Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

Traffic Control & Safety Services

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This subcontract for Traffic Control and Safety Services supports prime contractors on construction projects within the County of Sacramento. The scope of work involves the implementation of traffic control systems, the installation of construction area signage, and the placement of portable radar speed feedback signs and temporary TL-3 crash cushions in accordance with Caltrans Standard Plans T15-T21. The opportunity is managed by the DGS: CAPSD - Construction agency for the state of California under NAICS code 561990. Interested parties must submit their responses by the deadline of September 24, 2026.

General Info

Traffic control and safety services subcontract for Sacramento County projects, due September 24, 2026.

Agency

California → DGS: CAPSD - ConstructionView Agency

NAICS

561990 - All Other Support ServicesView NAICS

Place of Performance

CA, USA

Set-Aside

NONE

Documents

This scope was carved out of 4703.

The full solicitation package (16 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Hazel Avenue at US 50 Interchange Improvement Project - Segment 1

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → DGS: CAPSD - Construction
ContactsNo contacts available
OfficeN/A
Organization / Agency
California → DGS: CAPSD - Construction
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Provides traffic management and safety equipment for prime contractors on County of Sacramento construction projects. Implements traffic control systems, installs construction area signs, and places temporary crash cushions (TL-3) and portable radar speed feedback signs per Caltrans Standard Plans T15-T21. Delivers managed traffic flow and installed safety signage/barriers.

Similar Contracts

Same NAICS industry code

More opportunities from California → DGS: CAPSD - Construction

Same awarding agency

NAICS: 238210
New
SLED
Main Jail – Hall of Justice – Refurbish Existing Pipe Chase Leak Detection System
Solicitation # 41010
The County of Sacramento is soliciting bids for contract 41010 to refurbish the non-functional Raychem Tracetek leak detection system for sanitary and pressure water lines at the Main Jail facility located at 651 I Street. The project involves replacing the leak detection panel in the basement and refurbishing water sensing cables, zone connectors, leader cables, and control modules, with final integration into the facility's building management system. The estimated construction cost is 148,590.00 dollars, and the contract will be awarded to the lowest responsive and responsible bidder. Eligible contractors must hold a C-7 Low Voltage Systems Contractor license and provide all work through technicians certified by the system manufacturer. The project has a completion timeline of 90 calendar days. Due to the secure nature of the correctional environment, the contractor must adhere to strict security protocols, including mandatory background checks for all personnel and constant escorts while onsite. Work on the second and third floors is restricted to a window between 12pm and 4pm. Safety requirements include the use of N95 or P-100 respirators in designated pipe chases and compliance with NETA ATS and NFPA 70 standards. The contractor is responsible for testing the continuity of existing jumper cables, with a provided allowance to replace up to ten failed conductors. Final acceptance of the work is contingent upon the submission of certified record drawings and specifications, as well as the provision of four hours of operational training for facility trades. Bids must be submitted electronically via the Sacramento County Electronic Bidding Portal by November 5, 2026, at 2:00 pm.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

1 day ago

DEADLINE

in about 2 months
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS