Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on August 29, 2007. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

23--Request 4 each Mobile Instrumentation Support Vans MISV

Awarded
W9115U-07-T-0056Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 336211
New
SLED
This solicitation is to provide quotes to Reverse Auction for 14 Type 6 Engine beds to be built for the purpose of wildland fire fighting with MS Forestry Commission.
Solicitation # 1451-27-R-RFQF-00001
The Mississippi Forestry Commission is soliciting quotes via a reverse auction for the complete upfit of fourteen Type 6 wildland fire engines. The project involves furnishing and installing apparatus bodies, emergency warning equipment, electrical systems, and 300-gallon wildland firefighting skid units onto fourteen 2026 Ram 5500 crew cab chassis provided by the commission. All completed units must be delivered to the state office in Pearl, Mississippi, within nine months of the accepted bid date. The contract is awarded to the lowest responsible bidder who meets all technical specifications, including the requirement to provide CAD design drawings for approval before fabrication begins. Key technical requirements specify that plumbing must use TIG-welded stainless-steel manifolds with Grade 5 stainless steel hardware, and the skid units must adhere to strict dimensional and weight limits. Bidders must certify that they are not suspended or debarred from federal assistance programs and must provide detailed component descriptions and manufacturer warranties at delivery. The state is exempt from federal, state, and local taxes. The contract may be canceled by the commission with 30 days' written notice, and any subcontracting requires prior written consent. Responses are due by November 16, 2026, and can be submitted through the MAGIC e-procurement system or via paper submission.
MS FORESTRY COMMISSION

POSTED

1 day ago

DEADLINE

in 15 days

AI Contract Overview

Show more

This solicitation seeks quotes for the procurement of four Mobile Instrumentation Support Vans (MISV) based on Ford E-Series LWB or equivalent specifications. The vehicles must be 4WD with 6.0 liter diesel engines, extended tops, and specialized modifications including heavy-duty insulation, rubber floor matting, a roof deck, and a GSA-approved field safe. Technical requirements include a roof-mounted air conditioner/heater, a power inlet changeover switch for external or generator power, and specific interior finishes such as static-resistant gray carpeting. The contract is divided into three line items: the delivery of the four vans to Fort Bliss, Texas, within 90 days of award; a one-day on-site operations seminar for five personnel; and a one-year maintenance agreement requiring a response to equipment defects within 12 hours. Award will be granted to the technically acceptable lowest offer on an all-or-nothing basis. Interested respondents must be registered in the Central Contractor Registration and submit all costs by the deadline of September 10, 2007.

General Info

Contract Value

$476,628

NAICS

336211 - Motor Vehicle Body Manufacturing

Place of Performance

US Army ATEC Contracting Activity ATTN: CSTE-CA, P.O. Box Y Fort Hood TX 76544-0770, TX, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Combined Synopsis

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W6QM Micc-Fdo Ft Hood
ContactsNo contacts available
OfficeFORT HOOD, TX, 76544, USA
Office AddressFORT HOOD, TX, 76544, USA
ContactsNo contact information available

Full Description

Show more
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6 and Subpart 13.5 Simplified Acquisition Procedures Test Program. This solicitation document and incorporated provisions and clauses a re those in effect through Federal Acquisition Circular 2005-17. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation shall not be issued. This combined synopsis/solicitation serves as the request for q uotes for the following three CLINs: CLIN 0001: 4 (each) Mobile Instrumentation Support Van (MISV) consisting of the following specifications: The vehicle shall be a 4WD standard enclosed type vehicles, Ford van E Series LWB and Supervan or equal with e xtended top, under full manufacturers warranty. The vehicle shall be supplied with complete two (2) sets of manufacturers specifications, and operator and service manuals on all parts of the vehicle and the vehicle themselves. Two (2) sets of keys shall be delivered with the vehicle. The vehicles shall at a minimum have a wheel base of 138 inches. The Engine shall be 6.0 liter diesel engine with a minimum displacement of 415 cubic inches. The drive train shall be four wheel drive, with automatic front l ocking hubs. The wheels and tires shall be 16 inch, all terrain, steel belted radial, type 235/85RX16E or equivalent. The chassis gross vehicle weight rating (GVWR) shall minimally be 9,400 pounds. The minimum payload capacity shall be 3,590 pounds (162 8 kg.) minimum. The vehicle shall have heavy duty shock absorbers on the front and rear. The alternator shall be single serpentine belt driven, with a minimum of 130 amps. The transmission shall be heavy duty automatic with three forward speeds plus overd rive, and one reverse gear minimum. The steering shall be power assist with tilt wheel/ cruise control and front stabilizer bar. The brakes shall be heavy duty, power assisted; 4 wheel ABS, 4 wheel disk. The fuel tank capacity shall be a minimum of 27 US g allons. The vehicle shall have an electronic ignition system. The vehicle shall have a high capacity air conditioner in front. There shall be no more than seven (7) windows on each van. The front, drivers and passengers door glass shall be tinted; all other windows shall be blocked in such a way as to keep out external light. The drivers door and passenger door shall have factory installed power windows and door locks with the master control located on the right side panel behind the side door, and a control for each window in the actual door panel where it is located. The illuminated instrument cluster shall consist of the following gauges at a minimum: Speedometer, Odometer, Fuel level, Voltmeter, Ammeter, and Engine oil pressure. The lights shal l minimally include a headlight ON warning lamp, under hood lamp, courtesy lights for all doors, and each courtesy lights shall have on/off switches located on it. The windshield wipers shall be intermittent with a windshield washer, and its capacity sha ll be a minimum of 70 fluid ounces (4.9 L). All doors shall be power locked and keyed alike where practical. The vehicles shall have cruise (speed) control and adjustable tilt steering wheel. The Government shall provide a sample of paint for vendor matc hing and finish, and the vehicle shall be exterior finish shall match the sample provided. The van top shall be an extended Viking Sport Top or equal and shall not have any windows. The vehicle shall have a heavy duty ladder capable of supporting 400 lbs (181kg) and shall be attached to the left rear door to allow access to the roof. The floors shall be raised to allow hard packed fiberglass insulation to be installed between the factory metal floor in the operations area and the 1/2 (12.5mm) plywood su b floor. The van subfloor shall be covered with  (12.5mm) plywood. The plywood shall be covered with 1/8 (3mm) commercial grade rubber floor matting, FLEXC O Microflex MRS-280 or equivalent. Custom Structural drilled and tapped steel plates shall be installed as required in the floors to provide ridged support for equipment racks. The vans shall be completely insulated with industry standard hard packed comm ercial insulation in the interior floor, sides, and roof. The interior walls shall consist of 3/8 plywood which shall cover the insulation. The carpet shall be gray in color, closed loop, static resistant and commercial grade, glued to the plywood. The ceiling shall be constructed in such a way as to cover the hard packed insulation. The covering shall be gray in color, closed loop; static resistant commercial grade carpet shall cover the ceiling interior. The van body shall be undercoated for durabili ty. All areas of the vehicle body subject to the entrance of dust and water shall be sealed with a long-life flexible sealant. The towing package shall include a 3.55 ratio differential, a heavy duty turn signal flasher, a heavy duty, large capacity radi ator, dual heavy duty batteries, heavy duty front and rear springs, front and rear stabilizer bars, a 2 tow hitch with receiver and 2 ball. The bumpers shall be OEM type. The vehicle shall have 1/16 (1.5mm) steel skid plates protecting the engine oil p an, transmission and gasoline tanks. The front and rear axles shall be reinforced to prevent damage due to operation in rough off-road terrain at maximum gross vehicle weight. The vehicle shall have an external roof air conditioner/heater modified with ho t gas by-pass valve mounted on the roof of the van. The hot gas by-pass modification provided shall eliminate loading as a result of a locked rotor compressor startup during normal operation. The unit shall conform to the following minimum specifications: a 15,000 BTU cooling capacity, a 5,600 BTU heating capacity, a 300CFM (while cooling) air flow rate, the unit shall not draw more than 17 amps at any time, the unit shall not exceed 110 pounds (50 kg) installed, the unit shall not be over 9 3/4 (247mm) in height, 28 (711mm) in width and 42 (1067mm) in length, and the unit shall operate on 120VAC/60Hz/ Single phase. Electrical power shall be provided with the van using a towed generator providing 120VAC/60Hz. Two 3 prong male twist lock marine grade ch rome plated brass connector with screw on covers boxes, with covers shall be mounted flush in the lower right rear curb side wall of the vehicle. The plugs shall be wired into the circuit breaker panel and be capable of a 30 amp load at 120VAC. A 50 foot [15m] power cord with a marine grade 3 prong female twist lock mating plug on one end and a regular 3 prong male connector on the other shall be provided. The plug and receptacle shall incorporate a sensor system that shall trip an alarm if the plug is le ft in place and the vehicle is placed in any gear except park and neutral. A power inlet changeover switch shall be installed and wired into the power system. This switch shall to be able to be switched manually to either the generator power output or to the external AC power, provided by an external AC source through the 50 foot [15m] power cable. The switch shall have an indicator to show what position it is in. One aluminum lockable blank interconnect panels shall be mounted flush on the vehicle to pro vide interfaces between antennas and internal equipment cabling. The panels shall be approximately 12 inches [305 mm] long and 12 inches [305 mm] high. The panels shall extend through the interior wall and shall be flush with the wall. The panel shall be l ocated in the center road side wall behind instrumentation racks with final location to be specified by the end user. Two seats shall be provided consisting of driver and passenger seats. Seats shall conform to the following specifications: All seat fabric shall be heavy duty, wear tested, soil resistant cloth, Seat color shall be gray and shall be color coordinated with the carpet, a limited amount of vinyl mate rial shall be acceptable on the sides, front and rear of the seat, the seat chairs shall be able to slide forward a minimum of six inches with equally spaced dented stop positions, the driver and front passenger seat shall be installed in their original po sitions, the passenger seat shall be swivel mounted to conform to slop in passenger floor. One  length roof deck shall be constructed on the roof of the vehicle above the extended top. The deck shall be constructed of a non-skid aluminum surface with a 1 aluminum rail completely surrounding the deck. The rail shall be attached 6 above the deck floor. The deck shall extend - the width of the vehicle top, and shall be mounted to the metal body of the vehicle for support and grounding purposes. The de ck shall have a minimum clearance of 4 above the extended van top, and shall be level with the vehicle floor. The deck shall be mounted on the top of the vehicle roof, starting at the mid roof line and shall extend rearward top the rear edge of the roof. The deck shall be capable of supporting, without any sag, a minimum of 300 pounds of weight at any location on the deck. A GSA approve two drawer field safe shall be installed and attached to the vehicle frame. The location of the field safe shall be f inalized during the initial coordination meeting. The contractor shall coordinate within 2 business days ARO, the date, time and location for a Post award Conference. This coordination shall be made by the contractor, with the COR and the ADATD represent atives. Monthly In-Process Review (IPR) Meetings shall be held with the COR and other ADATD representatives at the contractors site. The final acceptance test in accordance with the PWS shall be conducted on all vehicles by the COR and other ADATD repre sentatives upon delivery of the vehicles to Fort Bliss, Texas. The contractor shall notify the COR a minimum of 10 business days prior to the delivery of the vehicles to the ADATD. All completed vehicles shall be delivered to ADATD within 90 days ARO. The contractor shall deliver the MISV FOB Destination. CLIN 0002: (Training) The contractor shall provide a 1 day on-site operations seminar on equipment for 5 people, at Ft. Bliss, Texas, to be established by the COR and other ADATD representatives. The G overnment shall notify the contractor minimally 30 days prior to the training date. CLIN 0003: (Maintenance) The contractor shall be available to come to Ft. Bliss to repair equipment defects within 12 hours of notification for a period of one year. Th is date will be established upon the completion of the Government acceptance of all vehicles. The basis for award is technically acceptable lowest offer. The Government will make a single award based on this announcement which will be based on all or nothi ng. The NAICS code is 336211 with a size standard of 1000 employees. Each response received shall be used at the sole discretion of the Government to determine if it meets the business requirements; however only quotes received by the date outlined in thi s solicitation shall be considered. All respondents shall be registered in the Central Contractor Registration (CCR), have a valid DUNS number, Cage Code, and Tax Identification Number. Provisions at FAR 52.212-1, Instructions to Offers-Commercial and FAR 52.212-4, Contract Terms and Conditions-Commercial Items apply to this acquisition. Offerors need to include a complete copy of the provisions at FAR 52.212-3, Offeror Representations and Certifications-Commercial Items with their quote. The clause at 52.2 12-5, Contract Terms and Conditions required to implement Statues of Executive Orders-Commercial Items, applies to this acquisition. Clauses include: 52.211-6, Brand Name or Equal; 52.222-26, Equal Opportunity; 52.222-35, Affirmative Action for Disabled Ve terans and Veterans of the Vietnam Era; 52.222-36, Affirmative Action for Workers with Disabilities; 52.222-37, Employment Reports of Disabled Veterans and Vete rans of the Vietnam Era; 52.232-33, Payment by Electronic Funds Transfer-Central Contractor Registration and DFARs Clause 252.212-7000 Offeror Representations and Certifications  Commercial Items and 252.242-7000 Post Award Conference. All responsible so urces may submit a quote, which shall be considered for the award. All costs must be included in the quote. Quotes are due on or before 4:30pm Central Standard Time, Monday, 10 September 2007. POC is David Higginbottom at +1 (555) 000-0000 or david.higginbott contact@example.gov or fax +1 (555) 000-0000. If quotes are submitted by fax, the contractor shall have the sole responsibility of ensuring their fax is clear and legible. Mailing address is: ATEC Mission Support Contracting Office, P.O. Box Y, Fort Hood TX 76544 . Anticipated award date is Monday, 17 September 2007.

More opportunities from Department Of Defense → W6QM Micc-Fdo Ft Hood

Same awarding agency

NAICS: 334210
New
Federal
WSMR Tel Switch Support
Solicitation # 058669
The Range Operations Directorate at White Sands Missile Range, New Mexico, is seeking information for a sources-sought effort to provide technical support for one Nortel CS2100 and three CS1000M telephone switches. The objective is to ensure voice traffic is transported securely within information assurance and mission safety parameters. The anticipated 12-month period of performance runs from November 30, 2026, to November 29, 2027. This request is currently an RFI to explore market capabilities and is not a formal solicitation or commitment to purchase. The scope of work requires the contractor to provide 24/7 remote telephonic technical support through ESP Tier II and Ribbon Tier III licenses, which must be delivered within 30 days of award. Additionally, the contractor must conduct three on-site visits per year, occurring every four months, with each visit consisting of 24 hours of on-site troubleshooting, diagnostics, and system restoration. Technical tasks include fixing and retrieving telephone switch files in the STORM Server, clearing switch faults, and potentially replacing internal server hardware. Compliance requirements include adherence to FAR clause 52.204-9 for personal identity verification and meeting NCIC-III and Terrorist Screening Database standards for installation access. Contractors must also complete iWATCH Army program training within 15 days of award and maintain detailed trouble ticket logs to track system failures. The effort is categorized under NAICS code 334210 and is managed by the W6QM Micc-Fdo Ft Hood.
Telephone Apparatus Manufacturing

POSTED

3 days ago

DEADLINE

in 9 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS