This Sources Sought opportunity from Department Of Veterans Affairs was posted on May 14, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

4130--528A6-25-612 Seeking Sources Two Air-Cooled Chillers Bath VA Medical Center

Closed
36C24225Q0625Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 333415
New
Federal
NSWCCD York Chill Pump Replacement
Solicitation # N0016727Q1002
The Naval Surface Warfare Center, Carderock Division (NSWCCD) is soliciting quotes for the procurement, delivery, and turn-key installation of a replacement pump (Pump No. 1) for York Chiller No. 1 in Building 157. This equipment is critical for providing chilled-water cooling to the Building 13 Server Rooms. The project requires the removal of the damaged pump and the installation of a York Chill Pump, Model YLAA0080SJ46X, Serial SEMM-609950. Due to the proprietary nature of the equipment, the contractor must utilize certified Johnson Controls technicians or representatives. The installation must be completed on or before December 18, 2026, at the NSWCCD facility in Bethesda, Maryland. This is a brand-name restricted procurement under full and open competition and is not set aside for small businesses. The government intends to award a single firm-fixed-price purchase order based on the lowest price technically acceptable method, evaluating quotations on a pass/fail basis for technical requirements and considering past performance via the Supplier Performance Risk System. All quotes must be submitted on official company letterhead, including all-inclusive pricing and business size, and sent via email to the contract specialist and contracting officer by 09:00 AM EDT on November 06, 2026. The contract includes specific requirements for item unique identification per MIL-STD-130 and electronic invoicing through the Wide Area WorkFlow system.
Nswc Carderock

POSTED

about 12 hours ago

DEADLINE

in 18 days
NAICS: 333415
New
DIBBS
41--COOLER UNIT,AIR
Solicitation # SPE8E8-27-T-0446
Solicitation SPE8E8-27-T-0446 is a Request for Quotations issued by DLA Troop Support, Construction and Equipment for the procurement of one air cooler unit, identified by NSN 4130-01-225-1590 and Engineered Coil Company part number FCU-H3-3.5KW-LVP. The requirement is categorized under NAICS code 333415 and is designated as a critical application item. Quotations must be submitted via the DIBBS portal by November 9, 2026. The delivery is specified as FOB Origin with a required delivery date of October 19, 2027, and a lead time of 153 days after order. The item is to be shipped to the DLA Distribution DDSP New Cumberland Facility in Pennsylvania. The contract mandates strict adherence to technical and quality requirements found in the DLA Master List, as well as packaging and marking standards MIL-STD-2073-1E and MIL-STD-129. Special environmental restrictions prohibit the intentional addition of mercury or mercury-containing compounds, except in specific functional applications. Inspection and acceptance will occur at the destination per FAR 52.246-1. Administrative requirements include the use of the Wide Area WorkFlow system for invoicing and compliance with various FAR and DFARS clauses regarding the Buy American Act, cybersecurity safeguarding of covered defense information, and the prohibition of covered defense telecommunications equipment.
DDSP NEW CUMBERLAND FACILITY

POSTED

about 12 hours ago

DEADLINE

in 10 days

General Info

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

Place of Performance

Department of Veterans Affairs Bath VA Medical Center 76 Veterans Ave, Bath, NY, 14810, USA

Set-Aside

NONE

Documents

1

36C24225Q0625 - Two Air-Cooled Chillers Bath VA Medical Center

DOCX, High priority: read this first2 pages · sources-sought
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)
Contacts1 person available
OfficeALBANY, NY, 12208, USA
Office AddressALBANY, NY, 12208, USA
Contacts
Ryan SeburnContract Specialist

Full Description

Show more
Statement of Work Purchasing 2 Air-Cooled Chillers for B 78 CLC 528A6-25-612 Scope: The selected Contractor is to supply two 60-ton, air-cooled, scroll-type chillers for Building 78 (CLC) and two chilled water pumps to replace the existing equipment. Installation work will be performed in-house by VA Shop personnel at the designated job site. The project site is located at the Veterans Affairs Medical Facility in Bath, NY. The provided equipment must meet the specified capacity requirements outlined in the project specification package. The Contractor is responsible for delivering the specified units to the Bath VA Medical Center at 76 Veterans Ave, Bath, NY 14810. VA trades personnel will handle unloading, positioning, and connecting the units to the existing system. The Contractor shall then perform testing, commissioning, and setup of the units in accordance with the manufacturer s recommendations and the project specifications, including programming the units into the existing Building Automation System. Contractor Responsibilities: Contractor must Furnish TWO nominal 60 Ton Air- Cooled Scroll Chillers. Basis of Design Trane CGAM series. Contractor must furnish TWO chilled water pumps. Basis of design B&G e-1510 Base Mounted Pump Series, 2AD 2HP 230/460 1800RPM, the size must be at 132 gpm flow rate and 35 Ft H2o Head loss. Contractor to perform start up must ensure operations and proper integration to existing Trane Tracer Ensemble building management system. Vender must ensure Unit is fully compatible, able to integrate without workarounds and 100% back-net compliant to communicate with Trane Tracer Ensemble building management system. The contractor must deliver the equipment no later than December 31st, 2025. Contractor must follow all the federal regulations and the national and local safety codes while performing any work on the VA property. The Contractor shall coordinate with the COR and the VA utility shops; all the onsite work required for this job to be completed. Work is required to be during workdays normal hours 8:00 AM 4:00 PM, any need to perform any work before or after regular hours or during weekends and holidays, will need to be coordinated in advance with the VA COR.

More opportunities from Department Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS