Research Triangle Park Forestry Sciences Laboratory HVAC Repair
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
Solicitation 1240BE27Q0025 is a Request for Quotation (RFQ) issued by the USDA Southern Research Station for HVAC repairs at the Research Triangle Park Forestry Sciences Laboratory in Durham, North Carolina. The project is a Total Small Business Set-Aside under NAICS code 238220. The scope of work involves diagnosing and repairing a Mitsubishi VRF system at the Forest Science and Assessment Center, which is currently failing to maintain set points due to a suspected refrigerant leak. Additionally, the contractor must block and seal redundant outside air vents on Fan Coil Units at the Forestry Science Laboratory to prevent unconditioned air from entering the building and causing freeze-stat trips. The contractor must perform a comprehensive electronic leak search, provide a detailed repair quote for labor and materials, and calibrate the system to manufacturer specifications upon completion. Performance must begin within 30 calendar days and be completed within 60 calendar days of authorization. Award will be based on the most technically advantageous solution, evaluating the technical approach, past performance over the last three years, and fair and reasonable pricing. Proposals must be submitted via email to Jared Machgan by December 1, 2026, and must include a technical proposal, past performance record, and a completed price schedule.
General Info
Place of Performance
Set-Aside
Documents
2Read all 2 documents
Due in 5 daysEvery page of every file, in your free workspace.
Read the documentsAI Contract Breakdown
Uniform Contract FormatSign up to view the full breakdown with detailed analysis of each section.
View Full BreakdownPotential competitors
63 companies- CONTROL SYSTEMS, INC. 4%
- CAS FSE JV II LLC 3%
- RIOMAR GROUP VENTURES, INC. 3%
- Other companies 90%
Review awarded contracts behind each match to see who has relevant experience.
Explore potential competitorsSolicitation requirements
72 mandatory88 requirements in 10 areas
- Compliance31 · 28 must024
Employee Service Classification
- Cost & Pricing14 · 14 must073
Repair Quote Requirements
- Submission18 · 9 must001
Offer Submission Method
- 85 more requirements, each with its source quote
Read every requirement with its source and proposal context.
Read all 88 requirementsEverything you need to bid on this one
Open the full contract in your free workspace.
- 2 solicitation documentsRead every page
- AI contract breakdown13 sections, Uniform Contract Format
- Buyer contactEmail
Ask CLEATUS
I've read this contract. Ask me anything.
Timeline
Combined Synopsis
Submission deadline
Organization & Contact Information
Full Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12. This announcement constitutes the only solicitation. Quotations are being requested and a separate written solicitation will not be issued.
Solicitation number 1240B27Q0025 is issued as a Request for Quotation (RFQ) for Research Triangle Park Forestry Sciences Laboratory HVAC Repair
This acquisition is set-aside for small business concerns. The applicable North American Industry Classification Standard Code is 238220 The small business size standard is $19 M This acquisition is a Total Small Business Set-Aside. All responsible sources may submit a quotation which will be considered by the agency.
The primary HVAC system (ACCU-1/VRV 2-7) for the Forest Science and Assessment Center (FSAC) is a Mitsubishi VRF system (BHM06227, Model PURY-P120TLMU-A, Serial 79W00897, 10 tons, R-410A) with 6 interior units. The system does not maintain condition set points and an initial evaluation during a preventative maintenance service call diagnosed with a potentially significant refrigerant leak.
The Forestry Science Laboratory (FSL) building’s Fan Coil Units (FCUs) are redundant in the current HVAC system. The outside air vents are no longer needed and are introducing unconditioned air into the building. During cold weather, this can lead to the coils potentially freezing and have led to the freeze-stats tripping, resulting in nuisance shutdowns.
Similar Contracts
Same NAICS industry code
More opportunities from Department Of Agriculture → Southern Research Station
Same awarding agency
Get AI-powered intelligence on this solicitation and the ones like it
Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.
Join 900+ contractors already using CLEATUS
