Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on June 4, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Sources Sought Market Survey for Unidirectional Flushing

Closed
UNIDIRECTION-FLUSH2021Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237110
New
Morgans Branch Force Main and Pump Station Improvements
Solicitation # SRP-W-134-0290
The Morgans Branch Force Main and Pump Station Improvements project, solicitation number SRP-W-134-0290, is a construction contract for the City of Belmont, North Carolina, with an estimated value of 16,690,000 dollars. The scope of work involves the construction of 16,435 linear feet of new 20-inch ductile iron force main and comprehensive upgrades to the Morgans Branch Pumping Station. Key infrastructure improvements include the installation of a new wet well, valve vault, and associated appurtenances, as well as the demolition of existing pumps and piping. The contractor is responsible for delivering a fully operational facility, including the installation of pumps, a generator, odor control equipment, new gravity sewers, and manholes, while managing by-pass pumping, testing, and commissioning. The contract will be awarded to the responsible bidder submitting the lowest responsive bid, with a strong emphasis on MWBE compliance through the submission of Good Faith Efforts and Table A documentation. Bids are due by November 12, 2026, and must be submitted using the EJCDC C-410 Bid Form. The project is governed by EJCDC standard general and supplementary conditions, requiring performance and payment bonds and proof of insurance. Technical standards include AWWA Specification C-600 for pipelines, NEMA MG1 for motors, and AWS D1.2 for aluminum welding. Project administration is managed by the City of Belmont with Willis Engineers serving as the project engineer. Payment is processed via Applications for Payment, with terms set at 30 days after presentation to the owner.
Don Moorhead Construction, Inc.

POSTED

about 4 hours ago

DEADLINE

in 20 days

General Info

NAICS

237110 - Water and Sewer Line and Related Structures Construction

Place of Performance

Aberdeen Proving Ground, MD, 21005, USA

Set-Aside

NONE

Documents

1

SOURCES+SOUGHT+NOTICE-Unidirectional+Flushing.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseClosed
Posted

Sources Sought

Notice updated

NAICS code changed from 924110 to 237110.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W6QK Acc-Apg Director
Contacts1 person available
OfficeABERDEEN PROVING GROU, MD, 21005-3013, USA
Office AddressABERDEEN PROVING GROU, MD, 21005-3013, USA

Full Description

Show more
Unidirectional Flushing will consist of locating, inspecting, assessing, and operating distribution sytem valves and hydrants, recording water flowed and creating a deliverable GIS format compatible with Aberdeen Proving Grounds' existing GIS/Database system. Execute minor repairs to valves and/or hydrants according to Government directions. Fire hydrants shall be inspected for appearance, accessibility, leakage, and functionality in accordance with AWWA M-17 manual, NFPA 291 and the Installation Safety Office requirements. The main line valives shall be inspected for accessibility and functionality in accordance with AWWA M-44 manual. Backflow Prevention Devices (BFPD) shall be inspected for evidence of dripping and leaking to protect the drinking water supply. The BFPDs shall be inspected and tested annuallly as well as certified to ensure the device is operational and entered into an authorized Cross Connection Control Management Program. The contractor will be required to perform annual maintenance and repairs on the BFPDs. Devices that have failed shall be repaired and retested at date and time of original scheduled testing event. A list of devices will be given at the time of award.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS