Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on March 14, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Thyroid Uptake System, Poplar Bluff, MO VAMC

Closed
36C25525Q0265Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Poplar Bluff, MO, 63901, USA

Set-Aside

NONE

Documents

1

Sources Sought Notice 36C25525Q0265 - Thyroid Uptake System

PDF, High priority: read this firstsources-sought
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Contacts1 person available
OfficeLEAVENWORTH, KS, 66048, USA
Office AddressLEAVENWORTH, KS, 66048, USA

Full Description

Show more
Statement of Requirement Thyroid Uptake Unit John J. Pershing VA Medical Center GENERAL INFORMATION The Nuclear Medicine service at John J. Pershing VA Medical Center (VAMC) in Poplar Bluff, MO will better serve its Veterans by acquiring this Thyroid Uptake System with Well Counting System with 2 Inch Well Shielding, a multi-purpose spectrum analysis instrument designed for diverse nuclear medicine applications. The system performs Uptake studies, wipe tests, and other user-defined tasks that are accomplished with speed and precision using this fully integrated computer-controlled instrument and its comprehensive selection of application software. Engineered for mobility, durability and operational efficiency, the unit handles clinical tests, safety compliance tasks, and system administration procedures quickly and accurately. Built-in menus follow conventionally established nuclear medicine procedures, providing step-by-step guidance throughout defined procedures. The system automatically performs calculations, stores patient information and test results, and outputs clear, concise reports. User-defined uptake protocols can be initiated. SCOPE Delivery of the Thyroid Uptake system will allow a bioassay program for quick and efficient measurement of the staff thyroid burden for radiopharmaceuticals, I-123, I-125 and I-131. Measurement results can be reported in cpm, dpm, uCi, or Bq. Action levels may be set by the user for each isotope. System reporting facilitates single bioassay report, summary of multiple bioassays on an individual staff member, and summary report on multiple staff members. Reports are easily printed or saved as PDF files. The Thyroid Uptake program supports multiple time-stamped uptake measurements, auto decay correction, user-defined uptake protocols, on-screen spectrum acquisition and analysis. The system provides reports that include normal ranges and allow notes/comments entered by the facility physician and technologists. The wipe test application automatically calculates net contamination levels and reports results in dpm, uCi and Bq. The program allows compliance with regulations for counting and reporting results of wipes taken for contamination surveys. The system allows user to define an unlimited number of - Area names and wipe - Locations entered within the areas for testing and documentation. Each area may be designated as - restricted, - unrestricted, - package or - sealed source. The user may specify count times, activity units, wide window, and individual isotopes and geometric efficiencies or simply utilize the wide range of factory default options. The program displays and stores the full spectrum with each wipe, automatically calculates net contamination levels and reports results in dpm, uCi or Bq. Wipes above the user defined trigger levels are easily identified. A detailed spectrum analysis may also be performed for any wipe to help identify isotopes causing contamination. Customized reports can be printed or saved in PDF format. The application specialist will provide training and guidance to ensure safe use of the equipment and the study and administration applications provided. The contractor will provide cybersecurity best practices information and training, when applicable. The contractor will provide application update to ensure information security in the current equipment and other factors that interconnects with the imaging system including the network, other current peripheral applications and other new tools and software that will be developed or installed to work with the current work station and imaging equipment hardware and software. REQUIREMENT/SALIENT CHARACTERISTICS/SPECIFICATIONS Common Nomenclature: MEDICAL SPECTROMETER HARDWARE Kind of material: ALL IN ONE Touch Screen Computer Electrical Data: Power: Low voltage transformer with hospital grade power cord and plug. Line Voltage: 120 VAC, 60 Hz, 2 AMP circuit breaker 230 VAC, 50 Hz, 1 AMP circuit breaker Dimensions, size, capacity: Minimum articulating arm with a minimum of 34 inch vertical range of travel with a minimum of 220 degree collimator rotation. Principles of operation: Multi-Channel Analyzer: Channels: 1024 Spectral Resolution: FWHM 8% Count Rate: (Maximum) 150,000 cps for Tc-99m Count Rate Stability: 99% Gross Count Rate Linearity: Within 5% up to 150,000 cps Pulse Height Linearity: Within 2% (independent of detector) Detector High Voltage Adjustment: Automatic adjustment for both probe and well; uses 10 ?Ci Cs-137 as the calibration source. Restrictive environmental conditions: User Set: Unlimited user defined Isotopes, setting ROI, half life, name, efficiency and range. Intended use: Factory Programmed: Au-198, Ba-133, Co-57, Co-58, Co-60, Cr-51, Cs-137, F-18, Fe-59, Ga-67, Ga-68, Gd-153, Ge-68/Ga-68, Hg-197, I-123, I-125, I-131, In-111, Ir-192, K-42, Lu-177, Na-22, Na-24, Pd-103, Ra-223, Se-75, Sr-85, Tc-99m, Tc-99m/Tl-201, Tl-201, Yb-169, Wide Window. Equipment with which the item is used, Job related tools: Probe: 2" x 2" Nal (Tl) integral line scintillation detector Other pertinent information that describes the item, material or service required: Uptake Stand: Dimensions: Arm down and retracted: 34" l x 26" w x 55" h (86.4 x 66 x 139.7 cm) Maximum Height: 60" (152.4 cm) Maximum Length: Arm Extended: 61" (154.9 cm) Collimated Shield: Flat field collimator meeting IAEA specifications Positioning: Distance bar and positioning light Casters: 4" Total locking Maximum weigh of 300 lbs. A maximum combined weight with Well Counter: 350 lbs. Power: Low voltage transformer with hospital grade power cord and plug. Line Voltage: 120 VAC, 60 Hz, 2 AMP circuit breaker 230 VAC, 50 Hz, 1 AMP circuit breaker OTHER UNIQUE REQUIREMENTS : Minimum of 2 inch well container Compatibility with Existing Equipment: TRM Compliance with VA Directives WINDOWS 10 compatible or Newest Windows Version compliance with VHA standards. Must be DICOM compliance, Directives or IT Policies, Required. Coordination with On-going Construction Project (provide the project number): N/A Warranty: 1 year from date of receipt and verification of installation/operation. Two years part/labor warranty Training: Initial installation and launch training staff and service support Service and/or Maintenance: Preventive maintenance and training support, to include two Operating Manuals and two Service Manuals Safety/ISO/IT/BioMed/SPS & Other Departmental Compliance: Must meet Technical Reference Model (TRM) VA/BioMed Compliance. DELIVERY Contractor must deliver all components of the system as stated in this solicitation within 30 days of award notice. Standard FOB Destination to: John J. Pershing VA Medical Center, 1500 North Westwood Blvd, Poplar Bluff MO 63901. Government-Furnished Property, Material, Equipment, or Information (GFP, GFM, GFE, or GFI) N/A SECURITY N/A SPECIAL MATERIAL REQUIREMENT two Operator's Manuals and 2 Service Manuals PLACE OF PERFORMANCE The system will be installed, serviced, and updated at the facility, John J. Pershing VAMC, Poplar Bluff, MO, Nuclear Medicine Department. Servicing, training, and support of personnel will be per stipulations on the final contract.

More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)

Same awarding agency

NAICS: 541620
New
Federal
F108--657A4-21-800 - VPIH Services for Remove and Replace End of Life Heating, Ventilation and Air Conditioning Construction
Solicitation # 36C25527R0004
The Department of Veterans Affairs, Network Contracting Office 15, is seeking qualified Service-Disabled Veteran Owned Small Business (SDVOSB) Architecture and Engineering (A/E) firms to provide VA Professional Industrial Hygienist (VPIH) services. This project supports the removal and replacement of end-of-life HVAC systems in Building 1 at the John J. Pershing VA Medical Center in Poplar Bluff, Missouri. The scope of work involves providing all labor, materials, equipment, and supervision for the oversight of asbestos and lead abatement activities, including Phase Contrast Microscopy (PCM) air monitoring and analysis, compliance monitoring, inspections, and clearance testing. The project is divided into four phases ranging from 8 to 14 days each. Key deliverables include the submission of all routine and clearance air sample results to the Contracting Officer's Representative within 24 hours of collection and a final report for each location summarizing pre- and post-abatement activities. This procurement is conducted under the Brooks Act and requires the submission of SF 330 qualification packages. Evaluation criteria focus on the resumes of the Project Manager and Quality Control Manager, specialized experience in active healthcare facilities, the firm's capacity to accomplish the work, and past performance. The anticipated contract type is Firm Fixed Price, and the updated NAICS code for this effort is 541620 for Environmental Consulting. Awarded contractors must comply with E-Verify and limitations on subcontracting, ensuring no more than 50 percent of the government-paid amount is paid to non-SDVOSB firms.
Environmental Consulting Services

POSTED

about 24 hours ago

DEADLINE

in 5 days
View Details
NAICS: 811210
New
Federal
J061--Uninterruptible Power Supply St. Louis VA Medical Center
Solicitation # 36C25526Q0678
The Department of Veterans Affairs, Network Contracting Office 15, is soliciting quotes for a five-year Indefinite Delivery Indefinite Quantity (IDIQ) firm-fixed-price contract to provide preventive maintenance, emergency services, repairs, and battery replacements for Uninterruptible Power Supply (UPS) units and batteries. The services will be performed at the St. Louis VA Health Care System, specifically at the John Cochran and Jefferson Barracks VA Medical Centers. The contract has a guaranteed minimum of $43,000.00 and a total ceiling of $215,000.00, with a period of performance extending from late 2026 through 2031. While initially a small business set-aside, the solicitation was updated via Amendment 0003 to be unrestricted. Award will be based on the Lowest Price Technically Acceptable (LPTA) process, where quotes are rated as either technically acceptable or unacceptable based on their ability to meet the Performance Work Statement and specifications. Contractors must provide evidence of safety training in OSHA 1910 Subpart S and NFPA 70E, as well as manufacturer certifications for the equipment being serviced. All invoices must be submitted electronically through the Tungsten system. The final deadline for quote submission is October 29, 2026, at 7:00 AM CDT.
Electronic and Precision Equipment Repair and Maintenance

POSTED

about 24 hours ago

DEADLINE

in 1 day
View Details
NAICS: 561730
New
Federal
S208--Grounds Maintenance Services for the St. Louis VA Medical Center Jefferson Barracks
Solicitation # 36C25527Q0023
Solicitation 36C25527Q0023 is a request for quotations for grounds maintenance services at the 126.65-acre Jefferson Barracks campus of the St. Louis VA Medical Center. This five-year IDIQ contract, with a guaranteed minimum of 2,500 dollars and a maximum ceiling of 950,000 dollars, requires the contractor to provide all labor, equipment, and materials for routine maintenance, including mowing, trimming, edging, weed control, and seasonal cleanup. The scope also includes spring and fall fertilizer and pest treatments, as well as emergency landscaping services with a required four-hour response time. Performance is measured against a Quality Assurance Surveillance Plan with strict standards for grass height and debris removal. The procurement utilizes a tiered set-aside evaluation process, prioritizing Service-Disabled Veteran-Owned Small Businesses (Tier 1), followed by Veteran-Owned Small Businesses (Tier 2), and other small businesses (Tier 3), with further priority given to HUBZone, 8(a), and women-owned concerns. Award will be based on the best benefit to the government, evaluating experience, technical approach, and price. Technical evaluations focus on equipment availability and the proposed operational plan. Offerors must submit three separate files containing pricing and certifications, a record of up to five relevant contracts from the last five years, and a detailed technical submission. Personnel are required to have completed the OSHA 10-Hour Construction Safety Course, and the contract mandates compliance with various FAR clauses and safety regulations.
Landscaping Services

POSTED

about 24 hours ago

DEADLINE

in 9 days
View Details
NAICS: 236220
New
Federal
Z2DA--657-24-111JC Renovate Ambassador Suite & Main Lobby B1
Solicitation # 36C25526R0167
Solicitation 36C25526R0167 is a Firm Fixed Price construction project issued by the Department of Veterans Affairs, Network Contracting Office 15, for the renovation of the Ambassador Suite and Main Lobby in Building 1 at the John Cochran VA Medical Center in Saint Louis, Missouri. This project is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 236220, with an estimated value between 1 million and 5 million dollars. The scope of work includes improving ADA access, repairing skylight leaks, updating finishes, correcting HVAC and electrical deficiencies, and replacing the revolving door with sliding or swinging doors. The project must be completed within a performance period of 330 calendar days, though some technical documents specify a construction period of 218 days. Award will be based on the Lowest Price Technically Acceptable (LPTA) selection process. To be considered technically acceptable, offerors must demonstrate relevant experience with hospital construction projects of similar magnitude completed within the last five years and provide a qualified Site Superintendent and Safety Officer, both with at least five years of experience. Proposals must include a detailed construction safety plan for working in an active medical facility and a certification of compliance regarding subcontracting limitations, ensuring no more than 85 percent of the government payment is paid to non-SDVOSB or non-VOSB firms. Proposals are due by November 4, 2026, and must include a technical proposal, a price proposal via SF 1442, and a bid guarantee of at least 20 percent of the bid price, not to exceed 3 million dollars.
Commercial and Institutional Building Construction

POSTED

2 days ago

DEADLINE

in 7 days
View Details
NAICS: 236220
New
Federal
657-26-602 Create Observation Unit JC
Solicitation # 36C25526R0162
Solicitation 36C25526R0162 is a negotiated request for proposal issued by the Department of Veterans Affairs Network Contracting Office 15 for the construction of an Observation Unit at the Saint Louis VA Medical Center, John Cochran Division. This project, identified as 657-26-602JC, involves the conversion of three rooms into a 3-bed observation unit and the renovation of seven additional triage and reception rooms within the existing Emergency Department. The estimated construction magnitude is between 500,000 and 1,000,000 dollars, with a required period of performance of 550 calendar days from the issuance of the Notice to Proceed. The project is set aside specifically for Service Disabled Veteran Owned Small Businesses (SDVOSB). The contract will be awarded using the Lowest Price Technically Acceptable (LPTA) process, evaluating five technical factors including relevant past performance in 24-hour medical facilities, contractor and key staff experience, subcontractor qualifications, and a comprehensive safety plan. Following multiple amendments to incorporate revised bid documents, full drawing sets, and final responses to requests for information, the proposal due date has been extended to November 6, 2026, at 2:00 PM CST. Requirements include the submission of a technical proposal, a price proposal, and original bid bonds. Awardees must provide performance and payment bonds within 10 days of award and adhere to a one-year guarantee period for elevator services.
Commercial and Institutional Building Construction

POSTED

2 days ago

DEADLINE

in 9 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS