Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

Rooftop Structural Assessment and Reinforcement

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The contract pertains to a comprehensive evaluation of the structural integrity of a new rooftop location in Irvine, California, with the primary objective of determining its capacity to safely support proposed equipment weight and withstand wind load conditions. This assessment will involve detailed engineering analysis to identify any deficiencies in the current structural framework and to recommend necessary reinforcements that ensure long-term stability and compliance with safety standards. The work is classified under NAICS code 238910, indicating it falls within specialized construction services focused on structural reinforcement and modification. The subcontract is issued by the City of Irvine and seeks qualified contractors to perform the structural assessment and implement any required upgrades. The place of performance is specifically designated as Irvine, and the solicitation was posted on June 9, 2026. Although no set-aside provisions or organizational type details are specified, the project emphasizes technical precision and adherence to structural engineering best practices. All findings and proposed modifications must ensure the rooftop can reliably accommodate the intended mechanical or electronic equipment under extreme environmental conditions, particularly high wind events common to the region.

General Info

Structural assessment and reinforcement of Irvine rooftop to support equipment and withstand wind loads.

Agency

California → City of Irvine

Place of Performance

Irvine, CA

Set-Aside

NONE

Documents

This scope was carved out of 00954839-PCPM.

The full solicitation package (1 document), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Minor Modification to a Wireless Facility (File No. 00954839-PCPM)

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

subcontract

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → City of Irvine
ContactsNo contacts available
OfficeN/A
Organization / Agency
California → City of Irvine
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Evaluation of structural integrity for the new rooftop location; potential reinforcement to support equipment weight and wind load.

Similar Contracts

Same NAICS industry code

NAICS: 238910
New
SLED
ITB-26-22 - City Center Sport Complex Ballfields Restoration
Solicitation # ITB-26-22-CW
The City of Port Orange has issued solicitation ITB-26-22-CW for the restoration and reconstruction of the City Center Sport Complex Ballfields. The project involves approximately 8 acres of developed parkland situated on a former municipal landfill. The scope of work includes the excavation and removal of the upper three feet of soil, the identification and lawful disposal of buried waste, the installation of a reinforced geotextile membrane, and the subsequent replacement of fill and topsoil. Additionally, the contractor will rebuild the ballfields, parking lot, and associated site improvements. The contract term is 395 days, and the City intends to award the project to the lowest responsive and responsible bidder based solely on the Base Bid. Eligible bidders must be certified General Contractors licensed in the state of Florida. The submission process requires a comprehensive package including a bid bond equal to 5 percent of the total bid, a bonding capacity letter for 100 percent of the bid amount, and various compliance affidavits covering E-Verify, non-collusion, and public entity crimes. Bidders must also provide professional references and a statement of qualifications. Technical specifications mandate that off-site manufactured materials be ISO 9000 certified and that all work adhere to OSHA and Florida Department of Commerce safety regulations. Final acceptance of the project is contingent upon a certified financial inspection by the city and written approval from the Project Architect.
Engineering

POSTED

about 15 hours ago

DEADLINE

in 12 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS