This Solicitation opportunity from Government of Canada was posted on July 24, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
Technical advisory and project management services - Hypobaric Chamber (ACAN)
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
The Department of National Defence is seeking technical advisory and project management services for the complete refurbishment and recommissioning of the hypobaric chamber at the Canadian Forces School of Survival and Aeromedical Training located at 17 Wing Winnipeg. The project involves remediation of critical safety hazards including vacuum and oxygen leaks, electrical risks, and non-compliant components, alongside hazardous material abatement for substances such as lead paint, asbestos, and R-22 refrigerant under negative-pressure containment. The contractor will redesign the oxygen and CADO distribution system using a MIL-STD-1330E-compliant 3-way valve, develop updated Canadian Forces Technical Orders, deliver comprehensive training to facility operators and maintenance personnel, and coordinate all commissioning activities including gas purity sampling, pressure integrity testing, and functional verification under DND Technical Authority oversight. All work is strictly on-site at CFB Winnipeg and requires personnel to hold Reliability Status security clearance. This procurement is conducted as a sole-source award under subsection 6(d) of the Government Contracts Regulations, justified on the basis that only one supplier—Shanfe Research and Consulting Ltd.—possesses the unique technical expertise required to perform the task. The contract is valued at an estimated $360,000 CAD, excluding taxes, with no options or line-item pricing breakdowns specified. Evaluation is based on eight mandatory criteria, each treated as a pass/fail requirement, including demonstrated experience with hypobaric and oxygen systems, compliance with ASME PVHO-1, NFPA 99B, MIL-STD-1330E, CSA Z275.1, CSA Z462, and applicable CFTOs, as well as project management, commissioning, and training capabilities. Submission of a Statement of Capabilities is required by August 10, 2026, via email to the Contracting Authority, and no formal competitive process or pricing evaluation will occur unless a competing offer is received. Intellectual property developed under the contract remains the sole property of the contractor.
General Info
Agency
NAICS
Place of Performance
Canada, CANSet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
More opportunities from Government of Canada → Department of National Defence
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS
