Warehouse Repairs, RAF Alconbury

Closed
FA557026R0002Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238160
New
OJCA Gym Roof Core Sampling
Solicitation # ojca-gym-roof-core-sampling
Education Training & Resources LLC is soliciting bids for roof core sampling services at the Oneonta Job Corps Academy in New York. The project involves conducting moisture assessments and core sampling on two specific areas: a flat roof installed in 1994 and a hip area installed in 2003. The primary objective is to determine moisture levels in the existing insulation to evaluate if the roof is suitable for a coating over the existing membrane. Key deliverables include the removal and temporary waterproof patching of roof sections, photo documentation of strata, and comprehensive laboratory analysis of the findings. The solicitation is open to various small business set-asides, including SBA certified, women-owned, HUBZone, and veteran-owned businesses. Bids are due by 12:00pm on September 16, 2026. Award decisions will be based on the best overall value rather than the lowest price, with evaluation factors including pricing, technical approach, and New York State licensing. Required submissions include a completed bid sheet, a detailed cost breakdown, a W-9, and a vendor acknowledgement form. The winning contractor must maintain an active Sam.gov registration and a Unique Entity ID. Compliance requirements are stringent, mandating adherence to OSHA regulations, the National Electrical Code, NFPA Standard No. 101, and the Davis-Bacon Act. Depending on the final project value, performance and payment bonds may be required, specifically for projects exceeding 35,000 dollars. Final payment is contingent upon the submission of a signed punch list and applicable warranties. All inquiries and submissions are managed by Purchasing Agent Katie Curran.
Education Training & Resources LLC

POSTED

about 14 hours ago

DEADLINE

in 4 days
NAICS: 238160
New
International
Columbine Community Centre - Roof Renewal Works, Walton On The Naze
Solicitation # FWTC-COL-ROOF-2026
Frinton & Walton Town Council is seeking tenders for the design, supply, and installation of a roof over-cladding or renewal solution at The Columbine Community Centre in Walton-on-the-Naze. The project, valued between 150,000 and 200,000 GBP excluding VAT, includes the installation of a replacement roofing system with minimum 0.7mm profiled steel sheeting and 260mm fibreglass insulation to meet Building Regulations Part L. A critical component of the scope is the full conversion of existing internal concealed rainwater goods to a new external gutter and downpipe system. The works are estimated to take place from December 17, 2026, to January 30, 2027, and must be executed while maintaining safe public access to the occupied building. The contract is reserved for UK suppliers, with a particular suitability for small and medium-sized enterprises. Participation requires a mandatory site visit and current health and safety accreditation such as CHAS, SafeContractor, or Constructionline. Award criteria are weighted at 50% for price, 25% for technical quality, 10% for the programme, 10% for health and safety compliance, and 5% for experience. Successful bidders must provide comprehensive insurance coverage, including 10 million GBP for public, products, and employers' liability. Payment terms include monthly interim applications paid within 30 days, with a 5% retention held, half of which is released at practical completion and the remainder after a 12-month defects liability period. Tenders are due by November 6, 2026, at 12:00 pm.
Frinton & Walton Town Council

POSTED

about 14 hours ago

DEADLINE

in about 2 months
NAICS: 238160
New
Federal
USDA-ARS Mississippi Roofing Repairs - Multi Locations
Solicitation # 12445126B0042
Solicitation 12445126B0042 is an Invitation for Bid for two roofing projects in Mississippi, issued as a total small business set-aside under NAICS code 238160. The government intends to award firm-fixed-price contracts to the lowest responsive and responsible bidder who can complete the work within 90 days of the notice to proceed. The performance period is scheduled from September 28, 2026, to December 31, 2026. The scope of work is divided into two packages. Package 1174723 involves the preparation and application of a GAF Roof Coating System on buildings 27, 29A, 35, and 36 at the USDA ARS MS State facility in Starkville, including partial roof replacement for building 29A. Package 1174574 requires the supply and installation of 53 roof vent boots and VentSaver kits at the ARS National Biological Control Laboratory Building 80 in Stoneville to repair ice-related damage. Key requirements include a bid guarantee for individual or combined packages and performance and payment bonds totaling 100% of the award price, due 10 days after the award. Contractors must submit a site-specific safety plan within seven days of the award and adhere to Davis-Bacon Act wage standards. Bids must be submitted electronically by September 18, 2026, and include a signed SF1442, completed Schedule B forms for both packages, and a scanned bid guarantee.
Csa East 11 Usda-Fs

POSTED

about 18 hours ago

DEADLINE

in 6 days
NAICS: 238160
New
Federal
Z--Free Quaker Meeting House, Roof Repair, Conservati
Solicitation # 140D0426Q0825
Solicitation 140D0426Q0825 is a Request for Quote issued by the Department of the Interior's Interior Business Center for the replacement of the terra cotta tile roof and the repair, conservation, and selective replacement of exterior building components at the Free Quaker Meeting House in Independence National Historical Park, Philadelphia. This project is a Total Small Business set-aside under NAICS code 238160, with an estimated magnitude between 1,000,000 and 5,000,000 dollars. The scope of work includes the installation of a custom Ludowici interlocking clay tile roof system, zinc and tin-coated copper flashings, historic wood conservation, masonry repointing, and exterior painting. All work must adhere to the Secretary of the Interior’s Standards for the treatment of historic fabric and National Park Service requirements. The contract requires completion within 20 weeks of the Notice to Proceed, with liquidated damages set at 5,600 dollars per calendar day of delay. Award decisions will be based on the most advantageous offer, evaluating price alongside technical factors including the recency and relevancy of past performance within the last five years and the realism of the proposed schedule. Offerors must provide a bid bond per FAR 52.228-1 and comply with Davis-Bacon Act wage determinations. Following three amendments to correct site visit details and extend deadlines, the final response due date is September 14, 2026, at 2:00 PM ET. Quotes must be submitted electronically to the designated Contracting Officer and Contract Specialist.
Ibc Acq Svcs Directorate (00004)

POSTED

about 18 hours ago

DEADLINE

in 3 days
NAICS: 238160
New
Federal
DISA FY26 ROOF REPAIRS AT FORT MEADE, MARYLAND
Solicitation # W912DR26QA057
Solicitation W912DR26QA057 is a competitive, firm-fixed price contract issued by the U.S. Army Corps of Engineers, Baltimore District, for roof repairs at the DISA Headquarters complex at Fort Meade, Maryland. This total small business set-aside under NAICS 238160 is estimated between 1,000,000 and 5,000,000 dollars and will be awarded based on the Lowest Price Technically Acceptable process. The scope of work includes inspecting and repairing EPDM roofing across six buildings and associated structures, resetting lightning protection aerials, repairing or replacing gutters, and sealing cracks in exposed concrete foundation walls. The project duration is 545 calendar days from the notice to proceed, with all work performed during normal business hours in accordance with Unified Facilities Criteria and Guide Specifications. Due to the secure nature of the DISA facility, the contract mandates stringent security requirements. All personnel must be U.S. citizens with a minimum Secret security clearance verifiable in DISS, or be provided with a contractor-funded escort. The contractor must maintain a valid Facility Security Clearance and CAGE code, and personnel are required to complete mandatory training, including AT Level I, iWATCH, OPSEC, and TARP. Personally owned electronic devices are prohibited within the facility unless a waiver is granted. Amendment 0001 specifically provides site visit information, scheduling an organized visit for August 26, 2026, to facilitate contractor site investigation.
W2SD Endist Baltimore

POSTED

about 18 hours ago

DEADLINE

in 6 days

AI Contract Overview

Show more

The contract requires Design/Build services to repair, upgrade, and modernize Building 562 at RAF Alconbury, focusing on improving the exterior envelope, structural access, and interior lighting and ventilation systems to ensure safety, functionality, and sustainability. The work includes roofing and drainage restoration, corrosion-resistant wall system installation, fenestration upgrades, and compliance with current life safety codes. All work must be executed under a Firm Fixed Price contract with a performance period of 365 calendar days following the Notice to Proceed, which must be issued no later than 30 days after contract award. The delivery destination is clearly defined as APO, AE 09470-5621, United States, with FOB responsibility resting with the contractor. The contract is administered electronically through WAWF for invoicing and payment, with mandatory compliance with MIL-STD-129 for packaging and MIL-STD-130 for item-level marking, requiring 2D Data Matrix symbols to encode unique identifiers for all qualifying items. The evaluation is conducted under a Lowest Price Technically Acceptable framework, where proposals must achieve at least ACCEPTABLE in Technical Capability—including a detailed Project Plan and Safety Plan—and SATISFACTORY in Past Performance, with award going to the lowest-priced offeror meeting these thresholds. Offerors must be registered in SAM, possess a valid UEI and CAGE code, and comply with federal clauses governing gratuities, contingent fees, anti-kickback provisions, and restrictions on former DoD officials and convicted felons. Cybersecurity requirements under DFARS 252.204-7012 mandate the safeguarding of covered defense information, while no specific security clearances or key personnel names are stipulated. The solicitation window closes on 17 July 2026, with proposals required to be submitted in three parts: Technical, Past Performance, and Price, though no page limits are imposed. No contract value is disclosed as pricing data remains unspecified in the document, and no formal list of attachments is provided beyond references to an attached Statement of Objectives.

General Info

Design/Build contract for repair and modernization of Building 562 at RAF Alconbury, focusing on sustainability.

Agency

Department Of Defense → FA5570 501 Csw RcoView Agency

NAICS

238160 - Roofing ContractorsView NAICS

Place of Performance

AE, GBR

Set-Aside

NONE

Documents

(11)

Building Survey Draft June 2010 - Housing Supply Warehouse Building 562

PDFother

ALCO01000562 Asbestos Management Survey Report for RAF Alconbury

PDFsurvey-report

FY 2024 Repair Housing & Dormitory Warehouse Project Drawing RAF Alconbury

PDFdrawing

AEDY20-1007 Statement of Objectives for RAF Alconbury Building 562 Repair

PDFstatement-of-objectives

AEDY_00562 Floor Zone Table Survey June 2010

PDFspecifications

AEDY_00562_1 Floor Zone Table and Area Survey

PDFother

RFI Response for Building 562 Renovation Project

DOCXrfi-response

Attachment 1 - Section L and M Instructions and Evaluation Factors

PDFinstructions-and-evaluation

Solicitation FA557026R0002 Warehouse Repair RAF Alconbury

PDFrfp

Building 562 Asbestos Report

DOCXother

Attachment 1 - Section L and M Proposal Instructions and Evaluation Factors

PDFinstructions-and-evaluation

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

3 updates
PhaseClosed
Posted

Solicitation

Amendment 1

Contract was updated

Amendment 2

Contract was updated

Amendment 3

Contract was updated

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA5570 501 Csw Rco
Contacts2 people available
OfficeAPO, AE, 09470-5720, USA
Organization / Agency
Department Of Defense → FA5570 501 Csw Rco
View Agency Profile
Office AddressAPO, AE, 09470-5720, USA

Full Description

Show more

The requirement is for Design/Build services to repair, upgrade,
and modernize Building 562 at RAF Alconbury. The Government seeks innovative, cost-effective, and
sustainable solutions to improve the facility's exterior envelope, structural access, and interior lighting/
ventilation conditions.


PLEASE SEE ATTACHED STATEMENT OF OBJECTIVES FOR MORE DETAILS 

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS