Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

Utility and Geotechnical Investigations for the Vasona Pump Station Upgrade Project

Forecast
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

California → Santa Clara Valley Water District

Place of Performance

Los Gatos, CA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseForecast
Posted

forecast

Prepare for this forecast

Research the agency, track this forecast, and prepare your capture plan before the solicitation opens.

Organization & Contact Information

Show more
AgencyCalifornia → Santa Clara Valley Water District
Contacts1 person available
OfficeN/A
Organization / Agency
California → Santa Clara Valley Water District
Office AddressN/A
Contacts
Christopher HallAssistant Environmental Planner II

Full Description

Show more
The proposed project includes small-scale utility and geotechnical investigations for information gathering purposes. The utility investigation would include fourteen (14) potholes at VPS. The confirmed locations of underground utilities would be incorporated into the capital improvement project’s design to minimize impacts to existing utilities prior to initiating construction. Typical pothole size would be 12-inches in diameter or 12-inch by 12-inch square. However, the actual size of the potholes would be determined based on the ability to avoid disruption and collateral damage, and level of confidence in locating the crown of the desired utility with available utility location records and field markings. The proposed excavations are small-scale and would be located within the existing facility’s paved areas and parking lots. The geotechnical investigation would include one (1) boring to determine the characteristics of the soil in the area. Boring soil samples would be obtained near the ground surface, at two and a half (2½) feet below ground surface (bgs), five (5) feet bgs, and every five (5) feet thereafter until the planned bottom of the hole is reached. The upper four (4) feet of each boring would be hand augured. The deeper borings would be drilled using a truck-mounted drill rig equipped with hollow-stem augers. If groundwater is encountered, then the drilling method would be switched to mud rotary. The contractor would be responsible for maintaining a log of the soils encountered, obtaining samples for visual examination, and classifying those soils using the Unified Soil Classification System (USCS), and laboratory testing.

Similar Contracts

Same NAICS industry code

Earlier notices in this NAICS code

Posted before this notice, open and closed

Prepare for this forecast

Research this forecast and prepare for the solicitation

Every page of the solicitation package shredded into a compliance breakdown