The Department of Veterans Affairs plans to solicit proposals for the purchase of a VPRO Max Low Temperature Sterilizer for the Kansas City VA Medical Center. This procurement is a one-time buy that includes delivery and installation within 90 days. The solicitation, expected to be issued around January 30, 2026, will be unrestricted and open to qualified vendors registered in the Small Business Administration and/or SAM databases under the applicable NAICS code 334510, which relates to Electromedical and Electrotherapeutic Apparatus Manufacturing. No set-asides are specified for this procurement. Interested contractors must download the solicitation and any amendments exclusively from the www.sam.gov website and are encouraged to register their interest there to receive updates. The solicitation number is 36C25526Q0168, and the response deadline is set for January 30, 2026, by 8:00 PM. The purchase falls under the PSC code 6530, which covers Hospital Furniture, Equipment, Utensils, and Supplies. The contracting office managing this acquisition is the 255-NETWORK Contract Office 15 located in Leavenworth, Kansas, with the point of contact being Jon Lutmer. This presolicitation notice serves only to inform interested parties of upcoming procurement opportunities and does not request bids or proposals at this stage.
General Info
Place of Performance
Kansas City, MO, 64128, USASet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
1. STATEMENT OF WORK
The contractor shall furnish all requisite services, labor, travel, transportation, materials, shipping,
parts, connections, and equipment for the provision and on-site installation of a minimum of three
vaporized hydrogen peroxide Low Temperature Sterilizers. These units are to be located at 4801
Linwood Blvd, Kansas City MO 64128. These low temperature sterilizers are essential for the Sterile
Processing Service (SPS) in reprocessing reusable medical devices (RMDs) employed in invasive
procedures. needed to support Sterile Processing Service (SPS) for reprocessing reuseable medical
devices (RMD) used in invasive procedures. Furthermore, these units are critical for supporting
medical procedures and surgeries and surgeries conducted within the Operating Room, as well as
in various ancillary clinics throughout the KCVA.
The contractor shall additionally furnish training to clinical personnel prior to the utilization of the
equipment. This training is to encompass all tours of duty for the sterile processing department and
necessitate annual retraining on all associated on all associated equipment. Moreover, the
contractor bears the responsibility for the removal and disposal of all debris and packaging
material resulting from the installation of the VPRO MaX2 Low Temp Sterilizers.
2. SPECIFICATIONS
• Three low temperature sterilizers shall have a minimum individual dimensions of Cabinet
(DD): 33 x 40-15/16 x 72” (838 x 1040 x 1829 mm) with Recessed/Cabinet (SD): 33 x
38-5/16 x 72” (838 x 973 x 1829 mm).
o Mounting single door, cabinet
o System installation requires no plumbing, ventilation or air
o supply – only a dedicated electrical connection is needed. A power cord is supplied
for this connection
o The facility space in which the vehicle can occupy is approx. 35’ x 110’.
• Vaporized hydrogen peroxide sterilization processes are particularly suited for sterilizing
heat- sensitive materials because temperatures within the load currently do not exceed
55ºC (131ºF) and sterilization occurs in a low-moisture environment. Heat tolerant devices
and materials can also be indicated for vaporized hydrogen peroxide sterilization processes.
FDA-cleared vaporized hydrogen peroxide sterilizers, either with or without plasma, are
currently available in the United States.
Per ANSI/AAMI ST58:2013 or subsequent, the sterilizer shall be installed and operated in
an area with a ventilation system capable of at least 10 air exchanges per hour.
VPRO MaX2 must support utility requirements:
o Current 16 AMP
o Minimum Circuit Breaker 20 AMPS
o Use NEMA L15-20R Plug
o Provide grouped or ganged circuit protection and disconnect for phase 3 power as
required by NEC and local codes.
o Individual power shutoffs near each machine for servicing.
Shall integrate with the CensiTrac Instrument Tracking System.
More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Same awarding agency
Earlier notices in this NAICS code
Posted before this notice, open and closed
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS