This Sources Sought opportunity from Department Of Defense was posted on December 29, 2016. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Repair Main Sewer Line

Closed
F2MRAA6348AW01Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237110
New
Morgans Branch Force Main and Pump Station Improvements
Solicitation # SRP-W-134-0290
The Morgans Branch Force Main and Pump Station Improvements project, solicitation number SRP-W-134-0290, is a construction contract for the City of Belmont in North Carolina with a project estimate of 16,690,000 dollars. The scope of work involves the construction of 16,435 linear feet of new 20-inch ductile iron force main and comprehensive upgrades to the Morgans Branch Pumping Station. Key infrastructure improvements include the installation of a new wet well, valve vault, and associated appurtenances, as well as the demolition of existing pumps and piping. The contractor is responsible for delivering a fully operational station featuring mechanical and electrical systems, including pumps, a generator, and odor control equipment, along with new gravity sewers and manholes. The contract is a small business set-aside and will be awarded to the responsible bidder submitting the lowest responsive bid. Bids must be submitted using the EJCDC C-410 form and include a bid bond, evidence of signing authority, and MWBE compliance documentation. Performance and payment bonds are required upon award. Project administration follows EJCDC standard general and supplementary conditions, with payments processed monthly via applications for payment reviewed by the Engineer. Final acceptance is contingent upon a substantial completion inspection, the resolution of a punch list, and a final inspection conducted by the Owner, Contractor, and Engineer.
Don Moorhead Construction, Inc.

POSTED

about 6 hours ago

DEADLINE

in 21 days

General Info

NAICS

237110 - Water and Sewer Line and Related Structures Construction

Place of Performance

Joint Base San Antonio - Lackland, SAN ANTONIO, TX, 78236, USA

Set-Aside

NONE

Documents

1

Sources_Sought_FBO_Attachment.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA3016 502 Cons Cl
Contacts2 people available
OfficeJBSA LACKLAND, TX, 78236-5286, USA
Office AddressJBSA LACKLAND, TX, 78236-5286, USA
Contacts
Karen DeLorenzoContract Specialist
Michael BrownContracting Officer

Full Description

Show more
The 502d Contracting Squadron, Joint Base San Antonio-Lackland, Texas is conducting market research to identify potential sources that may possess the expertise, capabilities, and experience to repair a 30 inch sewer main and install a new manhole. This is not a Request for Proposal, rather a market research method to determine the availability businesses for a potential Firm-Fixed Price type contract. NO AWARD will be made from this Sources Sought posting. The required work will include providing all personnel, equipment, supplies, transportation, tools, materials, supervision and other items necessary to perform all operations required in the Project. The work to be accomplished includes: 1. Remove and store, for reuse, parking lot fencing. 2. Bypass and control sewage flow during construction. Meter flow while bypass is in operation and submit to government recorded flow rates when bypass operation is complete. 3. Reroute traffic in accordance with TxDOT requirements and IAW section 01 14 00 WORK RESTRICTIONS. 4. Excavate, remove, and replace the first 50' of main sewer RCP and corresponding materials from the MH 20-510 connection out towards MH 21-04. 5. Fill excavation site and repair the affected road, parking lot, curbs, and ground to their pre- existing conditions before ground erosion. Compact soil areas to merge with areas natural drainage slope. Immediately protect exposed soils from erosion with an approved method IAW specification section 01 35 35 ENVIRONMENTAL PROETECTION. 6. Structurally repair manholes MH 20- 510 and MH 21-04 using an approved Cementitious Repair Method (CRM). Stop infiltration using appropriate products and methods (injection grout/hydraulic cement). Fill holes, joints, honeycombs and around pipe penetrations with a Cementitious Repair Material as needed. Use ASTM 1216-09, Appendices X1-X7 to determine the thickness of Protective Coating Material (PCM), to apply. Apply PCM according to manufacturer recommendations. 7. Design, and install a new precast concrete manhole IAW section 33 30 00 SANITARY SEWERS. 8. Install approximately 700 linear feet of 30" diameter Cured-In-Place Pipe (CIPP) in the existing sewer line from MH 20-510 to MH 21-04 with structural fiberglass liner using UV cured CCIP process. Contractor to submit product data ten days after NTP. 9. Repair fencing that was damaged by the shifting soil caused by the sinkhole. The magnitude of construction for this project is $250,000 and $500,000. Please return the attached survey to karen.delorenzo@us.af.mil no later than noon (Central Standard Time) on 16 January 2017.

More opportunities from Department Of Defense → FA3016 502 Cons Cl

Same awarding agency

NAICS: 238210
New
Federal
DCF3 PROJECTION SYSTEM
Solicitation # A070977
The Department of Defense, specifically the 502 Cons Cl under the Office of the Air Force, is issuing a sources-sought Request for Information (RFI) for the DCF3 Projection System, solicitation number A070977. The objective is to identify capable providers for the installation of standalone audio-visual (AV) classroom equipment in sixteen classrooms at the BMT DCF3 (Building 9270) located at JBSA-Lackland, Texas. The scope of work includes providing all personnel, equipment, and materials to install laser projectors, zoom lenses, lecterns, scaling switchers, and associated cabling. The system must operate as a standalone solution and is strictly prohibited from interfacing with the Air Force network. Key deliverables include the integration of Apple Government-Furnished Equipment, the provision of technical documentation, and the delivery of user training for staff. Technical requirements specify that projectors and extension columns must be Trade Agreement Act (TAA) compliant, and touch panels must be FCC Class A certified. The contractor is responsible for ensuring high video resolution and sound quality, with final acceptance based on a post-installation walkthrough and inspection at the project site. Security requirements are stringent, requiring criminal history checks and background investigations for all personnel accessing the base, as well as strict adherence to Force Protection Condition procedures and a total prohibition of weapons on site. This RFI is strictly voluntary and is not a formal solicitation for quotes; interested parties must submit their capabilities and open-market pricing via email to Tommie Low by October 27, 2026, at 10 a.m. CST.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

about 24 hours ago

DEADLINE

in 7 days
View Details
NAICS: 811310
New
Federal
Aviation Support Equipment Load Testing
Solicitation # F2MT2M6146AQ01
This Sources Sought Notice, solicitation number F2MT2M6146AQ01, is a market research effort to identify qualified sources capable of providing aviation support equipment load testing and maintenance for the 433rd MXS/AMXS at Joint Base San Antonio-Lackland, Texas. The scope of work involves non-personal services including annual preventive maintenance inspections, load tests, certification, and both scheduled and unscheduled repairs to ensure the safe operation of aircraft support equipment. All services must adhere to OSHA Standards 1910 and 1926, ANSI Standards B30.16 and B30-5, and applicable Air Force Instructions and Technical Orders. Key deliverables include an initial annual preventive maintenance schedule, certification reports due within two workdays of completion, and repair estimates provided within 48 hours of an initial survey. Performance requirements specify that standard preventive maintenance must be completed and equipment returned within 48 hours of pickup, while approved repairs must be returned within three business days. Interested vendors must submit their response, including company details, CAGE code, and a statement of capability with product literature, to Dalwyn Corporan-Polanco by 10:00 AM CDT on October 20, 2026. This notice is for research purposes only and does not constitute a solicitation or a promise to issue one.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

5 days ago

DEADLINE

in about 3 hours
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS