Steam Piping Insulation

Open
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

NAICS

238310 - Drywall and Insulation Contractors

Place of Performance

West Haven, ME, 06516

Set-Aside

SDVOSBC

Documents

This scope was carved out of 36C24127Q0058.

The full solicitation package (1 document), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

J041--Building 2 Steam Station Replacement

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Performs removal and installation of thermal insulation on steam lines for prime contractors on VA Connecticut Healthcare System facility projects. Removes existing insulation to facilitate mechanical work and installs new insulation on all disturbed or newly installed piping per VA specification requirements for steam service. Delivers insulated steam piping.

Similar Contracts

Same NAICS industry code

More opportunities from Department Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)

Same awarding agency

NAICS: 238220
New
Federal
J041--Building 2 Steam Station Replacement
Solicitation # 36C24127Q0058
Solicitation 36C24127Q0058 is a combined synopsis and request for quotation for a firm-fixed-price contract to replace the steam pressure reducing stations in Building 2 at the West Haven VA Medical Center. This requirement is a Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside under NAICS 238220. The project involves a complete turnkey installation to replace non-functional 2-inch and 2.5-inch steam regulators, including the removal of leaking cross tees and the installation of new Schedule 80 piping, safety relief valves, and a pressure gauge system designed for visibility from outside the confined space. The work must be performed during two consecutive boiler plant steam outages scheduled between March 1, 2027, and May 31, 2027, with a total period of performance of 180 days from the notice to proceed. Offerors must be registered in the System for Award Management (SAM) and VISTA to be eligible for award. Evaluation will be based on best value, considering price, technical capability, and past performance, with a requirement for at least one to three relevant references. Technical qualifications include a minimum of three years of experience in commercial/industrial steam boiler installation and mandatory OSHA 10 and 30 certifications. Due to the nature of the work, contractors must adhere to strict safety protocols, including Lock-Out-Tag-Out Policy 138-075 and Confined Space Entry SOP SO-010, and must manage asbestos abatement for specific flanged connections. Quotes must be submitted electronically to Tnauri Woodbridge by December 3, 2026, at 10:00 AM EST.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

about 19 hours ago

DEADLINE

in 22 days
View Details
NAICS: 811310
New
Federal
J061--Eaton Powerware System Replacement
Solicitation # 36C24127Q0030
The Department of Veterans Affairs is soliciting quotations for the replacement and ongoing maintenance of an end-of-life uninterruptible power supply system at the Manchester VA Medical Center in New Hampshire. This procurement is 100 percent set aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 811310. The scope of work requires the installation of an Eaton 93E UPS 20-60kVA (specifically 60 kVA; 208/208 V; single feed) and a 40-60kVA 4-String Extended Battery Cabinet, or an equivalent. The contract structure includes a base year running from January 4, 2027, through January 3, 2028, with four subsequent 12-month option years. The selected contractor must be authorized to work on Eaton products and possess the necessary proprietary software. Key performance requirements include a four-hour response time for emergency call-backs, completion of repairs within 24 hours of identification, and the provision of annual staff training. All work must comply with OSHA, EPA, NFPA, and VA codes, and personnel must meet strict vetting, credentialing, and licensing requirements. The government will evaluate offers based on technical quality, past performance, and total evaluated price. A recommended site visit is scheduled for November 16, 2026, at 9:00 AM EST, requiring advance notification by November 12, 2026. Written questions are due by November 19, 2026, and final quotations must be submitted via email to the Contract Specialist by November 26, 2026, at 5:00 PM EST. Submissions must include a signed Certificate of Compliance regarding limitations on subcontracting, certifying that no more than 50 percent of the work, excluding materials, will be performed by non-similarly situated entities.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

about 19 hours ago

DEADLINE

in 16 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS