Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on June 13, 2016. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Repair Sanitary Sewer Deficiencies, Phase 3

Awarded
FA4855-16-B-0004Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237110
New
Morgans Branch Force Main and Pump Station Improvements
Solicitation # SRP-W-134-0290
The Morgans Branch Force Main and Pump Station Improvements project, solicitation number SRP-W-134-0290, is a construction contract for the City of Belmont in North Carolina with a project estimate of 16,690,000 dollars. The scope of work involves the installation of 16,435 linear feet of 20-inch ductile iron force main and extensive upgrades to the Morgans Branch Pumping Station. Key deliverables include the construction of a new wet well and valve vault, the installation of pumps, a generator, odor control equipment, mechanical and electrical systems, and the demolition of existing pumps and piping. The project also encompasses site improvements such as stormwater facilities, fencing, and various paving and restoration activities. The contract will be awarded to the responsible bidder submitting the lowest responsive bid, with specific requirements for the submission of a Good Faith Efforts Form and Table A to meet MBE/WBE participation goals of 10.9 percent for the EPA and 10 percent for the State of North Carolina. Performance and payment bonds, as well as proof of insurance, are required. The project is managed by Willis Engineers, and the contractor will be subject to liquidated damages of 1,000 dollars per day for failure to achieve substantial completion. Payment is processed via Applications for Payment, with funds becoming due 30 days after presentation to the owner. All work must adhere to strict quality standards, including AWWA Specification C-600 for pipelines and NEMA standards for motors.
Don Moorhead Construction, Inc.

POSTED

about 3 hours ago

DEADLINE

in 21 days

AI Contract Overview

Show more

Contract FA4855-16-B-0004, titled Repair Sanitary Sewer Deficiencies, Phase 3, is a sealed bid solicitation issued by the Department of Defense for work at Cannon Air Force Base in Clovis, New Mexico. The project is 100 percent set aside for small businesses with an estimated value between 250,000 and 500,000 dollars. The scope of work involves the rehabilitation of the sanitary sewer system in sub-basin 1, specifically including the rehabilitation of 52 manholes, CCTV inspection of 1,130 linear feet of sewer pipe, and the repair of four sanitary cleanouts to mitigate storm water inflow and infiltration. The required period of performance is 120 calendar days following the notice to proceed, with deliverables including as-built drawings, O&M manuals, and GIS data. The contract is governed by strict general requirements and safety regulations, including AFOSH standards, utility clearance processes via AF Form 103, and specific fire and safety certifications. Technical specifications cover various divisions such as concrete, earthwork, and utilities, with a specific amendment adding specifications for section 03 01 32A. Labor is subject to prevailing wage rates and fringe benefits for heavy construction in Curry County, New Mexico, as outlined in the applicable wage determinations. Project administration is managed by the 27th Special Operations Civil Engineer Squadron, with requirements for detailed material submittals and shop drawings tracked via AF Form 66.

General Info

Contract Value

$469,246.62

NAICS

237110 - Water and Sewer Line and Related Structures Construction

Place of Performance

Cannon AFB, NM 88103, CLOVIS, NM, 88103, USA

Set-Aside

NONE

Award Issued Date

Documents

12

AF Form 66 - Schedule of Materials Submittals - Repair Sanitary Sewer I-1 Def. PH3

PDF, High priority: read this firstspecifications
High

Attachment 3 - General Requirements 01 01 00

PDF, High priority: read this first244 pages · specifications
High

Attachment 3 - General Requirements (FA855-16-B-0004)

PDF, High priority: read this firstspecifications
High

Cannon AFB Repair Sanitary Sewer Deficiencies Phase 2 - Project Manual

PDF, High priority: read this firstspecifications
High

CZQZ14-0554 Repair Sanitary Sewer Deficiencies, PH III - SOW

PDF, High priority: read this first4 pages · sow
High

FA4855-15-B-0013 Attachment 2 - AF Form 66

PDF, High priority: read this first2 pages · specifications
High

FA4855-15-B-0013 Attachment 5 - New Mexico Wage Determination

PDF, High priority: read this first4 pages · wage-determination
High

FA4855-16-B-0004 Amendment 0001

PDF, High priority: read this firstamendment
High

FA4855-16-B-0004 Repair Sanitary Sewer Deficiencies, Phase 3

PDF, High priority: read this firstifb
High

NM Wage Determination NM160007 - Heavy Construction

PDF, High priority: read this firstwage-determination
High

Project 000000000240733 - Civil Deficiencies Phase 3 Drawings

PDF, High priority: read this first8 pages · specifications
High

Project CZQZ140554 Repair Sanitary Sewer Deficiencies PH-3 Q&A

PDF, Low priorityq-and-a
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

2 updates
PhaseAwarded
Posted

Presolicitation

Notice updated

Response deadline added: Apr 22, 2016. The notice description changed.

Notice updated

Response deadline changed from Apr 22, 2016 to Apr 27, 2016. The notice description changed.

Type Changed

Presolicitation → Solicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA4855 27 Socons Lgc
Contacts2 people available
OfficeCANNON AFB, NM, 88103-5321, USA
Office AddressCANNON AFB, NM, 88103-5321, USA
Contacts
Bryian K. PhillipsContract Administrator
Dalton T. LanningContracting Administrator

Full Description

Show more
The purpose of this amendment is to add the Specifications with the 03 01 32"A" section as indicated in the Questions and Answers.

More opportunities from Department Of Defense → FA4855 27 Socons Lgc

Same awarding agency

NAICS: 562910
New
Federal
Small Arms Firing Range (SAFR) Cleaning and Maintenance Services
Solicitation # FA485526Q0078
Solicitation FA485526Q0078 is a combined synopsis and request for quotation for a firm-fixed-price contract to provide cleaning and maintenance services for Small Arms Firing Ranges at Cannon Air Force Base, New Mexico. This total small business set-aside under NAICS 562910 covers the 27th Special Operations Security Forces Squadron and 26th Special Tactics Squadron Combat Arms Training and Maintenance facilities. The scope of work requires quarterly inspections and cleaning of bullet traps, HVAC systems, dust collection units, and firing point areas, with a specific focus on the removal of lead dust and fragments. All services must be performed in accordance with manufacturer specifications and federal standards, including OSHA and EPA regulations. The contract structure consists of a base year running from November 1, 2026, to October 31, 2027, with four subsequent one-year option periods. Award will be granted to the responsible offeror determined to be most advantageous based on technical capability, past performance, and price. Offerors must submit a completed pricing worksheet, offeror certification, and conflict of interest statement by the response deadline of October 23, 2026. Payment will be processed electronically through the Wide Area WorkFlow system. Special requirements include strict adherence to hazardous waste packaging and disposal protocols for contaminated materials and compliance with Department of Defense cybersecurity controls.
Remediation Services

POSTED

5 days ago

DEADLINE

in 3 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS