Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, July 22 at 2:00 PM EDT

Register Free →

RFQ - RECTANGULAR SHADE AWNINGS

Active
BPM013269State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

California → San Diego CountyView Agency

NAICS

238190 - Other Foundation, Structure, and Building Exterior ContractorsView NAICS

Place of Performance

San Diego, CA, USA

Set-Aside

NONE

Documents

(1)

RFQ 13269 Rectangular Shade Awnings and Installation

PDFrfq

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → San Diego County
Contacts1 person available
OfficeN/A
Organization / Agency
California → San Diego County
View Agency Profile
Office AddressN/A
Contacts
Joshua BlandinoProcurement Specialist

Similar Contracts

NAICS: 238190
New
SLED
MI 2646 HCTP CCC Roof Caulking and FEB Joint CaulkingThe contract pertains to caulking and sealing work at the Hill Canyon Treatment Plant located at 9600 Santa Rosa Road in Camarillo, California, specifically targeting the flow equalization basin and the concrete contact channel roof. The scope includes removal of all existing caulking from the FEB concrete joints and the removal of any loose or failing expansion joint material from the roof joints, followed by proper substrate preparation in accordance with the caulking manufacturer’s specifications or as directed by the Engineer. The work further requires installation of backer rod and bond breaker tape, application of primer and the specified caulking sealant, proper disposal of all construction waste in compliance with legal regulations, and thorough site cleanup upon completion. All tasks must be executed to ensure long-term waterproofing and structural integrity of the concrete joints. The solicitation, titled MI 2646 HCTP CCC Roof Caulking and FEB Joint Caulking with reference number 2025/2026-34, was posted on July 17, 2026, with a response deadline of August 12, 2026. It is issued by the Public Works agency under the State of California, with the office located in Thousand Oaks. The primary point of contact is Paul Weinstein, Associate Analyst, reachable at 805-449-2459 or pweinstein@toaks.gov, with Andrew Becker, Purchasing Supervisor, serving as the secondary contact at 805-449-2203 or abecker@toaks.gov. The project is solicited under a SLED-type agency designation, and interested parties must submit responses through the online procurement portal prior to the stated deadline.
Public Works

POSTED

about 12 hours ago

DEADLINE

in 26 days
View Details
NAICS: 238190
New
International
M-10 Partial Exterior Envelope ReplacementThe contract pertains to the exterior envelope and main entrance renewal of Building M-10 at the National Research Council Canada’s campus located at 1200 Montreal Road, Ottawa, Ontario, K1A 0R6. This procurement, identified by solicitation number 26-58015 under NAICS Code 238190, is exclusively open to Canadian suppliers due to the Policy on Reciprocal Procurement, and submissions from non-trading partners will be rejected. Bidders are required to attend one of two mandatory site visits on June 16 or 17, 2026, at the main entrance of Building M-10. Proposals must be submitted by July 22, 2026, and all work must be completed by March 31, 2027, with a performance period of 36 weeks from notification of award. The scope includes demolition, concrete restoration, metal fabrications, thermal and moisture protection systems, aluminum doors and glazing, gypsum board assemblies, and granular backfill, all executed in accordance with specified construction sections and technical requirements. Contractors must retain a qualified geotechnical engineer for investigations and testing, and all materials must be delivered in original factory packaging, labeled with manufacturer details, and stored off the ground in dry, clean, well-ventilated areas per manufacturer instructions. Packaging waste must be removed and returned as per the Construction Waste Management Plan. The contractor is obligated to comply with stringent security protocols, including valid Security Clearance for all personnel as outlined in SC01, and must maintain site security during alterations. Performance and payment bonds in prescribed government formats, issued by federally, provincially, or territorially licensed sureties, are mandatory. Insurance coverage must be obtained from insurers licensed to operate in Canada, and compliance with both Ontario and federal occupational health and safety regulations is required. All quality control testing must be conducted by independent agencies paid for by the contractor, with reports submitted digitally and including project identification, agency details, and dates. Final aesthetic standards demand defect-free surfaces, with walls and ceilings inspected under specified viewing conditions and lighting, and all products must be new, undamaged, and of the highest quality. The contractor must maintain complete and accurate financial records in machine-readable formats such as Excel, available for audit at Canada’s request during normal business hours. Cost breakdowns must be submitted within 72 hours of award and serve as the basis for all claims. A master Gantt
National Research Council of Canada

POSTED

about 22 hours ago

DEADLINE

in 5 days
View Details