Y1DA--CON 668-21-100 Upgrade AHUs 18-20-22 Mechanical Systems
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
This contract amendment, identified as Amendment 0004 to solicitation 668-21-100, pertains to the upgrade of Air Handling Units (AHUs) 18, 20, and 22 at the Mann-Grandstaff VA Medical Center in Spokane, Washington, under the designation Y1DA--CON 668-21-100. The work involves mechanical system upgrades, complete ceiling replacement including grid and tiles, application of fireproofing materials per Section 078100, and asbestos abatement based on an environmental sampling report. Fireproofing must meet specific density requirements of 40 lb. per cubic foot in mechanical rooms, with surfaces requiring cleanliness and manufacturer inspection and approval prior to, during, and after application. Installation must occur in phases with controlled access, and work hours are strictly limited to 0700–1600, with coordination necessary near inpatient areas due to noise constraints. Materials must be delivered in sealed, labeled containers showing manufacturer name, brand, and UL certification, stored off the ground and under cover, and any damaged or water-exposed materials must be removed immediately. A test area, including at least 15 feet of beam and deck and one column, must be installed at a location selected by the Contracting Officer’s Representative (COR) and approved by both the COR and the manufacturer’s representative before proceeding with further work. This test area must undergo bond and density tests in accordance with ASTM E736, and all fireproofing must be independently tested by a COR-approved laboratory at the contractor’s expense. Laboratories performing testing must be accredited, and fire endurance tests must comply with ASTM E119 at a nationally recognized facility. The contractor must provide a dedicated Site Safety and Health Officer who cannot perform other roles, and while the VA will coordinate the relocation of users, the contractor is responsible for moving furnishings within the space and establishing temporary power in the provided laydown yard as needed. This procurement is a Service-Disabled Veteran-Owned Small Business Set Aside under NAICS Code 238220, with a solicitation posted on May 29, 2026, and responses due by June 8, 2026. The contracting office is located in Vancouver, Washington, with the place of performance in Spokane, WA 99205. All existing terms and conditions remain unchanged, and no pricing or contract value details are provided
General Info
Agency
NAICS
Place of Performance
WA, 99205Set-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
Amendment 0004 to address RFIs.
More opportunities from Department Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS