Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity was posted on May 2, 2012. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Upgrade of the Central Alarm Station (CAS)

Closed
APP-12-7134Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 561621
New
Centennial Fire Alarm & CO Detection Upgrade and Maintenance Services
Solicitation # centennial-fire-alarm-co-detection-upgrade-maintenance-services
Management & Training Corporation (MTC) is soliciting bids for a fixed-price, single lump sum contract to provide fire alarm and carbon monoxide (CO) detection upgrade and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The primary objective is to restore the central Simplex 4020 Fire Alarm Control Center Panel and connected systems across nine campus facilities to full operational status. The scope of work includes diagnosing and clearing system faults, upgrading motherboard firmware if necessary, and integrating CO detection into the men's and women's dormitories by installing intelligent multi-criteria detectors and sounder bases. All work must adhere to NFPA 101 (2024), NFPA 72 (2025), IFC (2024), and local building and fire codes. Bids are due by December 1, 2026, and must be submitted via email to Sandra Clore. A mandatory physical site visit is required prior to bid submission. Proposals must include a detailed cost breakout on company letterhead, proof of insurance, and warranty information. For bids equal to or exceeding $25,000, a bid bond guarantee of 20% of the base bid is required, and the awarded contractor must provide performance and payment bonds from an A-rated surety company. This project is subject to the Davis-Bacon Act and Construction Wage Rate Requirements, necessitating the submission of weekly certified payroll reports for payment processing. The solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certifications. Award decisions will be based on overall best value. Key deliverables include field service reports, signed NFPA 72 inspection and maintenance forms, and a structured digital asset report for integration into the facility's Computerized Maintenance Management System. Final payment is contingent upon a successful final inspection by the Buyer and the submission of a Notice of Final Completion, a Certificate of Release of Liens, and a Certificate of Payment of Debts and Claims.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 2 hours ago

DEADLINE

in about 1 month
NAICS: 561621
New
SLED
FY27 DC OIG Fire Protection Systems Maintenance
Solicitation # Doc852355
The Government of the District of Columbia Office of the Inspector General (OIG) is soliciting a qualified contractor under solicitation Doc852355 to provide comprehensive inspection, testing, maintenance, and repair services for fire protection infrastructure located on the 10th, 11th, and 12th floors. The scope of work specifically covers Victaulic Series 769N pre-action fire sprinkler systems and Janus clean agent fire extinguishing systems. A critical requirement of this contract is the provision of expert advisory and management services to transition the Janus systems from 3M Novec 1230 to an approved alternative suppression agent, with the changeover required to be completed before the end of 2025. The contractor must assign technicians specifically trained in the maintenance of Janus and I-769N systems and must adhere to NFPA 25 and NFPA 72 standards, as well as FM Datasheets and LPCB/EN guidelines. Key deliverables include signed electronic maintenance reports submitted to the OIG Facilities Manager within 24 hours of each service and the maintenance of signed PM checklists on-site. The contractor is also responsible for providing formal training to the Facilities Manager on system operations and emergency response. Administrative requirements include coordinating all schedules with the Facilities Manager, providing Material Safety Data Sheets for hazardous materials, and submitting invoices through the designated e-invoicing system.
Inspector General (OIG)

POSTED

2 days ago

DEADLINE

in 4 days
NAICS: 561621
New
SLED
Request for Information - OpenEye – CCTV Recording and Analytics
Solicitation # TCH2133148F1
Broward County has issued a Request for Information (RFI) under solicitation number TCH2133148F1 to determine if the OpenEye CCTV recording and analytics solution is available from multiple providers or if an alternative commodity can meet the County's specific needs. This process serves as a Notice of Intent to Designate Sole Source/Sole Brand and is not a request for pricing or a purchase commitment. The County is seeking a turnkey appliance featuring a hybrid architecture that integrates cloud management with on-premise video storage. The required solution must demonstrate advanced capabilities in architecture and system integration, including vendor-agnosticism and Genea access control integration. Key technical requirements include real-time person-of-interest identification, license plate recognition, and the ability to run simultaneous analytics across both legacy and new cameras. From a security and management standpoint, the system must utilize hardened Linux-based recorders, support Role-Based Access Control, and be proven secure via Nessus vulnerability scans with zero critical, high, or medium-level vulnerabilities. Additionally, all hardware must be backed by a full manufacturer's warranty and dedicated factory technical services. Interested vendors must submit responses via the electronic bidding system by November 16, 2026.
Broward County

POSTED

2 days ago

DEADLINE

in 22 days
NAICS: 561621
New
International
Video Management System Migration: Genetec
Solicitation # VA/CON/F26/40
The Victoria and Albert Museum is seeking a Genetec partner under solicitation VA/CON/F26/40 to supply, install, and implement a video storage solution. The project involves migrating all video surveillance cameras to a Genetec recording and storage platform across four locations: the V&A South Kensington site and three remote sites at Young V&A, Park Royal, and Dean Hill Park. The scope of work includes the provision of hardware such as Streamvault recording servers and Cloudlink devices, Genetec software licenses and support for a 12-month period, and professional services for configuration, installation, and integration. All deliverables must adhere to the museum's specific surveillance and retention standards, with a focus on ensuring seamless connectivity and management through the Genetec platform. The contract has an estimated total value of 443,000 GBP excluding VAT and is open to small and medium-sized enterprises. Award decisions will be based on the most advantageous tender, weighted 60 percent on quality and 40 percent on whole life cost. The procurement process follows a two-stage competitive flexible procedure, beginning with a pre-qualification questionnaire and followed by a formal tender for a shortlist of four to six suppliers, including mid-tender dialogue workshops. The estimated award decision date is December 3, 2026. The museum retains the right to vary the volume of services, make additional purchases, and extend the warranty period for an additional year.
Victoria and Albert Museum

POSTED

2 days ago

DEADLINE

N/A

General Info

Agency

N/A

NAICS

561621 - Security Systems Services (except Locksmiths)

Place of Performance

ROCKVILLE, MD, 20852, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts2 people available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts
Carol GreenwoodContract Specialist
Heriberto (Eddie) Colon JrSr. Contract Specialist

Full Description

Show more
RFI for Upgrade or Replacement of Central Alarm Station (CAS) APP-12-7134 PURPOSE The U.S. Nuclear Regulatory Commission (NRC) seeks information from industry for a future upgrade to the agency's Central Alarm Station (CAS). The information that NRC gathers from this RFI and related market research is for planning purposes only and may be used to assist the NRC in planning an acquisition strategy if an upgrade or replacement acquisition for NRC's CAS is deemed appropriate by NRC. BACKGROUND The NRC CAS has been operating for several years with minor and partial upgrades to the existing security equipment, systems, and components. Through time, newer equipment and technology has been added to legacy equipment creating incompatibility issues and decreasing the CAS' capabilities as an efficient user-friendly management and monitoring station. For example, the functions of access control, intrusion detection and video surveillance are all segregated forcing alarm station operators (ASOs) to monitor and control numerous workstations (areas) delaying assessment times and in some cases response times. The addition of a new building (3 White Flint Complex) provides an even greater need to upgrade the existing CAS in order to ensure integration of all security systems (i.e., access control, intrusion detection and video surveillance) from all buildings creating a flexible and more efficient management and monitoring system that will benefit the physical security program for the next several years. The NRC CAS' current security system configuration consists of the following: - Access Control System: Consists of a global server and several Regional servers operating GE Security's Facility Commander. - Intrusion Detection System: Consists of a Bosch 6600 receiver for local alarm monitoring. In addition, NRC utilizes Federal Protective Services for remote monitoring capabilities and requires certain rooms/areas to be UL 2050 certified. - Video Surveillance System: Consists of a partial analog camera system utilizing digital video recorders and a partial Internet Protocol camera based system utilizing network video recorders, none of which are integrated with the IDS or ACS. QUESTIONS 1. Provide detailed commercial literature or other readily available information about current commercial item solutions that NRC should consider in upgrading or replacing the aforementioned GE-based CAS. Include make, model, and commercial list price information (but not a proposal or quotation) for those products and indicate their compatibility with the aforementioned GE-based CAS components. Also, provide detailed information regarding extent to which these products comply with applicable Section 508 standards (see www.section508.gov). 2. Is your organization an authorized reseller/business partner for GE information technology (IT) security solutions? If so, then please indicate what those solutions are and provide commercial price list(s) or range of prices for those commercial item offerings, both for products and related services. Please also indicate if any products discussed in your response are available on any existing GSA contracts and if so, please provide the GSA contract numbers. 3. Please describe your organization's status with respect to NAICS 541519 (150 employee size standard) (e. g., other than small business, small business, woman-owned small business, HUBZone small business, service-disabled veteran-owned small business). 4. Describe your organization's experience over the past five years as a prime contractor providing and integrating a commercial item application of GE IT security solutions such as Facility Commander Wnx (FCWnx) in a Microsoft Windows environment for the integration of access control, intrusion detection and video surveillance into a central monitoring station. Also, please address your organization's experience with the GE FCWNx (Global Edition) multi-server system. Please indicate the scope (in detail), complexity, dollar value and period of performance for GE IT security solutions provided by your organization over the past 5 years as prime contractor, and provide the names, addresses, phone numbers and email addresses for customer points of contact for these projects that are familiar with your organization's work on those projects. 5. Describe your organization's experience within the past five years using the "C Language" interfaced with GE FCWnx, to include the complete configuration of an integrated access control, intrusion detection and video surveillance system. 6. Please describe your organization's experience centralizing and consolidating a central alarm station into a monitoring station with LED display panels and integrating other associated security equipment and systems, including but not limited to the integration of access control, intrusion detection and video surveillance. How would you show us what is the latest proven most up-to-date technology in access control, intrusion detection and video surveillance systems? 7. Describe your organization's experience providing operations and maintenance for GE IT security solutions (e.g., monitoring, trouble-shooting, emergency response, preventive maintenance). 8. Describe your organization's experience complying, or providing compliant solutions for federal agencies, for the Federal Information Security Management Act (FISMA) and NIST SP800-53 requirements for building security systems (e.g., security plans, contingency plans, risk management, patch management, and continuous monitoring). 9. Describe, in detail, your organization's experience with configuration change management and patch management on security systems and utilization of related performance metrics. Please describe your organization's experience addressing integration of power supply requirements with a new GE IT security solution. Please e-mail your responses to Carol Greenwood at Carol.Greenwood@nrc.gov by the stated response date deadline.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS