Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on March 14, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

4540-- EMS Trash Compactor Repair & Maintenance - Pittsburgh VAMC

Closed
36C24424Q0502Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
The Earle C. Clements Job Corps Center, operated by Management & Training Corporation, is soliciting a lump sum fee-for-service contract for the comprehensive clutch replacement of a Kubota M8200 tractor located in Morganfield, Kentucky. The scope of work requires the contractor to provide all labor, materials, tools, and transportation to disassemble the tractor, inspect and replace the clutch friction discs, plates, bearings, oil seals, and O-rings, and resurface the flywheel. Additionally, the contractor must replace necessary hydraulic pipes, flanges, and oil filters, verify PTO clutch operation, and perform final testing to ensure the unit is safe and fully operational according to manufacturer specifications and industry practices. This solicitation is open to various small business categories, including VOSB, SDVOSB, WOSB, and HUBZone certified entities, with a response deadline of November 3, 2026. Award will be based on best value. Applicants must provide a Unique Entity ID, Tax ID, and DUNS number via the MTC Supplier Self-Certification form. The contract incorporates several federal regulations, including FAR 52.222-4 regarding overtime compensation, FAR 52.222-50 regarding trafficking in persons, and FAR 52.209-6 for subcontractor debarment disclosure for amounts exceeding 45,000 dollars. Contractors are also required to provide proof of insurance and adhere to strict security and confidentiality protocols regarding non-public information.
Earle C. Clements Job Corps Center

POSTED

about 8 hours ago

DEADLINE

in 13 days

General Info

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

Department of Veterans Affairs University Drive Campus North Loading Dock Brackenridge Street and University Drive, Pittsburgh, PA 15240, PA

Set-Aside

NONE

Documents

1

EMS Trash Compactor Repair & Maintenance - Pittsburgh VAMC

DOCX, High priority: read this firstrfi
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)
Contacts1 person available
OfficePITTSBURGH, PA, 15215, USA
Office AddressPITTSBURGH, PA, 15215, USA
Contacts
Derrick L. MaruskiContract Specialist

Full Description

Show more
Sources Sought Notice Sources Sought Notice Page 9 of 9 *= Required Field Sources Sought Notice Page 1 of 9 DESCRIPTION THIS IS NOT A SOLICITATION ANNOUNCEMENT. THIS IS A REQUEST FOR INFORMATION ONLY. This Request for Information (RFI) is intended for information and planning purposes only at this time and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. Because this is a Request for Information announcement, no evaluation letters and/or results will be issued to the respondents. No solicitation exists. Therefore, do not request a copy of a solicitation. The Pittsburgh VA Medical Center requires Repair & Maintenance of EMS Trash Compactor. 1. Purpose: The purpose of this state of work is to address commercial grade trash compactor preventative maintenance and repair and serve as a statement of work. The hospital waste management industry general goals and objectives are recycling, reuse, and repurposing. This compactor was found in good condition despite the rust, dents, bent front end rollers, maintenance needs, and all else suggests the machine has another 10 or more years of continued service. To meet VHA waste management goals and objectives, EMS Management believe repair reuse and repurposing is best choice in meeting national goals and objectives relative to the trash compactors. 2. Location: University Drive Campus, North Loading Dock, Brackenridge Street and University Drive. Compactor Details: Marathon Self Contained, Model RJ-250-SC, Serial Number 51554537, manufactured November 22, 2017. The trash compactor identifying features: a self-contained 30 cubic yard trash compactor with enclosed box or industry terminology enclosed doghouse , dump hatches on left and right side (side loading), compactor is beige-tan color, black-yellow lettered-painted sign stating trash only featured on front end of the trash compactor. 3. Scope of Work (Service Delivery): A heavily utilized machine, this commercial grade trash compactor preventative maintenance and repairs. Below is list of preventative maintenance and repair needs: Front end repair includes repair of roller frames and replacement of front left and right-side rollers. Rear end left and right rollers replacement/repair. Front end maintenance cover replacement of the bent metal, repaint tan-beige color, new fasteners. New fasteners for top maintenance hatch cover All left and right rear end safety mechanism preventative maintenance. The rear hatch safety catch on the left rear side of the machine is frozen and needs preventative maintenance. To fully engage. Grease fitting and preventative maintenance greasing of compactor ram mechanism Adjustment, replacement of left and right-side doghouse door hatch safety switches, adjustment, and preventative maintenance hinges-grease fittings. The safety switch repair and replacement location are upper right and left interior side of hatch doors. Deck and channeling installation. Removal of old worn-out channeling and guides and installation of new deck and channeling. Rear dump hatch preventative maintenance replacement of rear hatch gasket Hydraulic system, preventative maintenance of compactor motoring, ram motoring, new hydraulic oil, reattach the motoring hood cover atop the motoring, fasteners installed, cleaning interior motoring compartments of ram motoring and moving parts, grease and lube moving parts, preventative maintenance. Refasten the hydraulic hose to prevent premature wear and tear due to contact with concrete deck. Exterior painting of compactor from front to back, top, beige-tan color. This includes taking the machine off site to proper cleaning and painting contractor site within the Pittsburgh Metropolitan Region. New safety sticker package and affixing new safety sticker to machine. Return of machine, diagnostic to ensure the machine is fully functional. Preventative maintenance responsibilities include cleaning exterior and interior of the compactor cargo to ram unit, inspection, greasing, hydraulic oil replacement, filter replacement, bleeding any water or moisture, recycling, and proper disposal of old or expended hydraulic oil and materials, spill containment. Check and calibration of compactor. Special considerations: To and from job site hauling machine, the contractor is responsible for hauling the machine to and from jobs site. VAPHS understanding is that the repair and preventative maintenance requires the trash compactor to hauled from the VAPHS University Drive to contractor repair shop for example repair of front end and painting. On site repairs and welding requires a VAPHS permit in advance from our Safety and Facilities Management Department. On site repair, the contractor is expected to work with Facilities Management Service Electricians to shut off and turn on and lock out tag out procedures once the repair has commenced. On site preventative maintenance, the contractor is expected to maintain job site safety and compliance and ecological compliance in event any kind of oil or grease is spilled or dripped. The compactor is serviced by contractor for collections. Coordination and scheduling the compactor repair and preventative maintenance requires working with contractor who hauls and empties the compactor and station staff. Contractor will need to be able to work with contractor who hauls our waste to coordinator a time frame when the machine is empty. 4. Repair and Preventative Maintenance Time Frame: VAPHS EMS believes this repair and preventative maintenance can be achieved in two days (48 hours). Important, this trash compactor is used daily hourly. VAPHS requires the repair and preventative maintenance to be completed no greater than five days or less. The following is believed to be reasonable achievement time frame: Scheduling and pick up. Monday to Friday off site and on-site work is completed. Weekend is included. (Saturday & Sunday) Provides five business days. Planning and scheduling should consider government holidays. To avoid delay, it is essential the contractor thoroughly evaluate the machine for repair and preventative maintenance, have the parts, shop tools, shop space and capability to complete the work in short four day turnaround time frame. It is important to note, most of the preventative maintenance and repair can be achieved on VAPHS site. Other repairs and preventative maintenance may require off site completed at a proper trash compactor repair facility. Scheduling & coordination must be preapproved with the VAPHS EMS contract officer representative. In event the repair is going beyond the five-day schedule, then it is expected the contractor performing the repair must provide equal or same compactor until repair is completed. During prior evaluation, the compactor was mechanical in proper fit and condition. However, the exterior mechanisms rollers, gaskets, exterior and other items listed needed preventative maintenance and repair/replacement. 5. Responsibilities: VAPHS is responsible for turning off and on the electric to the trash compactor. VAPHS EMS is responsible for scheduling the final trash collection and preventing staff from using the compactor all the while the contractor is expected to collect the compactor. Making certain the compactor is empty of any or most contaminates (trash). Contractor is responsible for scheduling, providing licensed, insured, bonded, and competent employees or sub-contractor to facilitate the hauling on and off site. Missing deadlines could lead to financial penalties, additional costs, and affecting vendor status. In the event the compactor repair goes beyond five days allotted in this contract. The contractor is expected to provide same or similar trash compactor until repair is completed no cost to VAPHS. In other words, a repair exceeding 120 hours requires the contractor to provide same or similar trash compactor until repair is completed no cost to the government. Completed repair is compactor on VAPHS site, tested, and validated as fully functional and achieving the specifications of the contract. Contractor is expected a written warranty of repair and preventative maintenance work and parts. Contractor is expected ISO compliance and industry standards for waste management equipment repair work. Responses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, DUNS Number, Cage Code, size of business pursuant to North American Industrial Classification System (NAICS) 811310 (size standard of $12.5 Million dollars). Please answer the following questions: Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)? Is your company considered small under the NAICS code identified under this RFI? Is the product you are providing information about manufactured in the United States? If not, please provide the country where the unit is manufactured. If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job. Does your company have an FSS contract with GSA or the NAC or are you a contract holder with any other federal contract? If so, please provide the contract number. If you are an FSS GSA/NAC contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract? General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. Please submit your capabilities regarding the salient characteristics detailed above to establish capabilities for planning purposes. Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A. Please provide your UEI number. This RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 13. Telephone responses will not be accepted. Responses must be received via e-mail to Derrick.Maruski2@va.gov no later than, 9:00 AM Eastern Standard Time (EST) on 03/22/2024. This notice will help the VA in determining available potential sources only. Do not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action. All questions will be addressed by the Contracting Specialist, Derrick L. Maruski. All firms responding to this Request for Information are advised that their response is not a request for proposal, therefore will not be considered for a contract award. If a solicitation is issued, information will be posted on the Contract Opportunities website for all qualified interested parties at a later date and interested parties must respond to the solicitation to be considered for award. This notice does not commit the government to contract for any supplies or services. The government will not pay for any information or administrative cost incurred in response to this Request for Information. Information will only be accepted in writing by e-mail to Contracting Specialist, Derrick L. Maruski at Derrick.Maruski2@va.gov. DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

More opportunities from Department Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)

Same awarding agency

NAICS: 236220
New
Federal
Z1DA-- 460-26-004 | Wilmington VAMC Roof Replacement | NCO 4 Construction East (VA-26-00029152)
Solicitation # 36C24426B0015
Solicitation 36C24426B0015 is a sealed bid invitation for a firm-fixed price contract to perform roof replacement services at the Wilmington VA Medical Center in Delaware. The project involves the removal and replacement of Roof 3D, the Physical Therapy Roof, Roof 10, and Roof 11. The scope of work includes the installation of 60 Mil Elevate RubberGard EPDM LS-FR white roofing material or an equivalent, flat tapered insulation, and HD cover board, as well as the inspection and replacement of deteriorated metal decking. All installations must meet high wind zone design requirements and include a minimum 20-year warranty against leaks. The estimated construction magnitude is between $250,000 and $500,000. This procurement is a 100% set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB). To be eligible for award, bidders must be registered in the System for Award Management (SAM), VETCERT, and the VETS-4212 database. Award will be granted to the responsive and responsible bidder offering the lowest price. Key requirements include compliance with Davis-Bacon wage determinations for New Castle County, Delaware, and strict adherence to OSHA safety standards, requiring a 30-hour certified competent person on-site. Performance and payment bonds are required for contracts exceeding $150,000. The final bid opening is scheduled for November 4, 2026, at 11:00 AM EST.
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in 14 days
View Details
NAICS: 334516
New
Federal
6550--VISN 4 Coagulation Testing
Solicitation # 36C24427Q022
The Department of Veterans Affairs, Network Contracting Office 4, is soliciting an indefinite-quantity contract for advanced coagulation testing and monitoring services to support nine VA Medical Centers. The scope of work includes the delivery, installation, and removal of a self-contained coagulation testing system capable of performing Prothrombin Time, Activated Partial Thromboplastin Time, International Normalized Ratio, International Sensitivity Index, Fibrinogen, D-Dimer, and Anti-Factor Xa tests. The period of performance is established from December 1, 2026, through November 30, 2031. Technical requirements specify a bi-directional, bar-coded computer interface compatible with the VA laboratory information system and Beckman Coulter Remisol software, with a barcode reading failure rate of less than 1%. The contractor must adhere to CLSI standards for quality control and comply with OSHA, EPA, and 40 CFR regulations regarding hazardous waste documentation and safety data sheets. Equipment acceptance is contingent upon meeting performance standards for 30 consecutive calendar days at an effectiveness level of 90% or more. Award will be based on a comparative evaluation of past performance, price, and technical capability to determine the most advantageous offer to the government. The solicitation is open to all qualified offerors, with a specific price evaluation preference for HUBZone small business concerns. Submissions must include a price quotation and past performance information, with an optional technical section, and be delivered electronically to the contracting officer.
Analytical Laboratory Instrument Manufacturing

POSTED

2 days ago

DEADLINE

in 5 days
View Details
NAICS: 236220
New
Federal
Z1DA--NRM| 460-26-007 Electrical Distribution Inspection Repairs | NCO 4 Construction East (VA-26-00057558)
Solicitation # 36C24427B0002
The Department of Veterans Affairs Network Contracting Office 4 has issued a Request for Information for planning and market research purposes regarding electrical distribution inspection repairs at the Wilmington, Delaware VA Medical Center. This is not a request for proposal, and the government is not obligated to award a contract based on this notice. The project involves repairing all failures identified in the facility's electrical inspection and testing report, specifically focusing on the review and validation of results, the procurement and installation of circuit breakers and racking mechanisms, and the repair of old equipment to be used as future spares. All work must adhere to VA requirements, NETA test standards, and applicable federal, state, and local codes, with a total performance period of 365 days from the Notice to Proceed. The estimated magnitude of construction is between 25,000.00 and 100,000.00. This opportunity is designated as a set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 236220 for Commercial and Institutional Building Construction. Interested contractors must submit a statement of interest, capability statement, pricing for similar past projects, and company identification details, including their UEI number and intended contracting role, to the designated point of contact by October 30, 2026, at 4:00 PM EST. Submissions must be electronic, as hard copies will not be accepted.
Commercial and Institutional Building Construction

POSTED

5 days ago

DEADLINE

in 9 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS