Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

TURNER, RAMIREZ AND ASSOCIATES, INC.

UEI: MK1FBNRMQME5CAGE: 57UQ9

TURNER, RAMIREZ AND ASSOCIATES, INC. is a federal contractor, registered under UEI MK1FBNRMQME5 and CAGE code 57UQ9. It has been awarded $25,224,398 in federal contracts. Primary work spans Commercial and Institutional Building Construction, Plumbing, Heating, and Air-Conditioning Contractors, and Electrical Contractors and Other Wiring Installation Contractors. Top awarding agencies include Department Of Defense, Department Of Agriculture, and Other agencies (1 agencies, <0.5% each).

Contact Information

Registration and classification details

Registration

UEI Code

MK1FBNRMQME5

CAGE Code

57UQ9

Entity Structure

Corporate Entity (Not Tax Exempt)

Established

N/A

Business Classifications

For Profit OrganizationSubchapter S CorporationHispanic American OwnedMinority-Owned BusinessSelf Certified Small Disadvantaged Business

NAICS Codes

236115New Single-Family Housing Construction (except For-Sale Builders)
236116New Multifamily Housing Construction (except For-Sale Builders)
236210Industrial Building Construction
236220Commercial and Institutional Building Construction(Primary)
237110Water and Sewer Line and Related Structures Construction
+8 more

Federal Contracting Overview

Award totals, agency breakdown, NAICS distribution, and geographic footprint.

AI Capability Profile

Turner, Ramirez and Associates, Inc. specializes in commercial and institutional building construction with a focused expertise in facility modernization, structural repairs, and infrastructure upgrades for defense installations. Their work includes HVAC system retro-commissioning, DDC control repla...

Turner, Ramirez and Associates, Inc. specializes in commercial and institutional building construction with a focused expertise in facility modernization, structural repairs, and infrastructure upgrades for defense installations. Their work includes HVAC system retro-commissioning, DDC control replacements, emergency switchgear upgrades, fence expansions, ramp reconstructions, and exterior building repairs—all performed on active military and government facilities. The contractor demonstrates hands-on proficiency in integrating building automation systems, executing precision electrical and mechanical retrofits, and delivering mission-critical infrastructure repairs under operational constraints. Their technical approach emphasizes reliability, compliance with military construction standards, and minimal disruption to ongoing operations, making them a trusted partner for lifecycle maintenance of federal facilities. The company maintains a consistent relationship with the Department of Defense, delivering construction and repair services across multiple installations, including barracks, recreational centers, and administrative buildings. Their projects often involve urgent or time-sensitive repairs requiring coordination with base engineering and facilities management teams, indicating a deep familiarity with DoD procurement protocols and installation-specific requirements. Primarily operating under NAICS 236220, the firm focuses on the construction and renovation of institutional structures, with supplemental experience in fabricated wire products for perimeter security fencing and minor electrical and plumbing integrations. This positions them as a niche provider of integrated facility support services rather than a general contractor, with an emphasis on durability, safety, and regulatory compliance in high-security environments. Based in Corpus Christi, Texas, Turner, Ramirez and Associates, Inc. is a small, locally rooted business with no federal certifications. Their geographic proximity to key DoD installations supports rapid mobilization and on-site responsiveness, reinforcing their role as a dependable regional partner for defense infrastructure sustainment.

Key performance metrics

Award counts and award dollars by type, as prime and as subcontractor.

Awards Count

25

All time

Active

2

Currently performing

Completed

23

Past period of performance

Total Awards

All time

Contracts

Prime · all time

Subcontracts

Sub · all time

Grants

Prime · all time

Subgrants

Sub · all time

Award analytics

Awards by agency, industry, year, award type, size, and place of performance.

Awards by Agency
Department Of Defense$24.3M96.4%Department Of Agriculture$853.4K3.4%
Awards by NAICS
Awards by Agency Over Time
Awards by Place of Performance

Compete with TURNER, RAMIREZ AND ASSOCIATES, INC.

Track the contractors you bid against, and the work they win

Award history, agency mix, and NAICS coverage for TURNER, RAMIREZ AND ASSOCIATES, INC.

AI-powered matching against your own capabilities and past performance

Teaming and subcontracting signals on every award

Automated alerts when a competitor wins in your market

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS

Open opportunities in TURNER, RAMIREZ AND ASSOCIATES, INC.'s top NAICS codes and agencies

NAICS: 236220
New
SLED
Building 262 Renovations FLETC Glynco
Solicitation # 70LGLY27RSSB00001
The Building 262 Renovation project at the Federal Law Enforcement Training Center (FLETC) in Glynco, Georgia, is a comprehensive interior modernization effort. The scope of work includes replacing corridor and classroom flooring with LVP and carpet tiles, fully renovating restrooms by replacing vanities and lavatories, and updating doors and life-safety components. Technical upgrades involve installing a low-profile raised flooring system with electrical distribution for classrooms, replacing variable air volume (VAV) systems using Automated Logic Corporation components, and upgrading lighting controls and ballasts. The project also requires repainting interior surfaces, installing new signage, and correcting plumbing deficiencies. This procurement is a Total Small Business Set-Aside under NAICS code 236220. The period of performance is scheduled from January 11, 2027, to March 11, 2028, with a total delivery timeline of 425 calendar days after the notice to proceed. Proposals are evaluated based on three equally weighted factors: Past Performance, Corporate Relevant Experience, and Price. The contractor must provide payment and performance bonds totaling 100% of the contract price and adhere to strict security and background check requirements, including FBI fingerprinting and DHS non-disclosure agreements. All work must comply with ADA/ABA accessibility guidelines and the FLETC Hazardous Waste Management Plan.
Bristol Alliance of Companies

POSTED

about 8 hours ago

DEADLINE

in 13 days
View Details
NAICS: 236220
New
SLED
Repair Auto Maintenance Bldg 575
Solicitation # N40085-27-R-9000
Solicitation N40085-27-R-9000 covers the repair and modernization of the Auto Maintenance Facility, Building 575, at MCB Camp Lejeune, North Carolina. The scope of work is comprehensive, involving selective demolition, building envelope and roofing repairs, interior reconfiguration, and the installation of new finishes. Technical upgrades include new HVAC systems, exhaust extraction, compressed air systems, a full NFPA-compliant fire suppression system, and updated electrical distribution, lighting, and building automation controls. Additionally, the project encompasses site improvements such as paving, drainage upgrades, and hazardous materials abatement. The project is estimated to cost between $10 million and $25 million with a performance period of 730 days, with the award based on the lowest price. Bidders must provide pricing for two primary exhibit line items: building renovation and the removal and replacement of paving. The contract requires strict adherence to various standards, including MIL-STD-101 for piping identification and ADA accessibility guidelines. Administrative requirements include the use of Wide Area WorkFlow for invoicing and the submission of monthly work-hour reports and certified payrolls. Bonding requirements vary by proposal value, with bid, payment, and performance bonds required for projects valued at $150,000 or more. Government acceptance is contingent upon a final inspection report submitted 14 days prior to testing, with electrical systems evaluated according to NETA ATS standards.
Bristol Alliance of Companies

POSTED

about 8 hours ago

DEADLINE

in 13 days
View Details
NAICS: 236220
New
SLED
DB Repair Fire Sprinkler Deficiencies, B290, PSNS
Solicitation # N4425527RB007
Solicitation N4425527RB007 is an 8(a) Multiple Award Construction Contract (MACC) task order for a design-build project to repair fire sprinkler deficiencies at Building 290 and the adjoining Building 719 loading dock platform at Naval Base Kitsap, PSNS, in Bremerton, Washington. The contractor is responsible for final design documentation per FC 1-300-09N, labor, supervision, and all materials necessary to resolve critical hazards. Key deficiencies include a Risk Assessment Code Level 4 (RAC-4) deficiency regarding missing sprinklers at the loading dock, unmonitored and unlocked sprinkler control valves in basement elevator pits, and missing backflow preventers on wet pipe sprinkler system risers. Because Building 290 is on the historical register, any exterior modifications require approval from the State Historic Preservation Office (SHPO). The period of performance is 440 days from the award of the task order. Proposals are due by December 2, 2026, at 2:00 PM PST via the PIEE portal and will be evaluated based on price and MACC past performance. Required submissions include a cover letter, a completed schedule of prices, and a bid guarantee of 20 percent of the bid price or $3,000,000, whichever is less. The project mandates strict adherence to safety and technical standards, including EM 385-1-1, the International Plumbing Code, and UFC 3-420-01. Additionally, the contractor must provide a Quality Control Manager, a Site Safety and Health Officer, and comply with FAR 52.219-14 limitation of subcontracting, ensuring no more than 85 percent of the government payment is paid to non-similarly situated entities.
Bristol Alliance of Companies

POSTED

about 8 hours ago

DEADLINE

in 14 days
View Details
NAICS: 238220
New
SLED
Install Pier D High Pressure Air System, NSBREM-724-A
Solicitation # N4425527RB003
The Install Pier D High Pressure Air System project (NSBREM-724-A) is a Design-Build effort located at the Puget Sound Naval Shipyard in Bremerton, Washington. The scope of work involves the design, construction, and commissioning of a permanent high pressure air (HPA) system at Pier D, B724A of Naval Base Kitsap. Key requirements include incorporating the existing HPA cross connection into a system supplied by HPA compressors at the south end of Pier D and providing HPA to shore risers at five specific bollard locations (East #11, #59, #101, and West #47, #59). All new piping must be installed under service grates with all valves located topside. The project is estimated to have a construction magnitude between $1,000,000 and $5,000,000, with a period of performance of 538 calendar days from the date of award. This solicitation is a 100% set-aside for 8(a) businesses located within SBA Region X, which includes Alaska, Idaho, Oregon, and Washington. The basis of award is the proposal determined to be most advantageous to the Government, evaluated based on price only with MACC past performance. The contractor is required to adhere to strict safety and design standards, including EM 385-1-1, UFC requirements, and ASME codes. Security is a primary concern, requiring specific base access badges, background checks, and the integration of cybersecurity for facility-related control systems. Liquidated damages for construction delays are set at $500.00 per calendar day.
Bristol Alliance of Companies

POSTED

about 8 hours ago

DEADLINE

in 13 days
View Details
NAICS: 236220
New
SLED
Modify Transfer Facility NBK Bangor
Solicitation # N44255-25-R-1502
Solicitation N44255-25-R-1502 is a design-build project for the renovation and modernization of Facility #6594 (Transfer Facility) at Naval Base Kitsap Bangor, Washington. The project has an estimated construction magnitude between $10 million and $25 million and involves the demolition and replacement of deteriorated components, the addition of a 400 square foot forklift battery charging area, and the installation of a prefabricated paint booth and new crane systems. A critical requirement of the project is a two-phase execution strategy that ensures the facility remains operational and mission-capable between phases, necessitating multiple mobilization and demobilization cycles. All design documents for both phases must be completed and approved during Phase 1. The project must comply with NAVFAC, UFC, and UFS criteria, as well as Puget Sound Clean Air Agency regulations. Technical requirements include the implementation of cybersecurity standards (ATO), JACE upgrades for UMCS continuity, and strict adherence to IBC, NFPA, and ASTM standards for secure space assemblies and acoustical testing. Proposals are to be submitted via the PIEE portal, with the basis of award being price only combined with MACC past performance. The contract requires the use of the Wide Area WorkFlow (WAWF) system for invoicing and mandates the provision of performance and payment bonds. There is no set-aside status specified for this solicitation.
Bristol Alliance of Companies

POSTED

about 8 hours ago

DEADLINE

in 16 days
View Details
NAICS: 238220
New
Springdale JCC –Recreation HVAC Repair or Replacement
Solicitation # springdale-jcc-recreation-hvac-repair-or-replacement
The Career Systems Development Corporation is seeking quotes for the repair or replacement of two failed 25-ton AAON rooftop HVAC units at the Springdale Job Corps Center recreation building in Troutdale, Oregon. Bidders must provide two separate, itemized quotes for both repair and replacement, including a professional recommendation on the most suitable approach based on cost, unit age, and parts availability. Replacement quotes must be comprehensive, covering all necessary equipment such as cranes, temporary fencing, and ancillary components like curb adapters and hail guards. The project requires an Oregon CCB contractor license and specific warranties, including a one-year workmanship warranty and five-year warranties for the compressor and thermostat. This solicitation is set aside for Small Business (SB), SBA certified Veteran Owned Small Business (VOSB), SBA certified Service-Disabled Veteran Owned Small Business (SDVOSB), SBA certified Women-Owned Small Business (WOSB), and SBA certified HUBZone Small Business (HUBZone SB). The project is subject to prevailing wage laws; replacement work falls under Davis-Bacon Wage Determination OR20260100, R.1, while repair work falls under the Service Contract Act WD 2015-5563, R.28. Quotes must remain valid for 90 days from the RFQ closing date, and any quote totaling $100,000 or more will require Payment and Performance bonds upon award.
Career Systems Development Corporation

POSTED

about 8 hours ago

DEADLINE

in 22 days
View Details
NAICS: 238210
New
26-140 Installation of Emergency Shut Off Switches
Solicitation # 26-140
Solicitation 26-140 is for the installation of emergency shut-off switches on power tools at the Atterbury Job Corps Center in Indiana, operated by Adams and Associates for the U.S. Department of Labor. The scope of work involves installing two mushroom-head push-button emergency shut-off switches and a new 60A, 208/120V, 3-phase, 4-wire, 6-circuit branch circuit panel with a 60A shunt-trip main circuit breaker in the Facility Engineering Storage/Maintenance Shop. All rotating equipment and tool outlets must be reconnected through this new panel. The project requires adherence to FNC guidelines, national building codes, and current EPA and OSHA regulations, with Indiana regulations prevailing if they are more stringent. This is a small business set-aside available to SBA certified Veteran Owned Small Businesses, Service-Disabled Veteran Owned Small Businesses, Women-Owned Small Businesses, and HUBZone Small Businesses. Award will be based on best value using a 100-point system evaluating price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). Bidders must submit a single lump sum bid on official company letterhead, including a detailed cost breakdown, a timeline for substantial completion, and proof of a valid Indiana Contractor's License. A mandatory site visit and pre-bid conference were required for eligibility. The contract includes a one-year workmanship guarantee, Net 30 payment terms, and requires a minimum 90-day bid guarantee.
Atterbury Job Corps. – Adams & Associates

POSTED

about 8 hours ago

DEADLINE

in about 17 hours
View Details
NAICS: 238220
New
Los Angeles Job Corps- Sprinkler Head Repairs
Solicitation # LA JCC Lobby Sprinkler Repairs
Management & Training Corporation is seeking a subcontractor to perform sprinkler head repairs at the Los Angeles Job Corps center located at 1020 South Olive Street, Los Angeles, California. The scope of work involves the installation of one additional fire sprinkler head in the lobby area to extend existing coverage, which includes extending and connecting piping from the existing system above the T-bar ceiling. The contractor is responsible for providing all labor, supervision, materials, and equipment, including the use of a man lift for area access. All work must comply with applicable fire sprinkler installation standards and the Service Contract Labor Standards under Wage Determination number 2015-5613 Rev 31. This is a fee-for-service opportunity with a lump sum bid structure, and the award will be based on best value as determined by Management & Training Corporation. The solicitation is set aside for Small Business (SB), SBA certified Veteran Owned Small Business (VOSB), SBA certified Service-Disabled Veteran Owned Small Business (SDVOSB), SBA certified Women-Owned Small Business (WOSB), and SBA certified HUBZone Small Business (HUBZone SB). Interested offerors must submit a bid sheet, a completed supplier packet including a W-9 and self-certification form, references, and proof of insurance by the deadline of November 23, 2026. Subcontractors are also required to possess a Unique Entity Identification number (UEI) for reporting purposes.
Los Angeles Job Corps

POSTED

about 8 hours ago

DEADLINE

in 5 days
View Details
NAICS: 238220
New
MJCC Multiple HVAC Replacement System
Solicitation # mjcc-multiple-hvac-replacement-system
The Montgomery Job Corps Center is seeking quotes for a subcontracting opportunity to perform a turnkey replacement of multiple HVAC systems at its facility in Montgomery, Alabama. The scope of work involves the removal of existing equipment and the installation of new systems across several buildings, including units ranging from 3.5 to 10 tons. Technical requirements include the use of R-454B refrigerant, specific EER ratings, and a 90% efficiency furnace for certain units. The project requires a testing and balancing service to ensure air-flow meets original designs, and the contractor must provide a 5-10 year warranty on equipment parts and a 2 year warranty on workmanship. All work must comply with the National Electrical Code, NFPA Standard No. 101 Life Safety Code, and OSHA regulations. This opportunity is set aside for Small Business (SB), SBA certified Veteran Owned Small Business (VOSB), SBA certified Service-Disabled Veteran Owned Small Business (SDVOSB), SBA certified Women-Owned Small Business (WOSB), and SBA certified HUBZone Small Business (HUBZone SB). Bidders must provide a current SAM.gov UEI and active registration, Alabama business licenses, a W-9, and an FFATA form. The project is subject to the Davis-Bacon Act, requiring prevailing wages and certified payroll records. Bonding requirements are based on project value, with a 100% payment bond required for projects over $35,000 and both 100% performance and payment bonds required for projects exceeding $150,000. Bids must be submitted by November 27, 2026, at 12:00 PM CST, and must include a detailed cost breakdown, proposed schedule, and certificates of insurance.
Montgomery Job Corps Center

POSTED

about 8 hours ago

DEADLINE

in 8 days
View Details
NAICS: 238220
New
Joliet Job Corps-Request for Quote HVAC Replacement Female Dormitory
Solicitation # joliet-job-corps-request-quote-hvac-replacement-female-dormitory
Management & Training Corporation (MTC), operator of the Joliet Job Corps Center, is soliciting bids for a subcontract to replace the HVAC system in the female dormitory. This fixed-price, single lump sum project has an estimated value between $250,000 and $500,000. The scope of work includes the removal and disposal of ten existing furnace and air conditioning systems and the installation of ten new Carrier systems, along with the integration of a Pelican Building Automation System (BAS) across eleven units. The project is located at 1101 Mills Road, Joliet, Illinois, and is subject to the Davis-Bacon Act, requiring compliance with specific prevailing wage determinations. This opportunity is set aside for Small Business (SB), SBA certified Veteran Owned Small Business (VOSB), SBA certified Service-Disabled Veteran Owned Small Business (SDVOSB), SBA certified Women-Owned Small Business (WOSB), and SBA certified HUBZone Small Business (HUBZone SB). Bids must be submitted by November 23, 2026, and will be awarded based on overall best value. For bids totaling $25,000 or more, a bid bond of 20% is required, and the awarded contractor must provide performance and payment bonds from an A- rated surety company. Required documentation includes a bid breakout, MTC Supplier Self-Certification, and proof of insurance, including general liability of at least $1,000,000 and worker's compensation with employer's liability limits of $500,000.
Joliet Job Corps

POSTED

about 8 hours ago

DEADLINE

in 5 days
View Details
NAICS: 238210
New
Emergency/Exit Lighting – Mechanical/Electrical Rooms Project
Solicitation # emergencyexit-lighting-mechanicalelectrical-rooms-project
Human Learning Systems dba Quentin Burdick Job Corps is soliciting bids for the Emergency/Exit Lighting – Mechanical/Electrical Rooms Project located in Minot, North Dakota. This subcontracting opportunity involves the installation of code-compliant LED emergency and exit lighting to address deficiencies identified in the 2026 Facility Survey for Building 26 (Female Dormitory) and Building 27 (Single Parent Dormitory), specifically focusing on the Main Mechanical/Electrical Room 109. The project requires the contractor to provide all labor, materials, and equipment to ensure a fully operational system that complies with NFPA 101 Life Safety Code, NFPA 70 National Electrical Code, and applicable state and local electrical codes. This opportunity is set aside for Small Business (SB), SBA certified Veteran Owned Small Business (VOSB), SBA certified Service-Disabled Veteran Owned Small Business (SDVOSB), SBA certified Women-Owned Small Business (WOSB), SBA certified HUBZone Small Business (HUBZone SB), and SAM.gov designated entities. Bidders must submit a detailed itemized quotation on the provided bid sheet, along with a current insurance certificate, contractor's license, and any required North Dakota trade licenses. Proposals exceeding $150,000 require a bond. All work must adhere to Davis-Bacon Act prevailing wage requirements. The walk-through is scheduled for November 23, 2026, and sealed proposals must be submitted to Leana Leavitt by December 4, 2026, at 4:00pm CST. Payment terms are Net 30 upon verification of service completion.
Human Learning Systems dba Quentin Burdick Job Corps

POSTED

about 8 hours ago

DEADLINE

in 16 days
View Details
NAICS: 236220
New
Roof Replacement Mandatory Site Visit: 12/03/2026 @ 11 AM
Solicitation # 26-144
This solicitation, number 26-144, is for the full removal and replacement of the roof on Building #1963 LBJ Dorm at the Atterbury Job Corps Center in Indiana, operated by Adams & Associates for the U.S. Department of Labor. The project is necessitated by persistent leaks and requires the contractor to perform a visual inspection to determine the full extent of the replacement. This is a Small Business set-aside, open to SBA certified Veteran Owned Small Businesses, Service-Disabled Veteran Owned Small Businesses, Women-Owned Small Businesses, and HUBZone Small Businesses. A mandatory site visit is scheduled for December 3, 2026, and proposals must be submitted by December 14, 2026. Award will be based on Best Value rather than lowest price, with evaluation weights assigned to price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). Bidders must provide a single lump sum bid with a detailed cost breakdown, a timeline for substantial completion, and a 90-day bid guarantee. Requirements include a valid Indiana Contractor's License, proof of insurance, and certification of compliance with Davis-Bacon Act wage rates. The contractor must adhere to EPA and OSHA regulations, with Indiana state laws prevailing if more stringent. Deliverables include a sequenced construction schedule due 10 days after the Notice to Proceed, a one-year workmanship guarantee, and a two-year manufacturer's product warranty. Payment terms are Net 30.
Atterbury Job Corps – Adams & Associates

POSTED

about 8 hours ago

DEADLINE

in 25 days
View Details