Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from STATE, DEPARTMENT OF was posted on August 12, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

U.S. Embassy Antananarivo - Radio Repeater Services

Closed
PR15476939Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The U.S. Embassy in Antananarivo is soliciting proposals from vendors for the lease of telecommunications tower space and an associated technical room to support the installation of radio repeater equipment. The primary objective is to enhance network coverage and capacity at specific embassy-related sites in Ivandry, CMR Ambaranjana, and the Andranoro Antehiroka compound, with a performance period spanning from September 1, 2025, to August 30, 2026. The proposed installation requires both outdoor and indoor telecommunications equipment, including VHF antennas, GPS clocks, a Cisco gateway, microwave dish, Motorola base radios, UPS units, routers, and AC systems. Vendors are expected to provide details about rental terms, monthly costs, space availability on the tower (including exact height and orientation), and technical room conditions. The solution must meet strict power supply and backup requirements—stable dual 220V sources, independent circuit breakers, and reliable backup solutions. Structural certifications by professional engineers are required, along with a robust grounding and lightning protection system, periodic maintenance protocols, and comprehensive site security (including perimeter fencing, access controls, fire and flood sensors, and strict personnel access). Proposals should include clear costing structures—covering non-recurring and monthly costs, applicable taxes and fees, and cancellation charges—and must be submitted by August 28, 2025, to the designated embassy contact. Regular audits, ongoing compliance, and adherence to U.S. standards for telecommunications infrastructure will be mandated throughout the period of performance.

General Info

Lease telecom tower space and technical room for embassy radio equipment, September 2025–August 2026.

Agency

STATE, DEPARTMENT OF → ACQUISITIONS - AQM MOMENTUM

NAICS

517919 - All Other Telecommunications

Place of Performance

Antananarivo, MG-T, MDG

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencySTATE, DEPARTMENT OF → ACQUISITIONS - AQM MOMENTUM
Contacts1 person available
OfficeWASHINGTON, DC, 20520, USA
Organization / Agency
STATE, DEPARTMENT OF → ACQUISITIONS - AQM MOMENTUM
Office AddressWASHINGTON, DC, 20520, USA
Contacts
Princy Harimanjato

Full Description

Show more

The U.S. Embassy Antananarivo would like to invite vendors to provide price quote for the services of a telecommunications tower to support the installation of radio repeater equipment. The tower will be used to enhance our network coverage and capacity in Ivandry, the CMR Ambaranjana and the U.S. Embassy compound area Andranoro Antehiroka.



Period of performance (POP): 9/01/2025 – 8/30/2026.



Location Information:



In the area surrounding the GPS coordinates specified below.



GPS Coordinates:


Latitude: 18°51'56.7"S


Longitude: 47°31'49.3"E


https://maps.app.goo.gl/tp2PVMTS34JEVQgw9


Technical Requirements:


Outdoor Telecommunication equipment:


  • 02 Omnidirectional VHF Antenna 160Mhz – 174 MHz (minimum height requirement: 25 meters AGL)
  • 02 Omnidirectional antenna (ANT-LPWA-DB-O-N=) (minimum height requirement: 20 meters AGL)
  • 02 GPS clock
  • 01 Cisco Wireless Gateway for Lora WAN - 868MHz
  • 01 0.3m Point to Point Parabolic Microwave Dish Antenna


Indoor Telecommunication equipment to be installed in your technical room:


  • 01 18U indoor rack_Radio repeaters and Cisco Router inside
  • 01 3U indoor rack_Cisco Router inside
  • 02 2xMotorola GTR 8000 Base Radio (VHF/UHF)
  • 01 TRIPP.LITE SmartPro UPS_Input 230V~50/60Hz 6.9A_Output 230V~50/60Hz 6.5A_1500VA / 1350W_Number of phases: 01 With External Batteries: 1200W-Max Output Rating.
  • 01 Router with Internet Box
  • 01 AC Aircon
  • 01 AC Box


 In this regard, we kindly request information on the possibility of leasing space on your tower and within your technical room, including the following details:


  1. Rental Terms & Monthly Cost

Pricing for tower space and technical room


Duration and renewal conditions of the lease


Other conditions or constraints 



  1. Indoor and Outdoor Space Availability:

  • Exact location on the tower (height, orientation)
  • Available space inside the technical shelter or equipment room



  1. Power Requirements:

  • Independent circuit breaker for US Embassy installation
  • Availability of two stable 220V AC 50–60Hz power sources: one from the commercial power grid (JIRAMA) and the other from a diesel generator managed by an Automatic Transfer Switch (ATS)
  • Stable 220V / 50-60Hz including backup power solution.


Assurance of minimal power interruptions, with a specified power backup solution (e.g., UPS, commercial power availability (JIRAMA), local generators, rectifier/inverter).



  1. Structural Engineering

Certification by a licensed professional structural engineer or engineering firm with expertise in telecommunications tower design and analysis.



  1. Equipment room or Shelter

Restricted access, locked door with a lock or padlock, air conditioning in good working condition, walls and roof waterproof and sturdy, equipped with fire prevention equipment, smoke sensor, and flood sensor, correctly connected to the grounding network.


Equipment room or shelter well located on a site safe from the risk of flooding and fire.



  1. Earthing and protection

  • Proper grounding System: the site must have a low resistance grounding system, including a series of proper ground rods, plates, or a ground ring, which should be connected to the main electrical panel and telecom equipment.


  • Grounding resistance: the resistance should typically be less than 5 Ohms.


  • Lightning protection system: they are installed at the highest points of the telecom tower to intercept direct lightning strikes. They must be properly connected to the grounding system.


  • Down conductors: safely carry the lightning Strick from the air terminals to the grounding system, they should be short and direct to minimize the risk of damage.


  • Surge protection (SPDs): should be installed on the AC cables power lines and any other conductive paths entering the site to protect against induced voltages from lightning strikes.


  • Grounding bar: the tower and the equipment room or shelter must be equipped by some grounding bar that is properly connected to the grounding system.


  • Separation of power and telecom grounds: separate the grounding for power and telecom systems to avoid dangerous interaction between the two systems.


  • Periodic maintenance and inspection of the grounding system: it is required to ensure that the grounding system is in optimal condition. This includes checking the integrity of all connections and the resistance of the grounding electrodes.


  1. Compliance and Audits

Regular audits and inspections should be conducted to verify compliance with the Standards lightning and grounding system of the site.


  1. Security and Access Control:

  • Perimeter Security:

The tower site must be enclosed by a secure perimeter fence or barrier to prevent unauthorized access.


The fence height should be sufficient to deter trespassing and unauthorized entry.


Access gates must be equipped with locks or other security measures to control access to the site.



  • Access Control

Access to the tower site must be restricted to authorized personnel only.



  • Site Conditions

Site environment and accessibility (road access, terrain)


The site is in a secure area with appropriate protection against flooding and fire hazards.


Any constraints or limitations we should be aware of


Proposal Submission Instructions:


Costing information for twelve months in the following format:
     a.  Non-recurring costs (NRC), if any, in Ariary.
     b.  Monthly costs in Ariary.
     c.  Fees and or costs to cancel contract if the POP has not ended.


     d.  All the applicable taxes and or fees (e.g., VAT, & import migration fee.)



Accordingly, interested prospective offerors are invited to submit their quotation to contact@example.gov no later than August 28, 2025 at 12:00pm local time.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS