Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Solicitation opportunity from North Carolina was posted on March 21, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Type I Ambulance with CAAS Compliance and Advanced Features

Closed
121-121-02242025-State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 441110
New
SLED
FY27 CO 60s045 Full Size 4-Door SUV 4x4 Rebid
Solicitation # 27-494DOT-FINAD-B-54569
Solicitation 27-494DOT-FINAD-B-54569 is a rebid for the procurement of full-size 4-door 4x4 sport utility vehicles for the Illinois Department of Transportation. These vehicles are intended for transporting public officials and sensitive testing equipment, as well as towing message boards and flood pumps during emergency repair projects. The response deadline is November 4, 2026. To be considered responsive, bidders must provide vehicles meeting strict technical specifications, including a minimum 8-passenger seating capacity in a 2-3-3 configuration, a wheelbase of at least 120 inches, and an overall length of at least 210 inches. Powertrain requirements specify a V8 naturally aspirated or V6 turbocharged engine delivering at least 350 HP and 350 lb-ft of torque, with a requirement for Flexible Fuel or Hybrid Electric compatibility. Additionally, vehicles must have a minimum towing capacity of 8,000 lbs with a factory-installed Class IV hitch receiver and 4WD or AWD capabilities. The contract is governed by the State of Illinois Standard Terms and Conditions, requiring a minimum 12-month warranty on supplies. Vendors must submit descriptive manufacturer literature and completed specifications with their bids to avoid rejection. Payment is managed under the State Prompt Payment Act, and the contract may be funded partially or totally by federal funds. Awardees must comply with various state certifications, including the Illinois Department Human Rights Act, the Illinois Procurement Code's revolving door provisions, and cybersecurity directives from the U.S. Department of Homeland Security. The State reserves the right to inspect all units prior to acceptance to ensure they are fully operational and defect-free. Legal claims arising from the contract must be filed exclusively with the Illinois Court of Claims.
FINADMIN494 - Finance & Administration

POSTED

about 7 hours ago

DEADLINE

in 7 days

AI Contract Overview

Show more

This contract involves the procurement of a Type I ambulance built on a 2025 Ford F450 chassis, featuring a minimum 144-inch box length, with a gas engine or an equivalent functionally. The ambulance must comply with the CAAS GVS v 3.0 standards, ensuring adherence to the Commission on Accreditation of Ambulance Services Ground Vehicle Standards. It includes a regular cab equipped with essential amenities such as heat, air conditioning, power locks, power windows, and a radio, along with a backup camera system. The vehicle's wheelbase ranges from 158 to 175 inches, and the interior box must provide at least 70 inches of headroom. The exterior is equipped with extensive LED emergency lighting, including multiple red, white, and amber/yellow lights on the front, sides, and rear, complemented by interior LED lighting, ceiling-mounted light bars, dome lights, and cabinet-mounted LEDs. The ambulance features advanced operational and safety systems, including an integral generator of at least 5.5 kW, external hidden unlock switches, multiple compartment features with dri-deck material, and auto-eject shore power options. It is designed to operate with the chassis running, supporting electrical and HVAC systems, and includes oxygen and suction units, fire extinguishers, stainless steel countertops and grab rails, and various safety and communication devices such as sirens, USB ports, and backup warning systems. The interior is equipped with specialized storage, patient care features like a Stryker cot tower and floor track, and safety elements including seat harnesses, CPR seats, and protective head knocker guards. The contract, posted by Rowan-Cabarrus Community College in North Carolina, has a budget range of $200,000 to $300,000 and is scheduled for response submissions by April 17, 2025.

General Info

Place of Performance

NC, USA

Set-Aside

NONE

Documents

1

IFB #121-02242025 - Type I Ambulance

DOCX, High priority: read this firstifb
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyNorth Carolina → Rowan-Cabarrus Community College
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Type I ambulance with minimum 144” box length -2025 Ford F450 chassis with gas engine or functionally equivalent CAAS GVS v 3.0 unit compliant (Commission on Accreditation of Ambulance Services Ground Vehicle Standards) - 4 X 2 Drivetrain Regular cab with minimum heat, A/C, power locks, power windows, and radio - Back up camera system - Wheelbase minimum 158” to maximum 175” Interior box height (headroom) minimum 70” Exterior LED Emergency Lighting (minimum) • Two (2) Red Front Grill Lights • One (1) Red Left Front Fender Lights • One (1) Red Right Front Fender Lights • Six (6) Red and Two (2) White Front Box Scene Lights • Four (4) Red, Two (2) White and One (1) Amber/Yellow Rear Box Lights • Two (2) Red and Two (2) White Left Box Scene Lights • Two (2) Red and Two (2) White Right Box Scene Lights Interior Box Lights (minimum) • Four (4) LED Light Bars, Ceiling Mounted • Eight (8) LED Dome Lights, Ceiling Mounted • LED Lights Inside Cabinets Ambulance box must have the ability to operate with the chassis running (generator driven) -Integral generator (5.5 kw minimum) 110 volt to run ambulance box electrical and rear HVAC systems External hidden unlock switch - Minimum five-point harness in all box seats (four total) - Standard white/off white box with Rowan Cabarrus Community College Graphics (see example) Minimum 5 lb. mounted fire extinguisher - Dri-deck material in exterior compartments - Auto eject shore power 20/30 amp - Pigtail plug option - Oxygen compartment with M cylinder bracket/rollers Two D cylinder holders in oxygen compartment - Oxygen cylinder changing wrench dedicated to oxygen compartment - Connected oxygen regulator with hose in compartment for M cylinder Self-contained rear/box A/C unit with exhaust fan (capable of generator operation) - Rear/box heating - Backboard compartment with shelf - Door locks on all entry doors for cab and box Gas operated door holds for compartments - Siren speakers Whelen SA 315 -Siren Whelen C9 in console - Siren microphone - Siren Whelen C9 in console - Siren microphone - Single slot console switch panel in cab Siren mounted in console - Blank console slot with cover for future radio addition - USB / USB-C device connectors in cab and box - Armrests on seats in cab - 120 VAC connection in cab at console - Cab cupholders (2) Three box glove holder in cab - Backup warning system with speaker - Antitheft system - Stainless steel countertops in box - Stainless steel grab rails in box - Two duplex outlets in box - Safety netting in front corner area of box Mounted aluminum drug box, double locking, mounted in box - Minimum two oxygen outlets mounted in box with regulators (one on action wall, one near bench seating area -Thermostat control in box Mounted suction unit in action area of box - 120 VAC connection in box - Mounted door lock switches on action wall - Action area wall mounted large sharps container - Action wall lights and switches Single CPR seat with harness - Generator start/stop switch in box and in cab - Two seat positions on squad bench with harnesses - Squad bench cabinet - Handrail at head of squad bench Three box glove holder mounted on back way of box over squad bench - Mounted trash can with lid at head of squad bench or in step well - Two IV hangers on ceiling (one over stretcher, one over squad bench) Driver side stainless steel ceiling grab bar - Rear head knocker protections - Mounted clock - Stryker cot tower in box - Stryker floor track for power load Gen 2 Captain chair in box with integral child safety seat and harnesses - Cab running boards - D cylinder oxygen mount in box interior - Interior box cabinetry with Lexan doors

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS