Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Veterans Affairs was posted on February 18, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

4520--OR Steam Coil Replacement

Awarded
Federal
Submission Closed
Solicitation #
36C24126Q0279

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238220
New
SLED
Install Pier D High Pressure Air System, NSBREM-724-A
Solicitation # N4425527RB003
This Design-Build project involves the design, construction, and commissioning of a permanent high pressure air (HPA) system at Pier D, B724A of Naval Base Kitsap in Bremerton, Washington. The scope of work includes incorporating the existing HPA cross connection into a system supplied from compressors located on the south end of Pier D and providing HPA to shore risers at five specific bollard locations (East bollards 11, 59, and 101, and West bollards 47 and 59). All new piping must be installed under service grates with valves located topside. The project requires a Designer of Record to ensure compliance with Unified Facilities Criteria (UFC), ASME B31.3 for structural integrity, and CGA G-4.1 for hydrocarbon-free verification. The contract is a 100% set-aside for 8(a) businesses located within SBA Region X, covering Alaska, Idaho, Oregon, and Washington. The estimated construction magnitude is between $1 million and $5 million, with a period of performance of 538 calendar days from the date of award. Award will be based on price and MACC past performance. The project is a DO rated order certified for national defense. Key requirements include adherence to EM 385-1-1 safety standards, cybersecurity integration per UFC 4-010-06, and the use of accredited testing laboratories for construction materials.
Bristol Alliance of Companies

POSTED

about 7 hours ago

DEADLINE

in 22 days
NAICS: 238220
New
Federal
Springdale JCC –Recreation HVAC Repair or Replacement
Solicitation # springdale-jcc-recreation-hvac-repair-or-replacement
The Career Systems Development Corporation is seeking quotes for the repair or replacement of two failed 25-ton AAON rooftop HVAC units (Model RH-25-2-00-222) at the Springdale Job Corps Center in Troutdale, Oregon. Bidders must provide two separate, itemized quotes for both repair and replacement, including a professional recommendation on the most suitable approach based on cost, unit age, and parts availability. Replacement quotes must be comprehensive, covering all necessary equipment and services such as cranes, roof supports, curb adapters, and temporary facilities. This opportunity is set aside for Small Business (SB), SBA certified Veteran Owned Small Business (VOSB), SBA certified Service-Disabled Veteran Owned Small Business (SDVOSB), SBA certified Women-Owned Small Business (WOSB), and SBA certified HUBZone Small Business (HUBZone SB). The project is subject to prevailing wage laws, with replacement work falling under Davis-Bacon Wage Determination OR20260100, R.1, and repair work falling under Service Contract Act Wage Determination 2015-5563, R.28. Bidders must provide an Oregon CCB contractor's license number and ensure quotes remain valid for 90 days from the closing date. Payment and Performance bonds are required for any quotes equal to or greater than $100,000. Required warranties include a one-year parts and workmanship warranty, along with five-year warranties for the compressor and thermostat. The response deadline for this solicitation is December 11, 2026.
Career Systems Development Corporation

POSTED

about 7 hours ago

DEADLINE

in 14 days
NAICS: 238220
New
Federal
MJCC Multiple HVAC Replacement System
Solicitation # mjcc-multiple-hvac-replacement-system
The Montgomery Job Corps Center is seeking quotes for a subcontracting opportunity to perform a turnkey replacement of multiple HVAC systems at its facility in Montgomery, Alabama. The scope of work involves the removal of existing equipment and the installation of energy-efficient systems across six designated locations, including units ranging from 3 to 10 tons. Technical specifications require the use of R-454B refrigerant, a minimum EER rating of 16, 90% efficiency furnaces, and Honeywell vision PRO 8000 programmable thermostats. The project includes testing, commissioning, and the provision of a 5-10 year warranty on parts and a 2-year warranty on workmanship. This opportunity is set aside for Small Business (SB), SBA certified Veteran Owned Small Business (VOSB), SBA certified Service-Disabled Veteran Owned Small Business (SDVOSB), SBA certified Women-Owned Small Business (WOSB), and SBA certified HUBZone Small Business (HUBZone SB). Bids must be submitted by December 11, 2026, and must include a detailed cost breakdown, Alabama licensing, certificates of insurance, and active SAM.gov registration with a Unique Entity ID. The project is subject to the Davis-Bacon Act and the Service Contract Act, with bonding requirements based on the total project value. Education & Training Resources (ETR) will serve as the sole judge for the award, and the lowest bid does not guarantee selection.
Montgomery Job Corps Center

POSTED

about 7 hours ago

DEADLINE

in 14 days
NAICS: 238220
New
Federal
Boiler No. 4 Repair– Glenmont Job Corps Center
Solicitation # S26-012
Adams and Associates, Inc. is seeking qualified mechanical contractors for a subcontracting opportunity to repair Boiler No. 4, a Buderus Model 615 cast iron sectional boiler, at the Glenmont Job Corps Center in Glenmont, New York. The scope of work involves the demolition, procurement of OEM materials, installation, and commissioning of two new intermediate boiler sections (#5 and #14) to resolve identified leaks. The contractor is responsible for providing all labor, materials, equipment, and rigging, and must ensure the boiler is restored to a safe, fully operational condition. Key requirements include hydrostatic pressure testing, compliance with OSHA and New York State boiler regulations, and the provision of training and maintenance manuals. This solicitation is set aside for Small Business (SB), SBA certified Veteran Owned Small Business (VOSB), SBA certified Service-Disabled Veteran Owned Small Business (SDVOSB), SBA certified Women-Owned Small Business (WOSB), and SBA certified HUBZone Small Business (HUBZone SB). Proposals must be submitted as a single lump sum on official company letterhead by December 4, 2026, at 5:00 PM ET, and attendance at the mandatory walkthrough on December 2, 2026, is required. Award will be based on best value, evaluated through a 100-point system covering price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). Required documentation includes a valid New York State Contractor's License, W9, vendor questionnaire, and proof of automobile liability insurance.
Adams and Associates, Inc.

POSTED

about 7 hours ago

DEADLINE

in 8 days
NAICS: 238220
New
Federal
Centennial Dry Sprinkler System & Compressor Replacement Services
Solicitation # centennial-dry-sprinkler-system-compressor-replacement-services
Management & Training Corporation is seeking bids for a fixed-price, single lump sum contract to provide dry-type sprinkler system and compressor replacement services at the Centennial Job Corps Center in Nampa, Idaho. The project scope involves engaging a licensed fire sprinkler contractor to eliminate system leaks and replace failing infrastructure in the Men's Dormitory (Building CM), Women's Dormitory (Building CW), and Recreation building (Building D). Key deliverables include the demolition and removal of existing distribution piping and air compressors, followed by the installation of new equipment and rigorous operational and leak testing in accordance with NFPA 25 standards. This opportunity is set aside for HUBZone, Woman-owned, and Service-Disabled Veteran-owned small businesses. Bids are due by December 1, 2026, and must include a detailed cost breakout. For bids of $25,000 or more, a bid bond of 20% is required, and the awarded contractor must provide performance and payment bonds from a surety company with at least an A-rating. The contract is subject to union prevailing wage rates and requires compliance with various FAR clauses, including those regarding security, whistleblower rights, and the Federal Funding Accountability Report (FFATA) for contracts valued at $40,000 or more. Award decisions will be based on overall best value, with a mandatory physical site visit required prior to bid submission.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 7 hours ago

DEADLINE

in 5 days
NAICS: 238220
New
Federal
Dep’t of Labor – Indoor sprinkler system replacement/work
Solicitation # SH26-XXX
The Shriver Job Corps Center is soliciting proposals for the replacement and repair of the indoor fire sprinkler system in Building B located in Devens, Massachusetts. The project is necessitated by freeze damage caused by water remaining in the pipes during winter months in a building that was inaccessible for several years. The scope of work includes replacing the alarm valve, test and drain valves, couplings, and sprinklers, as well as repairing branch lines and performing system integrity tests, including air and hydrostatic tests and a main drain test. The contract is a set-aside for Small Business (SB), SBA certified Veteran Owned Small Business (VOSB), SBA certified Service-Disabled Veteran Owned Small Business (SDVOSB), SBA certified Women-Owned Small Business (WOSB), and SBA certified HUBZone Small Business (HUBZone SB). Award will be based on best value, with evaluation weighted toward price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). Proposals are due by December 8, 2026, and must include a lump sum cost with a detailed breakdown, a timeline for substantial completion, and proof of a valid Massachusetts Contractor's License. Contractors must comply with the Davis-Bacon Act and General Decision Number MA20260001, and adhere to OSHA, EPA, and Massachusetts regulations. The contractor must provide a one-year guarantee of workmanship and maintain specific automobile and workers' compensation insurance, naming Adams and Associates, Inc. as an additional insured.
Shriver Job Corps

POSTED

about 7 hours ago

DEADLINE

in 12 days
NAICS: 238220
New
Federal
CBP#10027 Replace Cafeteria Waste Line & Floor Restoration
Solicitation # CBP#10027
This subcontracting opportunity, solicitation CBP#10027, is issued by Management & Training Corporation (MTC) for the Edison Job Corps Center located in Edison, New Jersey. The project involves a fixed-price, single lump sum contract for the replacement of cafeteria waste lines and subsequent floor restoration. The estimated value of the project is between 0 and 25,000 USD, with a performance period of 30 consecutive business days following the written Notice to Proceed. The contract is set aside for Small Business (SB), SBA certified Veteran Owned Small Business (VOSB), SBA certified Service-Disabled Veteran Owned Small Business (SDVOSB), SBA certified Women-Owned Small Business (WOSB), and SBA certified HUBZone Small Business (HUBZone SB). Bids are due by November 16, 2026, and must be submitted via email to Wendy Lawrence. Required submission materials include the MTC Bid for Lump Sum Contract form signed by an authorized official, a detailed cost breakout on company letterhead covering labor, equipment, fees, bonds, and subcontractors, proof of insurance, and references. The project is subject to Construction Wage Rate Requirements (CWRR), requiring the payment of prevailing wages and the submission of weekly certified payroll reports for payment processing. Additionally, contractors must provide a one-year guarantee of workmanship and adhere to various FAR clauses, including security requirements and the Buy American Act. Award is based on overall best value, with MTC serving as the sole judge of responsiveness.
Edison Job Corps

POSTED

about 7 hours ago

DEADLINE

in 9 days

AI Contract Overview

Show more

This contract involves the replacement of a steam coil in Air Handling Unit 3 at the VA Connecticut Healthcare System’s West Haven VA Medical Center, specifically serving the Operating Room Suite. The project requires the contractor to provide all necessary labor, materials, equipment, and supervision in accordance with the detailed Performance Work Statement. The scope includes removing the existing coil, installing a new face end bypass coil, reconnecting piping and electrical components, performing startup and acceptance testing, and providing a minimum one-year warranty on parts, labor, and workmanship. Work is to be coordinated with VA personnel and conducted during normal business hours, with strict adherence to safety protocols, applicable codes, and VA facility policies. The performance period is 90 calendar days from the Notice to Proceed. This solicitation is a firm-fixed-price award set aside exclusively for Service-Disabled Veteran-Owned Small Businesses under NAICS code 238220, with proposals due by February 25, 2026. Evaluation will be based on price, past performance, and technical capability, requiring contractors to demonstrate relevant experience, quality of personnel trained by the Original Equipment Manufacturer, and ability to expedite manufacturing and installation. No site visits are scheduled, but a mandatory pre-bid walkthrough at the facility is required. Submission of quotes is exclusively electronic, with strict compliance to federal acquisition regulations and provisions for records management and confidentiality. The contract includes specific instructions on submission format, subcontracting, and compliance monitoring to ensure adherence to the scope and performance standards.

General Info

Replace steam coil in AHU 3 at West Haven VA Medical Center, 90-day completion, SDVOSB only.

Contract Value

$63,599

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors

Place of Performance

West Haven VAMC, West Haven, ME, 06516, USA

Set-Aside

SDVOSBC

Award Issued Date

Potential End Date

June 15, 2026

Documents

1
DOCX, High priority: read this first14 pages · rfq
High

Read the document

Every page of every file, in your free workspace.

Read the document

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

View Full Breakdown

This one is closed. Find the next one like it.

Open contracts like this one, right now:

  • Install Pier D High Pressure Air System, NSBREM-724-AOpen now, due in 22 days
  • Springdale JCC –Recreation HVAC Repair or ReplacementOpen now, due in 14 days
See open contracts like this

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

PhaseAwarded
Posted

Combined Synopsis

Awarded

Contract was awarded

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)
Contacts1 person available
OfficeTOGUS, ME, 04330, USA

Full Description

Show more
VA Connecticut Healthcare System OR Steam Coil Replacement Page 2 of 2
Combined Synopsis Solicitation West Haven VAMC Steam Coil Replacement (i) This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. (ii) The solicitation number is 36C24126Q0279 and the solicitation is issued as a request for quotation (RFQ). (iii) A statement that the solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2025-06. (iv) This requirement is being issued as a SDVOSB set-aside. The associated NAICS 238220 and small business size standard is $19.0 million. (v) The Government intends to award a firm-fixed price award for Steam Coil Replacement at the West Haven VAMC. Please see the attached Performance Work Statement for full requirement details. Please complete the Price Schedule below and submit with the quote submission. (vi) The Contractor shall provide all resources necessary to provide Steam Coil Replacement IAW the attached (Performance Work Statement). Please see the attached PWS for full requirement details. (vii) The Place of Performance is West Haven as described per the (Performance Work Statement). (viii) Provision at 52.212-1, Instructions to Offerors -- Commercial, applies to this acquisition in addition to the following addenda s to the provision: 52.252-1 Solicitation Provisions Incorporated by Reference (FEB 1998); 52.204-7 System for Award Management (OCT 2018); 52.204-16 Commercial and Government Entity Code Reporting (JUL 2016); 52.217-5 Evaluation of Options (JUL 1990); 852.252-70 Solicitation Provisions or Clauses Incorporated by Reference (JAN 2008) (ix) Provision at 52.212-2, Evaluation -- Commercial Items, applies to this requirement. Site Visit: No site visit Submission of Quotes: (1) Quotes shall be received on or before the date and time specified in Section (xv) of this solicitation. Note: Offers received after the due date and time shall not be considered. (2) Offerors shall submit their quotes electronically via email to Sign up to see this detail. (3) Questions: Questions shall be submitted to the Contracting Officer in writing via e-mail. Oral questions are not acceptable due to the possibility of misunderstanding or misinterpretation. The cut-off date and time for receipt of questions is February 23 2026 by 12:00 PM EST. Questions received after this date and time may not be answered. Questions shall be answered in a formal amendment to the solicitation so all interested parties can see the answers. (4) Quote Format: The submission should be clearly indexed and logically assembled in order of the evaluation criteria below. All pages of the quote shall be appropriately numbered and identified by the complete company name, date and solicitation number in the header and/or footer. Evaluation Process: Award shall be made to the best value, as determined to be the most beneficial to the Government. Please read each section below carefully for the submittals and information required as part of the evaluation. Failure to provide the requested information below shall be considered non-compliant and your quote could be removed from the evaluation process. Offeror quotes shall be evaluated under FAR Part 13.106-2(b) -- Evaluation of Quotations or Offers. Therefore, the Government is not obligated to determine a competitive range, conduct discussions with all contractors, solicit final revised quotes, and use other techniques associated with FAR Part 15. The Government shall award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation shall be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers:  Price (Follow these instructions): Offeror shall complete Attachment 1 - Price Schedule, with offerors proposed contract line item prices inserted in appropriate spaces.  Past Performance: Offeror shall utilize Attachment 2 Past Performance Worksheet to provide at least one (1) but no more than (3) references of work, similar in scope and size with the requirement detailed in the (Performance Work Statement). References may be checked by the Contracting Officer to ensure your company is capable of performing the Statement of Work.  The Government also reserves the right to obtain information for use in the evaluation of past performance from any and all sources. Technical: The offeror s quote shall be evaluated to determine if the organization has the experience and capabilities to provide the requested services IAW the (Performance Work Statement) in a timely efficient manner.  Contractor shall demonstrate their corporate experience and approach to meet all requirements stated in the (Performance Work Statement). Contractor shall demonstrate that their technicians meet the qualification standards stated in the (Performance Work Statement). If you are planning to sub-contract some or all of this work, please provide the name and address(s) of all subcontractor(s) (if applicable) and a description of their planned subcontracting effort. SAM: Interested parties shall be registered in System for Award Management (SAM) as prescribed in FAR Clause 52.232-33. SAM information can be obtained by accessing the internet at www.sam.gov or by calling Sign up to see this detail. Interested parties not registered in SAM in sufficient time to meet the VA s requirement will be ineligible to receive a government contract. This determination will be at the discretion of the Contracting Officer. VISTA: The VA utilizes VISTA to issue a purchase order and liquidate invoices. Failure to register in VISTA may result in exclusion from the issuance of a VA contract. This determination will be at the discretion of the Contracting Officer. Interested parties with no prior VA contracts can request a Form 10091 at any time. (x) Please include a completed copy of the provision at 52.212-3, Offeror Representations and Certifications -- Commercial Items, with your offer via the SAM.gov website or a written copy. (xi) Clause 52.212-4, Contract Terms and Conditions -- Commercial Items (OCT 2018), applies to this acquisition in addition to the following addenda s to the clause: 52.204-16 Commercial and Government Entity Code Maintenance (JUL 2016); 52.219-6 Notice of Total Small Business Set-Aside; 52.232-40 Providing Accelerated Payments to Small Business Subcontractors (DEC 2013); 852.203-70 Commercial Advertising (MAY 2008); 852.232-72 Electronic Submission of Payment Requests (NOV 2018) Subcontracting Commitments - Monitoring and Compliance This solicitation includes VAAR 852.215-70, Service-Disabled Veteran-Owned and Veteran-Owned Small Business Evaluation Factors, and VAAR 852.215-71, Evaluation Factor Commitments. Accordingly, any contract resulting from this solicitation will include these clauses. The contractor is advised in performing contract administration functions, the CO may use the services of a support contractor(s) to assist in assessing contractor compliance with the subcontracting commitments incorporated into the Information Protection and Non-Disclosure and Disclosure of Conflicts of Interest Agreement to ensure the contractor's business records or other proprietary data reviewed or obtained in the course of assisting the CO in assessing the contractor for compliance are protected to ensure information or data is not improperly disclosed or other impropriety occurs. Furthermore, if VA determines any services the support contractor(s) will perform in assessing compliance are advisory and assistance services as defined in FAR 2.101, Definitions, the support contractor(s) must also enter into an agreement with the contractor to protect proprietary information as required by FAR 9.505-4, Obtaining access to proprietary information, paragraph (b). The contractor is required to cooperate fully and make available any records as may be required to enable the CO to assess the contractor compliance with the subcontracting commitments. (xii) Clause at 52.212-5, Contract Terms and Conditions Required To Implement Statutes Or Executive Orders -- Commercial Items, applies to this acquisition and in addition to the following FAR clauses cited, which are also applicable to the acquisition: 52.204-10, 52.209-6, 52.219-6, 52.219-28, 52.222-3, 52.222-21, 52.222-26, 52.222-36, 52.222-50, 52.223-18, 52.232-33, 52.222-41, 52.222-43 (Wage Determination Applicable (Manchester 2015-4019 Rev 23 posted on beta.sam.gov) (xiii) All contract requirement(s) and/or terms and conditions are stated above. (xiv) The Defense Priorities and Allocations System (DPAS) and assigned rating are not applicable to this requirement. (xv) RFQ responses are due Febraury 25 2026 by 10:00 AM EST. RFQ responses must be submitted via email to: Sign up to see this detail. Hand deliveries shall not be accepted. (xvi) The POC of this solicitation is Sign up to see this detail)











ATTACHMENT 1 PRICE SCHEDULE ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT Base Steam Coil Replacement 1.00 JB __________________ __________________




GRAND TOTAL __________________









ATTACHMENT 2 PAST PERFORMANCE WORKSHEET 1. Name of Contracting Activity, Government Agency, Commercial Firm or other Organization: 2. Contracting Activity Address: 3. Contract Number: 4. Date of Contract Award: 5. Beginning Date of Contract: 6. Completion Date of Contract: 7. Contract Value: 8. Type of Contract: 9a. Technical Point of Contact: 9b. Contracting Point of Contact: Name: Name: Title: Title: Address: Address: Telephone: Telephone: Email: Email: 10. Place of Performance: 11. Description of Work (Use a continuation sheet if necessary): 12. List any commendations or awards received: 13. List of Major Subcontractors:
ATTACHMENT 3 STATEMENT OF WORK CENTER FOR LONGTERM CARE OR STEAM COIL REPLACEMENT
VA CONNECTICUT HEALTHCARE SYSTEM (VACHS) VA MEDICAL CENTER WEST HAVEN 950 CAMPBELL AVENUE WEST HAVEN, CT 06516
BACKGROUND VA Connecticut Healthcare System requires the replacement of one steam coil in AHU 3 located in Building 1 Mechanical Room 4254 serving the Operating Room Suite.
JUSTIFICATION Air Handling equipment serving the operating room suite has experienced a split coil and requires immediate replacement to maintain temperature and humidity requirements within the Operating Room, Sterile Storage, and support spaces.
PLACE OF PERFORMANCE The Place of performance for this contract is VA Connecticut Healthcare System, West Haven VA Medical Center located at 950 Campbell Avenue, West Haven, CT 06516.
PERIOD OF PERFORMANCE The Contract Time Period of Performance will be 90 calendar days from Notice to Proceed (NTP) and includes service provider closeout.
QUALIFICATIONS To be considered eligible for consideration, potential bidders shall have a field service representative located within 200 miles of the West Haven Campus of the VA Connecticut Healthcare System and have been trained by the Original Equipment Manufacturer (OEM) on the specific model of equipment that he/she is being asked to provide services for.
The Contracting Officer and/or Contracting Officer s Representative (COR) specifically reserve the right to reject any of the Service Provider s personnel and refuse them permission to work on the equipment outlined herein, based upon credentials provided.
Bidders shall be evaluated on past performance, technical capability, financial capability, and ability to expedite lead time of manufacturing, shipping, and installation of steam coil timeline.
Bid breakdown shall include cost line item for expedited manufacturing and shipping and proposed schedule of installation. Local isolation will be supported by Facilities Management Service to ensure coordination with an expedited and anticipated installation of equipment. Bidders shall perform a mandatory pre-bid walkthrough at 8:30 a.m. on February 02, 2026, at VA Medical Center West Haven located at 950 Campbell Avenue, West Haven, CT 06516. Meet at Building 15 and obtain a temporary badge and complete a sign-in sheet.
SCOPE OF WORK The Service Provider shall furnish all labor, materials, equipment, tools, supervision, disposal, and all incidentals to complete work for the services described in this document. The service provider shall receive and work with the VA COR and designated POC.
Work shall occur during regular business hours Monday Friday 8:00 a.m. 4:40 p.m. and as coordinated. No work shall be performed on Government Holidays unless an emergency status has been indicated by the Contracting Officer.
US Federal Holidays:
New Year s Day Martin Luther King Jr. Day President s Day Memorial Day Juneteenth
Independence Day Labor Day Columbus Veterans Day Thanksgiving Day Christmas Day VA Connecticut Healthcare System West Haven Boiler #3 Inspection and Repairs Page 2 of 2
Description of Services: The project will include but not be limited to the following:
Service provider shall schedule and coordinate all work with the VA COR, Utilities Supervisor, and Chief Maintenance & Operations.
All LOTO request and procedures shall be in compliance with the VA Connecticut Healthcare System Medical Center Policy 138-075.
Coordinate all placement and removal of Lock Out Tag Out devices for any energy source with the VA COR/Maintenance & Operations.
Obtain hot work permit through VACHS Safety Office as required.
Protect all equipment in place during replacement activities.
Service provider shall replace steam coil in Trane AHU Model MCCB025UA0D0UB with Serial Number K08C35068: Turn of ABB drive (1AH3-1-SF3) and place lock on drive.
Close supply ball valve above the unit and place a lock.
Close supply gate valve located under the ductwork by the unfired boiler. Place chain and lock.
Close two condensate return valves located in front of the unit by the coil door and place locks.
Close actuator on Metasys energy management system.
Verify no voltage then disconnect all electrical connections in front of the panel of the coil.
Loosen unions and remove all obstructive piping from the front of the panel of the coil; actuators and steam piping.
Remove old coil and furnish new face end bypass coil.
Replace piping and tighten unions. Furnish any additional associated piping and fittings as required to complete this work.
Furnish and install new piping insulation as required.
Reconnect all electrical wiring and put panel back in place.
Open actuator on Metasys energy management system.
Remove all locks and open the two supply valves.
Remove all locks and open the two return valves.
Remove lock from and turn on ABB drive (1AH3-1-SF3).
Check for leaks and perform start up of system to confirm operation.
Replace associated piping insulation and incidentals required to perform this work.
Coordinate with VA COR, FMS Operations & Maintenance Supervisor for Johnson Controls, Inc. support to disconnect and reconnect controls. The cost to perform disconnect and reconnection of controls is not included in this contract.
Service provider shall perform start up and acceptance testing. Facilities Management Service shall designate a staff member to witness acceptance testing of all piping, pumps, and completed work upon completion.
Service provider shall clean up work area and all debris.
SUBMITTALS/DELIVERABLES: Service provider shall furnish all submittal item documentation with final dispositions and final documentation report with all tests, photos, and work completed within 10 business days following completion of work.
Minimum warranty of one year on all parts, labor, workmanship, and equipment shall be furnished.
SPECIAL INSTRUCTIONS All service provider personnel, sub-service providers and representatives visiting VA sites will be required to sign in upon arrival at Building 15 and/or retain a temporary VA badge. Each visiting individual be required to enter their name, their company s name, VA project title, reason for visit, and the times of arrival and departure. Arrangements for after normal hour working site visits must be made in advance and during normal working hours.
General: The Contracting Officer reserves the right to terminate any services, without payment for services completed, if such services are not needed or are not being adequately completed.
Approved Plans and Permits: Prior to the start of work, submit to VA copies of all required permits.
Site Visits: Day to day project administration will be performed by the COR. Periodic reviews, tests, and other field observation by the Government are not to be interpreted as superintendence nor as resulting in any approval of the service provider s apparent progress toward meeting the Government s objectives; but are intended to discover any information that the Contracting Officer may be able to call to the service provider s attention to prevent costly misdirection of effort.
The service provider shall remain responsible for constructing, operating, and maintaining the site in full accordance if the requirements of this solicitation. The service provider shall provide VA with a copy of all inspection reports for inspections conducted by local, regional, and state code authorities from the start of construction through issuance of the certificate of occupancy or completion.
The service provider shall develop and provide to the VA the following: Safety Plan: The service provider shall produce work in accordance with the latest editions of all applicable DVA guidelines (e.g. Construction Standards, Master Specifications, Standard Details, Special Design Criteria to meet Hospital Joint Commission (JCAHO) requirements), NFPA, Federal and State codes pertinent to the project scope.
All applicable personnel on site are required to obtain an Occupational Safety and Health Administration (OSHA) 10 hour construction certification, and the site competent person for the service provider must obtain an OSHA 30 hour construction certification.
Per VA Directive 1805, smoking vaping, and smokeless tobacco are prohibited on the grounds of VA facilities, including in vehicles. This Directive applies to all Service providers and their employees.
No photography of VA premises is allowed without written permission of the contracting officer. Patients and staff are not to be photographed at any time.
Prior to commencing work onsite, all Service providers and provider personnel shall furnish proof of receipt of required Tuberculosis testing in compliance with VHA Directive 1131(5), dated June 04, 2021.
Parking for Service provider and its employees shall be in designated areas only. Service provider to coordinate with COR.
The Service provider shall confine all operations (including storage of materials) on government premises to areas authorized or approved by the VA Contracting Officer. The Service provider shall hold and save the government, its officers, and agents, free and harmless from liability of any nature occasioned by the Service provider s performance. Working space and space available for storing materials shall be as determined by the COR. Workers are subject to the rules of the Medical Center applicable to their conduct. Execute work in such a manner as to reduce impacts with work being done by others.
Billing: Provide COR with a report or statement of work completed and include statements with request for payment. Statement should include service completed and the date each service item was completed. Labor charges shall be billed hourly, and any unused labor totals will be credited back to the VA Medical Center on the next billing cycle, upon receipt of the service report.
Safety Codes / Certification / Licensing: Environmental abatement work, if necessary, is to be performed by Service provider under supervision and monitoring for the VA by a Certified Industrial Hygienist.
The Service provider shall comply with all codes as described above, as well as codes customarily applied in VA construction jobs such as NFPA fire code, OSHA, VA Design Guides, etc. Labs used by the service provider shall be licensed as required by any applicable governing agencies, and their certifications and licenses shall be included in the reports.
Travel: Service provider and/or subservice providers will travel from their place of business to the West Haven VAMC of the VA Connecticut Healthcare System.
NARA Records Management Requirements
The following standard items relate to records generated in executing this contract:
Citations to pertinent laws, codes and regulations such as 44 U.S.C. Chapter 21, 29, 31, and 33; Freedom of Information Act (5 U.S.C. 552); Privacy Act (5 U.S.C. 552a); 36 CFR Part 1222 and Part 1228.
Contractor shall treat all deliverables under the contract as the property of the U.S. Government for which the Government Agency shall have unlimited rights to use, dispose of, or disclose such data contained therein as it determines to be in the public interest.
Contractor shall not create or maintain any records that are not specifically tied to or authorized by the contract using Government IT equipment and/or Government records.
Contractor shall not retain, use, sell, or disseminate copies of any deliverable that contains information covered by the Privacy Act of 1974 or that which is generally protected by the Freedom of Information Act.
The Contractor shall not create or maintain any records containing any Government Agency records that are not specifically tied to or authorized by the contract.
The Government Agency owns the rights to all data/records produced as part of this contract.
The Government Agency owns the rights to all electronic information (electronic data, electronic information systems, electronic databases, etc.) and all supporting documentation created as part of this contract. The Contractor must deliver sufficient technical documentation with all data deliverables to permit the agency to use the data.
The Contractor agrees to comply with Federal and Agency records management policies, including those policies associated with the safeguarding of records covered by the Privacy Act of 1974. These policies include the preservation of all records created or received regardless of format [paper, electronic, etc.] or mode of transmission [e-mail, fax, etc.] or state of completion [draft, final, etc.].
No disposition of documents will be allowed without the prior written consent of the Contracting Officer. The Agency and its contractors are responsible for preventing the alienation or unauthorized destruction of records, including all forms of mutilation. Willful and unlawful destruction, damage, or alienation of Federal records is subject to the fines and penalties imposed by 18 U.S.C. 2701. Records may not be removed from the legal custody of the Agency or destroyed without regard to the provisions of the agency records schedules.
The Contractor is required to obtain the Contracting Officer s approval prior to engaging in any contractual relationship (sub-contractor) in support of this contract requiring the disclosure of information, documentary material and/or records generated under or relating to this contract. The Contractor (and any sub-contractor) is required to abide by Government and Agency guidance for protecting sensitive and proprietary information.

More opportunities from Department Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)

Same awarding agency

NAICS: 811310
New
Federal
J061--Eaton Powerware System Replacement
Solicitation # 36C24127Q0030
The Department of Veterans Affairs, Network Contracting Office 1, is soliciting the in-kind replacement and ongoing maintenance of an end-of-life Eaton Powerware 9390-80 Model 80 UPS system at the Manchester VA Medical Center in New Hampshire. The project involves installing a newer model Eaton alternative, such as the Eaton 93PM or an equivalent system, that meets specific performance requirements, including a 60-minute battery run time and the ability to maintain power to the computer room via a maintenance bypass during servicing. The contract structure includes a base year from January 4, 2027, to January 3, 2028, with four subsequent 12-month option years. This procurement is a Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside. The scope of work encompasses the replacement of the UPS and extended battery cabinet, as well as quarterly and annual preventive maintenance, standby labor, and emergency services. Due to the criticality of the equipment, technicians performing preventive maintenance must be individually factory-certified or authorized by Eaton. The government will award the contract to the responsible offeror whose proposal is most advantageous based on a combination of price, technical quality, and past performance.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

3 days ago

DEADLINE

in 4 days
View Details
NAICS: 532490
New
Federal
W065--medical-grade oxygen cylinders/tanks
Solicitation # 36C24127Q0091
The Department of Veterans Affairs, Networking Contracting Office (NCO 01), intends to enter into a sole source procurement with Airgas USA, LLC, under FAR 6.302-1, to provide medical-grade compressed gas cylinders and tanks for the Boston VA Healthcare System. The requirement covers the delivery and maintenance of aluminum E cylinders with integrated regulators, MRI-safe cylinders, and steel H cylinders using the Diameter Index Safety System (DISS) across three locations: the West Roxbury, Jamaica Plain, and Brockton VA Medical Centers. The period of performance includes a base year from January 1, 2027, to December 31, 2027, and one option year extending through December 31, 2028. The contractor is required to make deliveries every Monday and Thursday to all three campuses, with a mandate to respond to emergency calls within two hours and non-emergency calls within 24 hours. Technical specifications require lightweight cylinders with integrated regulators capable of specific flow rates and a 50 psi outlet port, as well as rupture disk relief valves and single-valve configurations to mitigate safety risks. Airgas USA, LLC is identified as the sole source because they own the proprietary station tanks currently installed at the facilities; replacing these systems would be cost-prohibitive and cause significant clinical disruptions. Invoicing must be submitted per delivery and validated by the Contracting Officer's Representative for payment.
Other Commercial and Industrial Machinery and Equipment Rental and Leasing

POSTED

3 days ago

DEADLINE

in 3 days
View Details
NAICS: 541330
New
Federal
C1AZ--FY27 NRM 631-21-011 Build Elevator Tower for Building 25
Solicitation # 36C24126Q0518
Solicitation 36C24126Q0518 is a Small Business Set Aside for professional architectural and engineering (A/E) services to design and install a new elevator tower at Building 25 of the Edward P. Boland VAMC in Leeds, Massachusetts. The scope of work is divided into two parts: Part One covers the design phase, and Part Two covers optional construction period services. The estimated magnitude of the resulting construction is between $2,000,000 and $5,000,000, with an estimated construction performance period of 545 calendar days. Key technical requirements include the validation of conceptual designs, the design of an elevator pit sump pump with an oil interceptor, and strict adherence to NFPA, ABAAS, and VA Design Manuals. Interested firms must submit an SF 330 package by December 7, 2026, limited to 65 pages, though CPARS and PPQs are exempt from this limit. A critical qualification requirement is that firms must demonstrate a minimum of two comprehensive exterior historical renovation projects completed specifically within the Commonwealth of Massachusetts to ensure familiarity with state-specific regulatory and preservation procedures. Firms that assisted with the conceptual design are not precluded from bidding. The selection process emphasizes specific experience, and the A/E is required to maintain a rigorous quality assurance program, including a QC tracker and written certifications for each submission.
Engineering Services

POSTED

7 days ago

DEADLINE

in 11 days
View Details

Get AI-powered intelligence on the opportunities still open

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS