Replace HVAC units (7) at Mashpee Service Unit
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
The contract involves replacing seven existing HVAC units across three buildings at the Mashpee Service Unit, with work focused on the Admin, Medical, and Dental buildings, each measuring 2,400 square feet. Two outdated Trane rooftop units will be removed and replaced with new appropriately sized units on both the Admin and Medical buildings, while the Dental building will have its existing Bard vertical mounted units removed and replaced with new vertical mounted packaged units—two units in the Dental building and a single unit in the Admin building. All replacements are designed to meet the specific heating and cooling demands of each facility. The contract is titled Replace HVAC units (7) at Mashpee Service Unit, solicitation number 75H71526R00006, and is set aside exclusively for small businesses under the SBA Total Small Business Set-Aside provision. It falls under NAICS code 238220 for plumbing, heating, and air-conditioning contractors, with performance located in Mashpee, Massachusetts, and managed by the Nashville Area Indian Health Service under the Department of Health and Human Services. Proposals are due by August 12, 2026, and the solicitation was posted on July 13, 2026, with Andrew Rhoades listed as the primary point of contact.
General Info
Contract Value
$164,443Place of Performance
Mashpee, MA, 02649, USASet-Aside
Awardee
K2 CONTRACTING GROUP LLCAward Issued Date
Timeline
Organization & Contact Information
Full Description
- Replace Roof Top Units on Admin Building: Remove the two existing Trane package rooftop units from the 2,400 SF Admin Building. Install a new rooftop unit appropriately sized for the building’s cooling and heating needs.
- Replace Roof Top Units on Medical Building Remove the two existing Trane package rooftop units from the 2,400 SF Medical Building. Install a new rooftop unit appropriately sized for the building’s cooling and heating needs.
- Replace Package Vertical Mounted Unit on Admin Building: Remove the existing Bard package unit from the 2,400 SF Dental Building. Install a new vertical mounted packaged unit appropriately sized for the building’s cooling and heating needs.
- Replace Package Vertical Mounted Units on Dental Building: Remove the two existing Bard package units from the 2,400 SF Dental Building. Install a new vertical mounted packaged unit appropriately sized for the building’s cooling and heating needs.
Similar Contracts
Same NAICS industry code
Ready to Pursue This Opportunity?
Get AI-powered intelligence on this solicitation and the ones like it
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS