid bond of 20% of the base bid is required, and the awarded contractor must provide performance and payment bonds. The contract is subject to union prevailing wage rates per Idaho wage determination ID20250106 and requires compliance with various FAR clauses, including debarment disclosure for first-tier subcontractors exceeding $45,000. Award decisions will be based on overall best value.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 6 hours ago

DEADLINE

in 10 days
NAICS: 238220
New
Dep’t of Labor – Indoor sprinkler system replacement/work
Solicitation # SH26-XXX
The Shriver Job Corps Center is soliciting a single lump sum contract for the replacement and repair of the indoor fire sprinkler system in Building B in Devens, Massachusetts. The project is necessary because the building has been inaccessible for several years, and winter weather has damaged the sprinkler pipes. The scope of work includes replacing the alarm valve, test and drain valves, couplings, and sprinklers, as well as repairing branch lines and performing system integrity tests. This is a small business set-aside available to SBA certified Veteran Owned Small Businesses, Service-Disabled Veteran Owned Small Businesses, Women-Owned Small Businesses, and HUBZone Small Businesses. Award will be based on best value rather than the lowest price. Proposals must be submitted on official company letterhead and include a detailed cost breakdown, a timeline for substantial completion, and a list of materials including MSDS. Required documentation includes a valid Massachusetts Contractor's License, insurance certificates, and certification of conformance to the latest wage rate decisions. The contract is subject to the Davis-Bacon Act and requires adherence to EPA and OSHA regulations, with Massachusetts state regulations prevailing if they are more stringent. Final acceptance requires a hydrostatic test, a main drain test, and an affidavit from a fire protection company confirming system integrity.
Shriver Job Corps

POSTED

about 6 hours ago

DEADLINE

in 17 days
NAICS: 238220
New
Inland Empire Job Corps-Request for Quote HVAC Replacement Cafeteria & OA CTS
Solicitation # inland-empire-job-corps-request-quote-hvac-replacement-cafeteria-oa-cts
Management & Training Corporation (MTC) is seeking a subcontractor for a fixed-price, single lump sum contract to replace HVAC systems at the Inland Empire Job Corps center in San Bernardino, California. The project involves furnishing and installing new packaged HVAC units with gas heating at the Cafeteria and OA/CTS locations, including the recovery of refrigerant per EPA regulations and the disposal of old units. The estimated price range for the project is between $25,000 and $100,000, with a performance period of 60 consecutive business days following the Notice to Proceed. Bids are due by November 23, 2026, and will be evaluated based on overall best value. This opportunity is a set-aside for Small Business (SB), SBA certified Veteran Owned Small Business (VOSB), SBA certified Service-Disabled Veteran Owned Small Business (SDVOSB), SBA certified Women-Owned Small Business (WOSB), and SBA certified HUBZone Small Business (HUBZone SB). Key requirements include compliance with California prevailing wage determinations, OSHA safety standards, and the provision of bid, performance, and payment bonds for bids of $25,000 or more. Offerors must submit a detailed cost breakout on company letterhead and complete the MTC Supplier Self-Certification packet, including a W-9 and UEI number.
Inland Empire Job Corps

POSTED

about 6 hours ago

DEADLINE

in 2 days
NAICS: 238220
New
CBP7792 Cafeteria Hot Water Heater Replacement
Solicitation # CBP7792
Management & Training Corporation (MTC) is seeking bids for a subcontracting opportunity to replace the cafeteria hot water heater at the Sierra Nevada Job Corps Center in Reno, Nevada. This is a fixed-price, single lump sum contract with an estimated value between $25,000 and $100,000. The scope of work requires the contractor to provide all labor, materials, and equipment to dispose of an existing failing commercial natural gas-fired water heater and install a new 125-gallon commercial-grade natural gas-fired water heater. To minimize cafeteria disruptions, all utility-interrupting activities must be performed during approved off-hours, such as weekends or evenings after 8:00 PM. This opportunity is set aside for Small Business. Bids will be evaluated based on overall best value, considering price, quality, delivery schedule, and relevant experience. Bidders must provide a detailed cost breakout, proof of insurance, and three references. For bids equal to or greater than $25,000, a bid bond of 20% of the base bid is required, and the awarded contractor must provide performance and payment bonds from an A-rated surety company. The project must comply with federal, state, and local codes, Department of Energy energy-efficiency requirements, and Davis-Bacon Act wage determinations for Washoe County. Bids are due by November 25, 2026.
Sierra Nevada Job Corps Center

POSTED

about 6 hours ago

DEADLINE

in 4 days

AI Contract Overview

Show more

The contract issued by the U.S. Coast Guard involves repair work on the galley grease trap and holding tank at the USCG Station Yankeetown in Florida. It is a total small business set-aside under NAICS code 238220 for plumbing, heating, and air-conditioning contractors. The project requires the contractor to provide all supervision, labor, materials, and equipment needed to remove the existing grease trap and cracked holding tank, dispose of them properly, and install new septic tanks, a grinding station, panel, dosing system, and a drain field. Work must begin no later than 10 days after the notice to proceed, and the contractor is responsible for coordinating site access, obtaining necessary permits, and providing temporary bathroom and shower facilities. The contract is firm-fixed-price with a maximum value of $82,500 and proposals are due by April 13, 2026. Award will be based on the lowest price technically acceptable or best value criteria, considering technical capability, past performance, and price reasonableness. Contractors must comply with OSHA safety regulations, environmental laws including NEPA and EPA standards, as well as Davis-Bacon wage requirements. Security and operational protocols are strict; only U.S. citizens or permanent residents may work onsite, and all personnel and equipment are subject to inspection. The contractor must provide a site-specific safety plan, ensure proper disposal of waste offsite, and warrant the work for one year following substantial completion. Final acceptance requires a Quality Assurance Evaluator inspection and correction of any deficiencies within five business days.

General Info

USCG contract for grease trap repair, septic installation, $82,500 max, must comply with regulations.

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors

Place of Performance

FL, 34434, USA

Set-Aside

SBA

Documents

3
PDF, High priority: read this firstcombined-synopsis-solicitation
High
PDF, High priority: read this firstsow
High
PDF, High priority: read this firstwage-determination
High

Read all 3 documents

Every page of every file, in your free workspace.

Read the documents

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

View Full Breakdown

This one is closed. Find the next one like it.

Open contracts like this one, right now:

  • Install Pier D High Pressure Air System, NSBREM-724-AOpen now, due in 11 days
  • Springdale JCC –Recreation HVAC Repair or ReplacementOpen now, due in 20 days
See open contracts like this

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Homeland Security → Base MIAMI(00028)
Contacts1 person available
OfficeMIAMI, FL, 33132, USA

Full Description

Show more

COMBINED SYNOPSIS/SOLICITATION


Repair Galley Grease Trap and Holding Tank at USCG Station Yankeetown


1. General Information


Solicitation Number: 30324PR260000002


Date Posted: 03/31/2026


Response Due Date: Monday April 13, 2026, at 11:00AM EST
 


NAICS Code: 238220 Plumbing, Heating, And Air-Conditioning Contractors
 


Set-Aside: Total Small Business Set a Side
 


Contracting Office: USCG PROCUREMENT & CONTRACTINNG
12100 SW 152ND ST
MIAMI, FL 33177
Point of Contact: Mehdi Bouayad
Email: Sign up to see this detail
Sign up to see this detail

 


2. Description of Work
 


This is a combined synopsis/solicitation for construction services prepared in accordance with FAR Part 36 and FAR Part 13. The U.S. Government intends to award a firm-fixed-price contract based on the lowest price technically acceptable (LPTA) or best value tradeoff method.
 


Scope of Work:
1. GENERAL REQUIREMENTS: The work consists of providing all supervision, labor, materials, and equipment required to: repair galley grease trap and holding tank. USCG STA YANKEETOWN.

 


2. COMMENCEMENT AND COMPLETION OF WORK: Upon acceptance the contractor shall commence work NLT 10 days after notice to proceed.
 


3. SCOPE OF WORK:
• Prior to commencement of work contractor shall notify MK1 John Piskura Sign up to see this detail to coordinate removal of obstacles within the facility and provide site access.
• Contractor shall acquire all permits required by state and local authorities .
• Contractor shall provide temporary 4 bathroom and shower facilities during duration of project.
• Contractor shall pump out and remove existing grease trap and cracked holding tank and dispose of IAW environmental requirements.
• Contractor shall install new grinding station and panel.
• Contractor Shall Install new Installation of a new drain field up to 1395 sq ft LPD
• Contractor shall Install 1 new 2000 Gallon Septic Tanks Single Compartment in Test and verify the operation of the septic system prior to conclusion of work in the presence of the Quality Assurance Evaluator (QAE)
• Contractor shall Install of 1 new 1050 GallonSeptic Tank Single Compartment in series.
• Contractor shall install Installation of New Dosing system 1 new 1900 Gallon Dosing tank, 2 new low pressure dosing pumps, new alarm and alternating panel.
• Contractor shall install fill dirt if permit requires.
• Contractor shall remove Parking Lot Removal 3' x 50' area for installation TBD if existing pipe underneath requires replacement.

 


Location of Project: U.S. Coast Guard Station Yankeetown
5800 Riverside Dr. Yankeetown, FL 34434.

 


Examination of Site: It is HIGHLY ENCOURAGED that bidders carefully inspect the
workplace and verify all work necessary to complete job. Prospective bidders arrange for a tour
of the job site by calling the point of contact, MK1 John Piskura at Sign up to see this detail or via email Sign up to see this detail

 


Site Visit Highly Recommended but not Mandatory *************** Tuesday April 07, 2026 at 10:00AM EST*****************
 


Site Visit Coordinator is MK1 John B. Piskura Email: Sign up to see this detail Phone: Sign up to see this detail
 


1. Continuity of Facilities Operation:
Schedule work to minimize interference with the facility operations and during the normal
operating hours of 7:00 am to 3:00 pm Monday through Friday, excluding federal holidays. Work
may be conducted during other hours if approved in advance by coordinating with the facility
Point of Contacts (POC) listed below.

 


2. Notification of Start and Completion of Work:
The Contractor shall provide a simple and general schedule of work. For example, “Begin work
at ____ on _______. Work is expected to last __ days and be complete on _______.”

 


3. Coast Guard Points of Contact:
The Contractor shall coordinate with the following personnel to arrange access the facility.

 


POC’s are listed in order of preference.
Name Email / notes Phone Number
MK1 John B. Piskura Email: Sign up to see this detail Phone: Sign up to see this detail

 



4. Recycling and Disposal of Refuse:
Minor refuse and waste materials resulting from operations may be disposed of at Air Station Miami.
All disposals shall be done in accordance with federal, state, and local
laws and regulations. No Hazardous Waste or bulk waste may be disposed of in Air Station
Miami dumpsters.

 


5. Safety:
During the execution of this contract, the Contractor shall conform to the rules and regulations as
set forth by OSHA State and Federal regulations. Immediate notification to the Contracting
Officer’s Representative of lost time due to accidents is required. Provide two copies of
Workman’s compensation accident reports by noon of the day following the accident. The Coast
Guard reserves the right to bar any workers or supervisors from the premises should they be
documented as violating set safety standards and regulations.

 


6. Inspection:
The Contracting Officer’s Representative has the right to reject defective workmanship or
materials or work not performed as per the contract specifications.

 


7. Operations and Storage:
The Coast Guard has no responsibility for receipt, storage, or protection of contractor’s
materials. The Coast Guard will not accept shipments, and no materials may be stored on site
by the contractor. The contractor is responsible for the protection of existing structures and utilities
and vegetation. Any damage shall be repaired at the contractor’s expense.

 


8. Utilities:
Contractors are authorized to use Station Yankeetown power and water while conducting the
work efforts outlined in this document. Any other use of power is not authorized. The unit POC’s
listed above will designate available utility connection points if necessary.

 


9. General Regulations while onboard Station Yankeetown.
1. Daily colors and the raising/lowering of the American flag will take place every morning
at 0800 and every evening at sunset. All personnel on Base will face the main flagpole &
maintain silence and all vehicles & equipment will halt during these brief events.
2. Traffic Regulations:
a. 10 mph speed limit
b. No use of cell phones is permitted while driving vehicles or operating heavy
machinery.
c. All personnel shall obey all marked traffic signals including stop signs &
stoplights.

 


5. Notice shall be given to the Coast Guard’s representative 1 week in advance of any
planned outages, including any pool closure and expected duration.
6. Contractors are welcome to utilize the restrooms in the area they are currently working in
providing they are clean and do not track mud, dirt or any other debris into the
restrooms.

 


6. No personnel other than the Contracting Officer has the authority to alter the terms of any
contract or to issue any change orders. Accordingly, the contractor shall not complete
any work that would incur additional costs to the government without written approval
from the Contracting Officer.


10. SECURITY REQUIREMENTS:
 


1. The contractor shall provide a consolidated list of all contractor personnel who will be
working on Station Yankeetown at least 2 days prior to work. This is for
routine/ standard background checks of all personnel entering the base. Information
required is full name, date of birth, and last 4 digits only of Social Security Number.

 


2. Only American citizens and permanent resident aliens are allowed onboard Station Yankeetown Facilities. Absolutely no foreign nationals are permitted on the premises.
Appropriate identification shall be provided at the front gate to attain base entry.

 


3. All contractor vehicles, equipment and gear onboard Coast Guard properties are subject
to search, at all times. Additionally, at all times due to security and operational needs, the
contractor is subject to orders to evacuate the property at any time.

 


4. Absolutely no firearms or weapons of any kind are allowed onboard CG Station Yankeetown.
 


5. The contractor and subcontractor personnel shall wear company identification and
always carry photo identification on their person. Personnel shall not stray from the
immediate area of work nor direct avenues of ingress and egress unless authorized in
advance.

 


Contractor shall be responsible for the removal of all trash and debris from project area off site
upon completion.
All work must be approved by the Contracting Officer’s Representative.
Warranty:
The Contractor warrants that all workmanship shall be free from defects for a period of one years
from the date of substantial completion.

 


12. ACCEPTANCE OF WORK:
When the contractor has completed all work, they shall notify the Coast Guard (COR) for a final
inspection with least a 24-hour notice. If there are any project discrepancies noted, they shall be
corrected within 5 business days of discovery. The work will be accepted as complete upon
verified correction of any/ all noted discrepancies. After work acceptance, the contractor shall
submit final invoice to the Coast Guard as directed by the COR.

 


Magnitude of Construction:
Not to exceed $82.5K

 


3. Submission Details
 


Proposals Due By: Monday April 13, 2026/11AM EST
 


Submission Method: [Email Sign up to see this detail or Mailed Bids]
 


Technical Proposal (demonstrating capability and experience).
Price Proposal (detailed cost breakdown).
Past Performance References will be reviewed

 


Evaluation Criteria
Award will be made based on [Lowest Price Technically Acceptable (LPTA) / Best Value] criteria. Proposals will be evaluated on:
1. Technical Acceptability – Demonstrated experience in similar projects.
2. Past Performance – Positive references from previous construction work.
3. Price Reasonableness – Competitive pricing aligned with market rates.
6. Contract Terms and Conditions

 


This procurement is subject to the following:
Davis-Bacon Act Compliance: Wage Rates FL20260019 Revised on 01/02/2026
FAR Clauses 52.236-2 (Differing Site Conditions), 52.236-3 (Site Investigation), 52.236-5 (Material and Workmanship), 52.236-7 (Permits and Responsibilities).
Other federal, state, and local regulations governing construction contracts.

 


7. Inquiries
*****All questions regarding this solicitation must be submitted in writing to John Piskura no later than Thursday April 9, 2026 COB.*********

 


Issued By:
Contracting Officer Mr. Mehdi Bouayad
United States Coast Guard

 


8. Additional Clauses and Provisions
8.1 Safety and Health Requirements
The contractor shall comply with:
• Occupational Safety and Health Administration (OSHA) Standards (29 CFR 1926) for construction safety.
• U.S. Army Corps of Engineers Safety Manual EM 385-1-1, if applicable.
• Submission of a Site-Specific Safety Plan (SSSP) within [X] days after award.
• Implementation of Personal Protective Equipment (PPE) and safety measures for workers on-site.
8.2 Environmental and Sustainability Requirements
• The contractor shall comply with National Environmental Policy Act (NEPA) and all EPA regulations.
• Use of environmentally preferable products and materials in accordance with FAR 23.1 (Sustainable Acquisition Policy).
• Proper disposal and handling of hazardous materials per Resource Conservation and Recovery Act (RCRA).
• Stormwater Pollution Prevention Plan (SWPPP) implementation (if applicable).

 


8.3 Compliance with the Davis-Bacon Act
For contracts over $2,000, the contractor shall comply with the Davis-Bacon Act (40 U.S.C. 3141–3148):
• Submit certified payroll reports weekly.
• Pay laborers and mechanics at least the prevailing wage rates specified in the wage determination.

 


8.4 Delays and Liquidated Damages
• If the contractor fails to complete work by the agreed deadline, the Government may impose liquidated damages of $[X] per calendar day of delay.
• Delays due to unforeseen conditions (e.g., weather, force majeure) must be reported within 24 hours and documented.

 


8.5 Subcontracting Limitations
• In accordance with FAR 52.219-14, at least 15% of the contract value must be performed by the prime contractor (for general construction).
• Subcontractors must be pre-approved, and the prime contractor remains liable for their compliance.

 


8.6 Material and Workmanship Standards
• All materials shall conform to industry standards (ASTM, ANSI, etc.) and be subject to Government inspection.
• The Government reserves the right to reject defective work and require rework at contractor’s expense.

 


8.7 Bonding and Insurance Requirements
• For contracts over $150,000, performance and payment bonds are required per FAR 28.102-1.
• Contractors shall maintain liability insurance in the following amounts:
o General Liability: $1,000,000 per occurrence.
o Workers’ Compensation: As required by state law.
o Automobile Liability: $500,000 per accident.

 


8.8 Inspection and Acceptance
• Work will be inspected by the Contracting Officer’s Representative (COR).
• The Government reserves the right to reject non-conforming work and withhold payment until deficiencies are corrected.

 


8.9 Buy American Act Compliance
• Materials must comply with the Buy American Act (FAR 52.225-9) unless an exemption is approved.

 


8.10 Dispute Resolution and Claims
• Disputes shall be handled per FAR 52.233-1 (Disputes Clause).
• The contractor must attempt to resolve disputes through negotiation before escalating to formal claims.

Get AI-powered intelligence on the opportunities still open

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS