Weatherproofing Units

Open
N6339427Q4006Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

NAICS

238390 - Other Building Finishing Contractors

Place of Performance

NSWC PHD, 4363 Missile Way, Port Hueneme, CA 93043, CA, 93043

Set-Aside

SBA

Documents

1
PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Commanding Officer
Contacts1 person available
OfficePORT HUENEME, CA, 93043-5007, USA
Office AddressPORT HUENEME, CA, 93043-5007, USA

Full Description

Show more
To address facility workspace capacity requirements at Naval Base Ventura County, forty-one (41) wood-framed modular workspace units have been procured and will ultimately be assembled within a designated facility structure. The modules are currently stored outdoors in designated staging areas pending final installation. This requirement is for the procurement, delivery, and on-site assembly of heavy-duty, non-chemical weatherproofing systems to protect the modular units from environmental degradation during temporary outdoor storage, including rain, wind, ultraviolet exposure, and marine moisture in a coastal environment. The required system is a complete turnkey weatherproofing solution for forty-one (41) stored modular units consisting of thirty (30) 12 feet x 36 feet units and eleven (11) 12 feet x 16 feet units. The system must be custom-fitted on-site and provide durable, tightly secured, weather-resistant protection from the bottom chassis to the roofline, while excluding the bottom 3-foot poly stilts from coverage. Individual wrapping is the standard approach; however, grouped wrapping of adjacent modules may be considered where site conditions or unit spacing make individual wrapping impracticable, provided the same level of protection and performance is maintained. Functionally, the weatherproofing system supports preservation of the modular units structural condition and serviceability during long-term outdoor storage until installation. The system must be suitable for coastal outdoor exposure, resist UV degradation and salt-spray weathering, withstand high-wind conditions in accordance with manufacturer-approved installation guidance, and avoid damage to the modular units through unapproved penetrating attachment methods. The requirement also includes full surface preparation, precision fitting and sealing, quality assurance verification, and recurring maintenance inspections every sixty (60) to ninety (90) days for twelve (12) months after acceptance to ensure continued weather-tightness and identify any moisture intrusion or system degradation.

Similar Contracts

Same NAICS industry code

More opportunities from Department Of Defense → Commanding Officer

Same awarding agency

NAICS: 811310
New
Federal
Hydrostatic Testing
Solicitation # M6740027Q0001
The Department of Defense, through the Commanding Officer at Marine Corps Air Station Iwakuni, is soliciting a firm fixed price contract for the hydrostatic testing of 81 Amerex B674 Wheeled Halotron I Fire Extinguishers. Performance is scheduled to take place between January 15, 2027, and March 15, 2027, either at Marine Corps Air Station Iwakuni or another mutually agreed upon location. All testing and visual examinations must strictly adhere to NFPA 10, CGA C-1, CGA C-6, and DOT Title 49 CFR Part 180 standards. The contractor is responsible for ensuring structural integrity through 100 percent inspection, maintaining specific expansion limits for low pressure cylinders, and providing detailed marking and labeling including the test date, pressure used, and the identity of the testing agency and individual. Interested offerors must submit their quotations by November 30, 2026, at 0800 JST, with all inquiries directed to the primary point of contact by November 16. Submissions must include a quotation with full pricing, a technical approach not exceeding three pages that details logistical plans and testing methodology, and a one page summary of relevant past performance from the last five years. Award will be granted to the responsible offeror deemed most advantageous to the government based on technical acceptability and price reasonableness. Administrative requirements include active SAM registration and electronic invoicing via the Wide Area WorkFlow system.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

1 day ago

DEADLINE

in 23 days
View Details
NAICS: 611699
New
Federal
NOTICE OF INTENT TO SOLE SOURCE
Solicitation # M67400-27-N-0001
The Marine Corps Installations Pacific Regional Contracting Office intends to award a sole-source contract to Skydive Elsinore for commercial tactical training support services to benefit the 3d Reconnaissance Battalion, 3d Marine Division. This requirement, categorized under NAICS 611699 and PSC U013, focuses on Military Free Fall progression and sustainment training. The period of performance is scheduled from November 28 to December 18, 2026, in Lake Elsinore, California. The acquisition is being conducted as a FAR Part 12 acquisition under the Simplified Acquisition Threshold, with a total estimated value not expected to exceed that threshold. The scope of work requires the contractor to provide DoD Commercial Airlift Review Board approved aircraft configured for High-Altitude High-Opening and High-Altitude Low-Opening operations, capable of operating up to 14,000 feet AGL with a rear ramp exit. Facility requirements include at least 2,000 square feet of secure, climate-controlled classroom and storage space, shaded parachute packing areas with rubber matting, and on-site overnight lodging for up to 35 personnel. Additionally, the contractor must provide certified drop zone liaisons and FAA-certified parachute rigging and packing services. All operations must comply with Marine Corps Order 3120.11A and applicable federal hazardous material regulations.
All Other Miscellaneous Schools and Instruction

POSTED

4 days ago

DEADLINE

in 6 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS