Reroute Power Supple at the Phoenix Rearing Facility
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
A licensed electrician is required to remove a hazardous two-conduit setup and reroute the 240-volt three-phase power and control wiring overhead to a mixing blender at the Phoenix Rearing Facility, located at 3645 E. Chipman RD, Phoenix AZ 85040. The power supply originates from a breaker panel in an adjacent room, necessitating new rigid conduit installation through a wall, while the control wire panel is within ten feet of the blender. All conduit connections must be sealed to prevent electrical arcing due to flammable dust from wheat and soy, despite the presence of a dust collection system. The work must comply with safety standards for hazardous environments and prioritize durable, sealed rigid conduit. The solicitation is exclusively for small businesses under a total small business set-aside, with a contract value under $25,000 and a NAICS code of 238210. A mandatory site visit is scheduled for July 23, 2026, at 10:00 AM, led by Marvin Draper. All inquiries must be submitted via email to erick.plamann@usda.gov no later than 12:00 PM Central Time on July 29, 2026, and all offers must be sent to the same email by 12:00 PM Central Time on August 12, 2026, with a final response deadline of August 14, 2026, at 5:00 PM.
General Info
Agency
NAICS
Place of Performance
Phoenix, AZ, 85040, USASet-Aside
Documents
(4)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
Response Deadline
Organization & Contact Information
Full Description
Reroute Power Supply
POC: Erick Plamann, Contract Specialist, erick.plamann@usda.gov
a licensed electrician remove the 2 conduit tripping hazard and reroute the supply power and control wires overhead to the mixing blender. The breaker panel for the 240-volt 3 phase supply power is located in the next room where the electrician will
have to run new conduit through a wall to the mixing blender. The control wire panel is located within 10 feet from the mixing blender. We prefer that the electrician uses rigid conduit and seals all connections to prevent electrical arching. We do
have fine dust particles from wheat and soy which can become highly flammable. The kitchen possesses a dust collecting system which gathers most of the dust particles.
NAICS Code: 238210
This is being solicited 100% Small Business
Magnitude: Under $25,000
Site Visit
Date: 23 July 2026
Time: 10:00 AM
Location: 3645 E. Chipman RD, Phoenix AZ 85040
POC: Marvin Draper
POC Email: marvin.draper@usda.gov
All question must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 7/29/0226.
All offers must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 8/12/0226.