Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

Thermal and Moisture Protection

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This subcontract for Thermal and Moisture Protection involves providing specialized waterproofing and joint sealant services for Bowling Green State University utility and tunnel rehabilitation projects. The selected contractor will work under prime contractors to install bituminous dampproofing, cold fluid-applied waterproofing, firestopping, and joint sealants in accordance with Section 07 84 00 to ensure all structural joints and surfaces are properly sealed. The project is managed by Bowling Green State University Campus Construction under NAICS code 238390. Interested parties must submit their responses by the deadline of October 22, 2026, following the posting date of October 16, 2026.

General Info

Waterproofing and joint sealant subcontract for Bowling Green State University, due October 22, 2026.

Agency

Bowling Green State University - Campus Construction

Place of Performance

USA

Set-Aside

NONE

Documents

This scope was carved out of 9158.

The full solicitation package (11 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

9158 Utility and Tunnel Rehabilitation - Shatzel to Moseley

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyBowling Green State University - Campus Construction
ContactsNo contacts available
OfficeN/A
Organization / Agency
Bowling Green State University - Campus Construction
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Applies waterproofing and joint sealants for prime contractors on Bowling Green State University utility and tunnel rehabilitation projects. Installs cold fluid-applied waterproofing, bituminous dampproofing, joint sealants, and firestopping per Section 07 84 00. Delivers sealed and waterproofed structural joints and surfaces.

Similar Contracts

Same NAICS industry code

NAICS: 238390
New
Federal
J065--RFQ - INSTALL LEAD BASED LINERS - 544 Columbia SC, 29209
Solicitation # 36C24727Q0036_0001
Solicitation 36C24727Q0036 is a request for a one-time service to supply and install lead-based liners in the Dental Clinic at the WJB Dorn VA Medical Center in Columbia, South Carolina. This procurement is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The contractor is responsible for furnishing all labor, travel, equipment, and materials to install 1/16 inch lead-lined boards on a wall area of approximately 101 to 252 square feet, reaching a maximum height of 7 feet. The scope of work requires a Level 4 drywall finish per ASTM C840 and adherence to ASTM C1396/C1396M specifications for the liners. While the contractor must ensure seams and penetrations are shielded and follow OSHA guidelines, the VA is responsible for demolition, ICRA requirements, painting, and final radiation shielding testing. The period of performance shall not exceed three months from the date of award, with work tentatively scheduled from 6:00 p.m. to midnight, Sunday through Friday, excluding federal holidays. Award will be based on the Lowest Price Technically Acceptable (LPTA) basis, evaluating technical capability and total evaluated price. Offerors must provide a detailed technical approach, proof of OSHA and EPA compliance, and necessary licenses for handling lead-based materials. Invoicing is to be submitted electronically via the Tungsten Network after completion and inspection approval. Contractor personnel are required to check in and out at the Engineering Control Center and must maintain a secure worksite, removing all debris daily.
247-NETWORK Contract Office 7 (36C247)

POSTED

4 days ago

DEADLINE

in 4 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS