This Solicitation opportunity from Department Of Defense was posted on April 29, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
WATER SAMPLING TEST
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
The contract solicitation SPE2DH-26-T-3513 requests the procurement of water sampling test reagent for fluoride determination using the HACH SPADNS 2 Method 10225 with AccuVac ampules, specified to meet EPA compliance standards and be equivalent to SM 4500-FD for drinking water and wastewater reporting programs, with a measurement range of 0.02 to 2.00 mg/L F. The product is to be supplied in packages of 25 ampules per PG, with a total order quantity of 2 PG. All items must comply with the DLA Master List of Technical and Quality Requirements, and packaging must adhere to commercial standards as outlined in Medical Marking Standard No. 1, superseding MIL-STD-129. Each unit must be sealed in a protective container, and shipping containers must ensure safe delivery at the lowest freight rate to Fort Irwin, CA. A critical requirement is that the reagent must have a shelf life of 60 months, with no more than eight months elapsed from the date of manufacture to delivery. Shelf-life markings must include the date of manufacture, expiration date, contract number, and lot number, in accordance with MMS1C. Hazardous communication standards under OSHA’s revised HCS mandate the submission of GHS-compliant Safety Data Sheets and labels prior to award, and suppliers must train staff on these requirements. The product is classified as a TYPE I (CODE S) item with non-extendable shelf life and falls under hazardous material handling protocols per IP025. Delivery is required within 20 days of award, with FOB destination terms, and items must be shipped to the specified location at Fort Irwin. The contracting office is the Department of Defense’s Medical Supply Chain FSH, and award will be made based on technical compliance, cybersecurity readiness assessed via NIST SP 800-171, past performance through SPRS, and price reasonableness, using a best-value trade-off approach. All offers must be submitted electronically via the DIBBS portal by May 6, 2026, and must include UEI and CAGE codes, size status certifications, and affirmations regarding compliance with whistleblower protections, defense information safeguards, and prohibitions on covered telecommunications equipment. The contract employs fixed-price terms under FAR 52.216-1 with Alternate I and incorporates numerous clauses including cybersecurity, hazardous materials, packaging,
General Info
Agency
NAICS
Place of Performance
PO BOX 105109, FORT IRWIN, CA, 92310-5109, USASet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
WATER SAMPLING TEST REAGENT,FLUORIDE
FOR DETERMINATION OF FLUORIDE BY HACH SPADNS 2 METHOD 10225, USING
ACCUVAC AMPULES. THE SPADNS 2 REAGENT FORMULATION REMOVES INTERFERENCE
FROM CHLORINE WITHOUT ARSENIC. EPA COMPLIANT FOR USE IN DRINKING WATER
AND WASTEWATER REPORTING PROGRAMS AND EQUIVALENT TO THE EPA REFERENCE
METHOD SM 4500-FD;
RANGE: 0.02 2.00 MG/L F
UNIT ISSUE: PG (25 EA PER PACKAGE)
..
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE
DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB
AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
..
RD003, COVERED DEFENSE INFORMATION POTENTIALLY APPLIES
..
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
..
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
..
APPLICABLE TO ALL MEDICAL ACQUISITIONS:
PACKAGING AND PACKING SHALL BE COMMERCIAL AS
SPECIFIED IN THE PROCUREMENT DOCUMENT.
EACH COMPLETE UNIT SHALL BE PROPERLY PACKAGED
IN A SUITABLE SEALED UNIT CONTAINER CAPABLE
OF PROTECTING THE CONTENTS FROM DAMAGE AND/OR
BREAKAGE.
UNITS SHALL BE PACKED IN SUITABLE COMMERCIAL
EXTERIOR (SHIPPING) CONTAINERS (EXPORT WHEN
NECESSARY) WHICH SHALL INSURE ACCEPTANCE AND
SAFE DELIVERY BY COMMON OR OTHER CARRIER, AT
THE LOWEST RATE, TO POINT OF DELIVERY CALLED
FOR IN THE CONTRACT OR ORDER.
MATERIAL MUST BE MARKED IAW MEDICAL MARKING
STANDARD NO. 1. THIS SUPERCEDES ALL REFERENCES
TO MIL-STD-129.
COPIES OF MEDICAL MARKING STANDARD NO. 1
(MMS NO. 1) MAY BE OBTAINED BY CONTACTING DLA
TROOP SUPPORT VIA EMAIL TO fssb@dla.mil. MMS NO. 1 IS ALSO AVAILABLE ONLINE AT:
SPE2DH-26-T-3513
SECTION B
https://www.dla.mil/Logistics-Operations/Packaging/
.. RS023: Shelf-life requirement RS001 for a TYPE I (CODE S) item with a shelf life of 60 months (non-extendable) applies to this item.
SHALL HAVE A SHELF LIFE OF 60 MONTHS.
NOT MORE THAN 8 MONTHS SHALL HAVE ELAPSED FROM
DATE OF MANUFACTURE TO DATE OF DELIVERY TO THE
GOVERNMENT.
.
SHELF LIFE MARKINGS SHALL BE IN ACCORDANCE WITH
THE LATEST REVISION OF MMS1C.
. ALL LABELS SHALL INCLUDE:
DATE OF MANUFACTURE, EXPIRATION, OR RETEST DATE
CONTRACT NUMBER/LOT NUMBER.
..
RQ034: HAZARDOUS COMMUNICATION STANDARD NOTICE
Hazard Communication Standard Notice:
Effective June 1, 2015, Federal Standard No. 313-E, Material Safety Data, Transportation Data and Disposal Data for Hazardous Materials Furnished to Government Activities, establishes the requirement for preparation and submission of Safety Data Sheets (SDS) in lieu of Material Safety Data Sheets (MSDS) by suppliers who provide hazardous materials to government activities.
The Occupational Safety and Health Administration (OSHA) has modified its Hazard Communication Standard (HCS) to conform to the United Nations Globally Harmonized System of Classification and Labeling of Chemicals. As a result of this change, GSA revised Federal Standard No. 313-E requiring Safety Data Sheets for classifying chemicals and communicating the applicable information on labels.
In accordance with the revised standard after June 1, 2015:
1. Suppliers will be required to submit, to the contracting officer for review and approval prior to award, safety data sheets consistent with the requirements found at 29 C.F.R. 1910.1200 for hazardous materials delivered to the Government.
2. Suppliers will also be required to submit, to the contracting officer for review and approval prior to award, Hazardous Communication Standard (HCS) labels in accordance with 29 C.F.R. 1910.1200 requirements or current Consumer Product Safety Act (CPSA), Federal Hazardous Substance Act (FHSA) labels when subject to labeling requirements under those statutes. This product labeling is required for hazardous materials delivered to the Government.
3. Finally, suppliers must train their employees on the new safety data sheets, hazardous communication labels, and requirements of 29 C.F.R. 1910.1200.
For more information on SDS, refer to OSHAs website, available at:
https://www.osha.gov/law-regs.html
For information on 29 C.F.R. 1910.1200, refer to the below link:
https://www.osha.gov/dsg/hazcom/index.html .. BIDDER: PLEASE SPECIFY SOURCE AND PART NUMBER BEING SUPPLIED.
ADEQUATE DATA FOR THE NSN/Part Number: 6630-01-706-4234 Quantity: 2 PG Purchase Request: 7016559929QTY: 2 Delivery: 20 days ADO
More opportunities from Department Of Defense → MEDICAL SUPPLY CHAIIN FSH
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS