CONTROL BOX, ELECTRICAL

Active
SPE7M4-26-T-363BFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This contract is for the procurement of 14 electrical control boxes for aircraft, identified by NSN 1660-01-525-4405. The items must be cleaned, inspected, processed, and packaged according to ARP1176-V and ASTM D3951. This is a source-controlled critical application item that must be manufactured and tested using limited rights data. Offerors not already cited as acceptable sources must obtain source approval from the design control activity and submit a Source Approval Request package. Key compliance requirements include CMMC Level 2 self-assessment, adherence to DLA master lists of technical and quality requirements, and strict prohibition of Class I ozone-depleting chemicals. The contractor is responsible for any costs associated with converting digital mylar data to stable base formats while maintaining specific dimensional accuracy tolerances. Inspection and acceptance will occur at the origin, with delivery required within 160 days to the DLA Distribution Depot at Tinker AFB.

General Info

DLA Land and Maritime seeks 14 electrical control boxes for delivery by September 2026.

Agency

Department Of Defense → FLUID HANDLING DIVISIONView Agency

NAICS

336413 - Other Aircraft Parts and Auxiliary Equipment ManufacturingView NAICS

Place of Performance

3301 F AVE CEN REC BLDG 506 DR 22, TINKER AFB, OK, 73145-8000, USA

Set-Aside

NONE

Documents

(1)

SPE7M4-26-T-363B Request for Quotations

PDFrfq

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseSolicitation
Posted

Combined Synopsis

Type Changed

Combined Synopsis → Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FLUID HANDLING DIVISION
Contacts1 person available
OfficeUSA
Organization / Agency
Department Of Defense → FLUID HANDLING DIVISION
View Agency Profile
Office AddressUSA

Full Description

Show more
CONTROL BOX,ELECTRICAL-ELECTRONIC,AIRCRA
CONTROL BOX, ELECTRICAL
Clean, inspect, process and package IAW ARP1176-V referenced in the USAF SAW doc in DMS.
RD004: Cybersecurity Maturity Model Certification (CMMC) Level 2 Self-Assessment
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS (IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
RC001: DOCUMENTATION REQUIREMENTS FOR SOURCE APPROVAL REQUEST (SAR)
RD002, COVERED DEFENSE INFORMATION APPLIES
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
RQ001: TAILORED HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
(MANUFACTURERS AND NON-MANUFACTURERS)
RQ002: CONFIGURATION CHANGE MANAGEMENT ENGINEERING CHANGE PROPOSAL
REQUEST FOR VARIANCE (DEVIATION OR WAIVER)
RQ006: QUALITY CONFORMANCE INSPECTION REQUIREMENTS
RQ009: INSPECTION AND ACCEPTANCE AT ORIGIN
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
Item Unique Identification is not required by request of the Service customer. DFARS 252.211-7003(c)(1)(i) applies.
RT001: MEASURING AND TEST EQUIPMENT
SPE7M4-26-T-363B
SECTION B
OFFERORS NOT CITED AS ACCEPTABLE SOURCES IN THE
PURCHASE ORDER TEXT ARE REQUIRED TO
OBTAIN SOURCE APPROVAL FROM THE DESIGN CONTROL
ACTIVITY. SOURCE APPROVAL REQUESTS/TECHNICAL
DATA PACKAGES MUST BE SUBMITTED TO DSCR WITH
THE OFFER.
DIGITAL MYLAR DATA EXISTS FOR THIS NSN, AND WILL BE INCLUDED IN THE
TECHNICAL DATA PACKAGE PROVIDED BY DLA. IF UNABLE TO USE THE DATA IN
THE DIGITAL FORMAT PROVIDED, THE CONTRACTOR WILL BE RESPONSIBLE FOR
HAVING THE DATA CONVERTED TO THE NECESSARY FORMAT (I.E. MYLAR FILM),
THROUGH A THIRD PARTY AND BEAR THE ASSOCIATED COSTS WHEN CONVERTING FROM
DIGITAL TO STABLE BASED FORMAT, THE DIGITAL MYLAR SHALL BE PLOTTED ON
STABLE BASE MATERIAL, WHILE MAINTAINING THE DIMENSIONAL ACCURACY DEMANDS
OF THE UNDIMENSIONED DRAWING.
THIS INCLUDES BUT IS NOT LIMITED TO: VERIFY THE PLOT OF THE MYLAR(S) FOR
DIMENSIONAL ACCURACY AS OUTLINED IN ASME Y14.31. ACCURACY SHALL BE
DETERMINED VERTICALLY, HORIZONTALLY AND DIAGONALLY. ENSURE THAT THE
INDIVIDUAL GRID UNITS ARE WITHIN THE TOLERANCE OF (+,-) 0.005 INCHES AND
(+,-) 0.007 INCHES DIAGONALLY. TOTAL GRID TOLERANCE SHALL BE (+,-)
0.010 INCHES AND (+,-) 0.014 INCHES DIAGONALLY. DRAWINGS WITH
DIMENSIONAL ACCURACY POINTS SUCH AS TRAMMEL POINTS SHALL BE MEASURED TO
WITHIN CENTERLINE (+,-) 0.010 INCHES AND (+,-) 0.014 INCHES DIAGONALLY.
REGISTRATION MARKS SUCH AS THOSE USED ON CIRCUIT CARDS SHALL BE MEASURED
TO WITHIN (+,-) 0.005 INCHES AND (+,-) 0.007 INCHES DIAGONALLY.
SAMPLING:
THE SAMPLING METHOD SHALL BE IN ACCORDANCE WITH MIL-STD-1916 OR ASQ
H1331, TABLE 1 OR A COMPARABLE ZERO BASED SAMPLING PLAN UNLESS OTHERWISE
SPECIFIED BY THE CONTRACT. IF THE APPLICABLE DRAWING, SPECIFICATION,
STANDARD, OR QUALITY ASSURANCE PROVISION (QAP) SPECIFIES CRITICAL, MAJOR
AND/OR MINOR ATTRIBUTES, THEY SHALL BE ASSIGNED VERIFICAITON LEVELS OF
VII, IV AND II OR AQLS OF 0.1, 1.0 AND 4.0 RESPECTIVELY. UNSPECIFIED
ATTRIBUTES SHALL BE CONSIDERED AS MAJOR UNLESS SAMPLING PLANS ARE
SPECIFIED IN APPLICABLE DOCUMENTS. FOR MIL-STD-1916, THE MANUFACTURER
MAY USE THE ATTRIBUTE OR VARIABLE INSPECTION METHOD AT THEIR OPTION OR
PER THE CONTRACT. MIL-STD-105/ASQ Z1.4 MAY BE USED TO SET SAMPLE LOT
SIZE, BUT ACCEPTANCE WOULD BE ZERO NON-CONFORMANCES IN THE SAMPLE LOT
UNLESS OTHERWISE SPECIFIED IN THE CONTRACT.
THIS IS A SOURCE CONTROLLED ITEM WHICH MUST BE
MANUFACTURED AND TESTED IN ACCORDANCE WITH THE
CITED LIMITED RIGHTS DATA. THE GOVERNMENT CAN
NOT PROVIDE THE DATA. ONLY THOSE VENDORS WHO
HAVE ACCESS TO THE DATA OR CAN PROVIDE TRACE
ABILITY TO THE APPROVED SOURCES SHOULD QUOTE.
SAR PACKAGE IS REQUIRED IF YOUR COMPANY IS
CONSIDERING SOURCE APPROVAL.
CLASS I OZONE DEPLETING CHEMICALS ARE NOT TO BE
USED NOR INCORPORATED IN ANY ITEMS TO BE
DELIVERED UNDER THIS CONTRACT.THIS PROHIBITION
SUPERSEDES ALL SPECIFICATION REQUIREMENTS BUT
DOES NOT ALLEVIATE ANY PRODUCT REQUIREMENTS.
SUBSTITUTE CHEMICALS MUST BE SUBMITTED FOR
APPROVAL UNLESS THEY ARE AUTHORIZED BY THE
SPECIFICATION REQUIREMENTS.
CRITICAL APPLICATION ITEM
MISSION SYSTEMS DAVENPORT INC. 99251 P/N 1653330-2
SPE7M4-26-T-363B
SECTION B
PR: 7017913319 PRLI: 0001 CONT’D
DLA issues this document using the DoD authorized unit of issue, please refer to the following URL to determine the corresponding ANSI X12 unit of issue.
https://view.officeapps.live.com/op/view.aspx?src=https%3A%2F%2Fwww.dla.mil%2FPortals%2F104%2FDocuments% 2FDLMS%2FeApplications%2FLogDataAdmin%2FUnitofIssueandPurchaseUnit.xlsx&wdOrigin=BROWSELINK
CLIN PR PRLI UI QUANTITY UNIT PRICE TOTAL PRICE.
0001 7017913319 0001 EA 14.000
NSN/MATERIAL:1660015254405
DELIVERY (IN DAYS):0160
DELIVER FOB: ORIGIN
QTY VARIANCE: PLUS 0% MINUS 0%
INSPECTION POINT: ORIGIN
ACCEPTANCE POINT: ORIGIN
PREP FOR DELIVERY:
PKGING DATA-QUP:001
WILL BE PACKAGED IN ACCORDANCE WITH ASTM D3951.
All DLA Master List of Technical and Quality Requirements take precedence over ASTM D3951. Mark and label all packaging and packing in accordance with MIL-STD-129. The Unit of Issue (U/I) and Quantity per Unit Pack (QUP) will be as specified in the contract/purchase order. PALLETIZATION SHALL BE IN ACCORDANCE WITH RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
PARCEL POST ADDRESS:
SW3211
DLA DISTRIBUTION DEPOT OKLAHOMA
3301 F AVE CEN REC BLDG 506 DR 22
TINKER AFB OK 73145-8000
US
FOR TRANSPORTATION SEE DLAD DLAD PROC NOTE C19. FOR FIRST DESTINATION TRANSPORTATION SEE DLAD PROC NOTE
C20 AND CONTRACT
FREIGHT SHIPPING ADDRESS:
SW3211
DLA DISTRIBUTION DEPOT OKLAHOMA
3301 F AVE CEN REC BLDG 506 DR 22
TINKER AFB OK 73145-8000
US
Need Ship Date:02/12/2027 Original Required Delivery Date:12/12/2027
SPE7M4-26-T-363B NSN/Part Number: 1660-01-525-4405 Quantity: 14 EA Purchase Request: 7017913319QTY: 14 Delivery: 160 days ADO