Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity was posted on November 23, 2004. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Y -- DESIGN BUILD SENSOR TEST TRACK

Closed
SST-00002-CC-05Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 236210
New
Federal
F-15EX 8-Bay Maintenance Hangar Complex-Industry Day
Solicitation # W50S8527H1CU0
The National Guard Bureau is seeking market intelligence for the construction of an aircraft maintenance hangar complex at Selfridge Air National Guard Base in Harrison Township, Michigan. This project supports 21 Primary Aircraft Authorization F-15 EX aircraft and is estimated to have a magnitude between 150 million and 200 million dollars. The scope includes the demolition of buildings 3, 5, 117, and 120, with new parking constructed in the footprints of buildings 117 and 120. The construction may be executed in three phases: Hangar 1, a 2-bay corrosion control and fuel cell hangar; Hangar 2, a 4-bay maintenance hangar; and Hangar 6, a 2-bay munitions and training facility. The project also requires necessary utility and infrastructure upgrades. The government is considering a fixed-price agreement utilizing an Other Transaction Agreement under the authority of 10 U.S.C. 2808a, with funding potentially provided in annual phases of approximately one-third of the total cost. Technical requirements include compliance with DoD antiterrorism and force protection standards, adherence to Air Force and base design standards, and specialized foundations to meet flood plain requirements. Design is anticipated to be 100 percent complete by early 2027. This notice is for planning purposes only and is not a formal solicitation. Interested firms under NAICS code 236210 must provide company details, bonding capacity, and evidence of experience with aviation facilities and constrained-site construction to the designated points of contact by the response deadline of December 1, 2026.
W7NF Uspfo Activity Miang 127

POSTED

2 days ago

DEADLINE

in about 1 month
NAICS: 236210
New
SLED
Facilities & Parks New Supply Warehouse Building
Solicitation # ITB FM 04-27
The Board of County Commissioners of Okaloosa County, Florida, is soliciting bids under ITB FM 04-27 for the construction of a new 9,000 square foot metal supply warehouse for the Facilities and Parks Department located at 5489 Old Bethel Road in Crestview. The project involves comprehensive site preparation and construction, including the installation of energy-efficient HVAC systems, electrical and plumbing work, and telecommunications wiring. All work must comply with the 2023 8th Edition Florida Building Code, ADA standards, and OSHA regulations, with specific structural requirements to withstand 160 MPH ultimate wind speeds. A fire alarm system is explicitly not required for this project. Bids must be submitted electronically via OpenGov by November 4, 2026, at 3:00 pm CST. The contract will be awarded to the responsive and responsible vendor with the lowest bid, though the County reserves the right to negotiate the most advantageous agreement. The selected contractor must provide a dedicated project manager and furnish both bid and performance bonds. The project timeline is 12 months from the notice to proceed. Payment will be processed through the County Finance Office in accordance with the State of Florida Local Government Prompt Payment Act, contingent upon annual appropriation. For projects involving federal grant funding, contractors must be registered in SAM.gov and comply with Buy America and Trafficking Victims Protection Act requirements.
Facilities & Parks

POSTED

7 days ago

DEADLINE

in 5 days

AI Contract Overview

Show more

Bechtel Nevada is seeking a General Contractor for the design and construction of a sensor test track facility at the Nevada Test Site in Mercury, Nevada. The project requires a straight-line track approximately 100 meters long featuring a bi-directional, computer-controlled carriage. This carriage must transport a small radioactive source at variable heights and adjustable speeds ranging from 1 m/s to 15.6 m/s, with integrated sensors to provide time-stamped speed and height data to a stationary collection point. Interested parties must submit pre-qualification materials by December 15, 2004, to be considered for the formal Request for Proposal in January 2005. Evaluation criteria include design capabilities, safety records via OSHA and MSHA history, a quality assurance program meeting DOE standards, and at least five years of similar project experience. Additionally, any successful subcontractor must agree to the Bechtel Nevada Project Labor Agreement for Construction.

General Info

Bechtel Nevada seeks a contractor for a sensor test track facility in Mercury, Nevada.

Agency

N/A

NAICS

236210 - Industrial Building Construction

Place of Performance

Nevada Test Site, Area 6, Nye County, Nevada on Federal land controlled by the National Nuclear Security Administration (NNSA)

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
ContactsNo contacts available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Bechtel Nevada is seeking General Contractor sources that can provide for the design and construction of the following facility at the Nevada Test Site, Area 6, Mercury, Nevada. One facility with options of motor driven wheeled vehicle or linear motor powered carriage are envisioned. Consists of a straight-line track of seller's design approximately 100 meters long passing between loading-dock-height portal mounting platforms (designed and installed by others). The facility will include a bi-directional carriage capable of carrying a softball sized radioactive source from 0.25 feet to 16 feet above the platform surface on a mast with a maximum source weight of ~2 kg. It will be capable of transporting the radioactive source at controllable speeds past multiple sensors (by others) with the source installed at variable vertical heights. No change of source height is required during carriage motion. The carriage will be capable of remote computer-controlled and pre-programmed speed and direction. Velocity capability is from 1 m/s to 2.2 m/s within - 10% for current standard with capability to travel at 15.6 m/s for future standards tests. Stated in other units, the speed must be adjustable from slow walking speed (~2 miles per hour) to 35miles per hour. Carriage should repetitively run the following cycle: Accelerate to chosen speed in a minimum distance, maintain that speed for 30 meters centered on the test platform, decelerate in a similar distance, reverse and repeat the process in the opposite direction. Sensors capable of determining the speed and height of the source on the moving carriage and delivering that information with time stamping to a stationary data collection point are to be included. Life operating and maintenance cost will be a consideration. ****Any resultant subcontract will require the contractor to be signatory to Bechtel Nevada Project Labor Agreement for Construction. This agreement can be found at the following site: http://www.bechtelnevada.com/ppmgt/const_main.htm**** It is anticipated the formal Request for Proposal package will be issued in January 2005 to pre-qualified sources. INTERESTED PARTIES WISHING TO PRE-QUALIFY FOR RECEIPT OF A PROPOSAL PACKAGE WILL BE EVALUATED BY SUPPLYING THE FOLLOWING INFORMATION IN ACCORDANCE WITH THE BELOW LISTED EVALUATION CRITERIA NO LATER THAN DECEMBER 15, 2004. Pre-Qualification Evaluation Criteria: 1. Design Capabilities: Provide a complete Standard Form 330, - Architect-Engineering Qualifications which identifies company qualifications demonstrating capabilities to fulfill the requirement identified in the description above. 2. Safety Experience: The proposer must demonstrate the effectiveness of its Safety and Health programs by providing a copy of their program. In addition a 36 month OSHA violation and accident history (or the history this company has available); its 36 month MSHA violation and accident history (or the history this company has available); the MSHA Total Incident Rate. The evaluation will focus on the Offeror's Interstate Experience Modification Rate (EMR) for the three most recent years and the use of the Offeror's OSHA and MSHA history for the last three reported years. An EMR rate greater than one may be cause for rejection. 3. QA/QC Program: The proposer must submit an implemented Quality Assurance Program commensurate with the scope of the activities for the required work to meet the requirements of DOE Order 414.1A. 4. Company Experience/Past Performance: Proposer and any lower'tier subcontractors (if applicable) shall have a minimum of five (5) years experience and shall demonstrate company experience in projects similar to this requirement. Provide number of years the company has been in business and similar projects current and within the past 5 years. Past Performance information shall include project description, dollar magnitude, completion date (if the date was extended the circumstances), contract number, and point of contact information. 5. Key Personnel: Provide a listing of key personnel with functional responsibilities which adequately addresses the disciplines as described in the requirement. Submit resumes for the management team (Project Manager/Superintendent), Design Engineers, and Safety Representatives. Identify whether certifications are currently held by the proposed staff or must be obtained, i.e., Nevada registered Engineers, etc.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS