Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on February 17, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

4110--VA Loma Linda CBOC Pharmacy Refrigerators

Closed
36C26226Q0379Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

Place of Performance

Department of Veterans Affairs VA Loma Linda Healthcare System, Loma Linda, AZ, 92357

Set-Aside

NONE

Documents

1

RFI 36C26226Q0379 VA Loma Linda CBOC Pharmacy Refrigerators

DOCX, High priority: read this first5 pages · sources-sought
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)
Contacts1 person available
OfficeGilbert, AZ, 85297, USA
Office AddressGilbert, AZ, 85297, USA
Contacts
Melissa RamirezContracting Specialist

Full Description

Show more
THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION. SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT/RFI DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 333415 (size standard of 1.250 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published. The Department of Veterans Affairs (VA) is seeking sources capable of providing pharmacy refrigerators equivalent to brand Helmer Scientific. CLIN DESCRIPTION QTY UOM 0001 Helmer Scientific iSeries Pharmacy Refrigerator Part# iPR125-GX or equal 3 EA
SALIENT CHARACTERISTICS
CLIN 0001 Helmer Scientific iSeries Pharmacy Refrigerator iPR125-GX or equal Quantity: 3EA
Refrigerators must be medical grade with a certificate if regulatory compliance. Must have a touchscreen with user interface that is password protected and provides advanced monitoring and information to ensure protection of stored product. Must have audible and visual alarms that include: power failure, high and low temperature alarms, door ajar, condenser temperature, and low battery alerts. Must have adjustable audio alarms with the ability to raise, lower, and mute volume. Must be able to display temperature in Celsius or Fahrenheit and be able to track temperature history. Must be able to download temperature history as well as data logging via USB or other removable media to keep for performance records. Must contain ventilated shelves and ventilated drawers that can hold up to 100 lbs. At a minimum, must maintain temperatures between +2°C to +10°C to meet proper storage temperature requirements. Must be certified to NSF/ANSI 456 Vaccine Storage Standard. Must have at least/minimum of 25 cubic feet capacity to be able to hold a sufficient amount of IV refrigerated medications. Refrigerators dimensions must not exceed 29 inches external width, 79.6 inches external height, and 34.2 inches in depth due to storage space. Must have locking casters to allow ease of movement for cleaning. Must come with NEMA 5-15 hospital-grade power cord to properly fit plug ins. Must have a minimum of one glass door with ADA compliant full-length handle. Mut include flexlock ready handles to accommodate Omnicell FlexLock system.
The list of pharmacy refrigerator characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. If your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Incomplete responses to the questions below this notice will not be accepted. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Submit your capabilities statement illustrating how your organization can/cannot meet the SALIENT CHARACTERISTICS. For instances where your company cannot meet the SALIENT CHARACTERISTICS, please explain. For instances where your company can meet the SALIENT CHARACTERISTICS requirement(s), please show how your company meets/exceeds each requirement. (2) Please review the SALIENT CHARACTERISTICS and provide any additional feedback or suggestions. If none, please reply as N/A. (3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc. (4) Is your company considered small under the NAICS code identified in this RFI? (5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of SALIENT CHARACTERISTICS? (6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available). (7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified. (8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6? (9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items? (10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? (11) Please indicate whether your product conforms to the requirements of the Buy American Act? (12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate. (13) What is estimated life span of your solution? What support/services does that entail? (14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained. (15) Does your organization offer a leasing solution? Please elaborate. (16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s). (17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract. (18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. (19) Please provide your SAM.gov Unique Entity ID/Cage Code number. Responses to this notice shall be submitted via email to contact@example.gov. Telephone responses will not be accepted. Responses must be received no later than Wednesday, February 25th, 2026 by 10:00 AM Pacific Local Time. All responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.

More opportunities from Department Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)

Same awarding agency

NAICS: 562211
New
Federal
F999--Hazardous Material & Waste Disposal
Solicitation # 36C26227Q0071
The Department of Veterans Affairs, through Network Contracting Office 22, has issued a sources sought announcement under solicitation number 36C26227Q0071 to identify qualified contractors for hazardous material and waste management services. This is a market research effort and not a formal solicitation for award. The scope of work involves providing all labor, materials, equipment, and transportation for hazardous waste disposal, collection, and emergency response services. Performance will take place at the Greater Los Angeles VA Healthcare System West LA Main Campus and various Community Based Outpatient Clinics, including locations in San Gabriel Valley, Santa Barbara, Santa Maria, San Luis Obispo, Bakersfield, and the Captain Rosemary Bryant Mariner clinic. The acquisition is classified under NAICS code 562211 for Hazardous Waste Treatment and Disposal, with a size standard of 47.0 million dollars. In accordance with Public Law 109-461, the government is considering a total set-aside for Service-Disabled Veteran Owned Small Businesses, though it may opt for alternate set-asides or full and open competition based on the responses received. Interested firms must be registered in the System for Award Management and, if applicable, the SBA VetCert system. To be considered, respondents must submit a capability statement detailing their qualifications and past performance from the last five years, along with a completed price schedule for market research purposes. All submissions must be emailed to the contract specialist by November 6, 2026.
Hazardous Waste Treatment and Disposal

POSTED

about 14 hours ago

DEADLINE

in 9 days
View Details
NAICS: 335910
New
Federal
6135--UPS Battery Replacement
Solicitation # 36C26227Q0064
Solicitation 36C26227Q0064 is a firm fixed price request for quotes for the replacement of 60 UPS batteries at the San Diego VA Medical Center, specifically within Building 1 Room BB100-1. This project is a total small business set-aside under NAICS code 335910, with a size standard of 1,250 employees. The scope of work requires the contractor to transition the system to maintenance bypass, implement lock out/tag out procedures on the primary feed, install 60 C&D UPS12-545PLP batteries, and dispose of old batteries at an approved hazardous waste facility. Deliverables include a service report in both hard and electronic copies, a three-year manufacturer warranty, and a one-year installation warranty. All battery terminals must be tightened to a torque specification of 60 In-Lbs. The period of performance is 365 days from the date of award. Offerors must submit their quotes via email to the contracting officer by 15:00 Pacific Local Time on November 10, 2026. Required submission documents include a completed SF 1449 with the vendor's SAM UEI number, a schedule of supplies identifying the specific manufacturer and model, and a certificate of compliance regarding subcontracting limitations. Invoicing must be processed exclusively through the Tungsten Network. The government reserves the right to evaluate offers without discussions and may award to other than the lowest bidder if it is in the public interest.
Battery Manufacturing

POSTED

about 14 hours ago

DEADLINE

in 16 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS