Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Veterans Affairs was posted on August 4, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--Consignment Agreement - BARD Peripheral Vascular Detroit VAMC

Closed
36C25025Q0811Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

OH

Set-Aside

NONE

Documents

1

Consignment Agreement - BARD Peripheral Vascular Detroit VAMC (36C25025Q0811)

DOCX, High priority: read this first9 pages · rfq
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

special-notice

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)
Contacts1 person available
OfficeDAYTON, OH, 45428, USA
Office AddressDAYTON, OH, 45428, USA
Contacts
LouAnn GillilandContract Specialist

Full Description

Show more
The Department of Veterans Affairs, VHA Regional Procurement Office Central, Network Contracting Office 10, located at 3140 Governor s Place Blvd., Suite 210, Kettering, OH 45409 intends to award a sole source, firm-fixed-price consignment agreement to Bard Peripheral Vascular, Inc., 1625 West 3rd Street, Tempe, AZ 85281, Phone: +1 (555) 000-0000. It is the Government's intention to solicit and negotiate with only this source. The procurement will be in accordance with Federal Acquisition Regulation (FAR) Part 13.5, Simplified Procedures for Certain Commercial Items, specifically FAR 13.501 Special Documentation Requirements, where acquisitions conducted under Simplified Acquisition Procedures are exempt from the requirements of FAR Part 6, but still require a justification using the format of FAR 6.303-2. The authority for applying the Simplified Procedures for Commercial Items of FAR 13.5 is 41 U.S.C. 1901 and is implemented by for restricting competition on this procurement via FAR 13.106-1(b)(2). It is the Government s belief that the proposed candidate is the sole manufacturer capable of meeting the requirement. The associated North America Classification Systems (NAICS) Code is 339113 and the Small Business Size Standard is 800 employees. Anticipated period of performance will include a 12-month base period and four 12-month option periods. The procurement will be awarded as a new requirement. Description of requirements: PART NUMBER DESCRIPTION PAR LEVEL PERIPHERAL LUTONIX DCB LX181304604F BALLOON,LUTONIX 018,4MMX60MMX130CM 1 LX1813041004F BALLOON,LUTONIX 018,4MMX100MMX130CM 1 LX3513041005F BALLOON,LUTONIX,4MMX100MMX130CM 1 LX351305605F BALLOON,LUTONIX,5MMX60MMX130CM 1 LX3513051005F BALLOON,LUTONIX,5MMX100MMX130CM 1 LX3513051505F BALLOON,LUTONIX,5MMX150MMX130CM 1 LX3513052205F BALLOON,LUTONIX,5MMX220MMX130CM 1 LX351306605F BALLOON,LUTONIX,6MMX60MMX130CM 1 LX3513061005F BALLOON,LUTONIX,6MMX100MMX130CM 1 LX3513061505F BALLOON,LUTONIX,6MMX150MMX130CM 1 LX3513062205F BALLOON,LUTONIX,6MMX220MMX130CM 1 ULTRAVERSE 035 130cm U3513044 CATH,ULTRA,035,4MM X 40MM X 130CM 2 U35130410 CATH,ULTRA,035,4MM X 100MM X 130CM 2 U3513054 CATH,ULTRA,035,5MM X 40MM X 130CM 2 U35130510 CATH,ULTRA,035,5MM X 100MM X 130CM 2 U35130515 CATH,ULTRA,035,5MMX 150MMX130CM 2 U35130520 CATH,ULTRA,035,5MMX 200MMX130CM 2 U3513064 CATH,ULTRA,035,6MM X 40MM X 130CM 2 U35130610 CATH,ULTRA,035,6MM X 100MM X 130CM 2 U35130615 CATH,ULTRA,035,6MMX 150MMX130CM 2 U35130620 CATH,ULTRA,035,6MM X 200CMX130CM 2 U3513074 CATH,ULTRA,035,7MM X 40MM X 130CM 2 U3513078 CATH,ULTRA,035,7MM X 80MM X 130CM 2 U3513084 CATH,ULTRA,035,8MM X40MM X 130CM 2 U3513088 CATH,ULTRA,035,8MM X 80MM X 130CM 2 U35130104 CATH,ULTRA,035,10MM X 40MM X 130CM 2 U35130108 CATH,ULTRA,035,10MM X 80MM X 130CM 2 ULTRAVERSE 035 75cm U357566 CATH,ULTRA,035, 6mm x 60mm x 75cm 2 U357568 CATH,ULTRA,035, 6mm x 80mm x 75cm 2 U357556 CATH,ULTRA,035, 5mm x 60mm x 75cm 2 U357558 CATH,ULTRA,035, 5mm x 80mm x 75cm 2 U357546 CATH,ULTRA,035, 4mm x 60mm x 75cm 2 U357548 CATH,ULTRA,035, 4mm x 80mm x 75cm 2 ULTRAVERSE 014 and 014 RX U4200210RX CATH,ULTRAVERSE RX,014,2MMX100MM 2 U42002H10RX CATH,ULTRAVERSE RX,014,2.5MMX100MM 2 U4200310RX CATH,ULTRAVERSE RX,014, 3MMX100MM 2 ULTRAVERSE 018 U87524 CATH,ULTRA 018 2mm x 40mm x 75cm 2 U87544 CATH,ULTRA 018 4mm x 40mm x 75cm 2 U8150315 CATH,ULTRA, .018,3MM X 15CM X 150CM 2 U8150322 CATH,ULTRA, .018,3MM X 22CM X 150CM 2 U815044 CATH,ULTRA, .018,4MM X 4CM X 150CM 2 U8150410 CATH,ULTRA, .018,4MM X 10CM X150CM 2 U815054 CATH,ULTRA, .018,5MM X 4CM X 150CM 2 U8150510 CATH,ULTRA, .018,5MM X 10CM X150CM 2 U8150515 CATH,ULTRA, .018,5MM X 15CM X 150CM 2 U8150522 CATH,ULTRA, .018,5MM X 22CM X 150CM 2 U815064 CATH,ULTRA, .018,6MM X 4CM X 130CM 2 U8150610 CATH,ULTRA, .018,6MM X 10CM X130CM 2 U8150622 CATH,ULTRA, .018,6MM X 22CM X 130CM 2 LifeStent 5F051203CS LifeStent 5FR 5mm x 120mm x 130cm 1 5F060803CS LifeStent 5FR 6mm x 80mm x 130cm 1 5F061203CS LifeStent 5FR 6mm x 120mm x 130cm 1 5F061503CS LifeStent 5FR 6mm x 150mm x 130cm 1 5F071203CS LifeStent 5FR 7mm x 120mm x 130cm 1 Grafts F8007TWSC 7mm x 80cm thin wall with flex beading 1 F8006TWSC 6mm x 80cm thin wall with flex beading 1 F5008TWSC 8mm x 50cm thin wall flex beading 1 DFX9006SC Distaflo Mini Cuff 1 DFM8006SC Distaflo Small Cuff 1 LifeStar Self Expanding Iliac VIUS08040 8mm x 40mm x 80cm 2 VIUS08060 8mm x 60mm x 80cm 2 LifeStream Balloon Expandable Covered Stent LSMU1350837 8mm x 38mm x 135cm 2 LSMU1350858 8mm x 58mm x 135cm 2 LSMU1351038 10mm x 38mm x 135cm 2 LSMU1351058 10mm x 58mm x 135cm 2 LUTONIX® 035 Drug Coated Balloon PTA Catheters LX3575460V Balloon Diameter 4/L-60/Cath L-75/Sheath Comp 5/Nominal Pressure 6/Rated Burst Pressure 12 2 LX3575540V Balloon Diameter 5/L-40/Cath L-75/Sheath Comp 5/Nominal Pressure 6/Rated Burst Pressure 12 2 LX3575560V Balloon Diameter 5/L-60/Cath L-75/Sheath Comp 6/Nominal Pressure 6/Rated Burst Pressure 12 2 LX35755100V Balloon Diameter 5/L-75/Cath L-75/Sheath Comp 5/Nominal Pressure 6/Rated Burst Pressure 12 2 LX3575640V Balloon Diameter 6/L-40/Cath L-75/Sheath Comp 5/Nominal Pressure 7/Rated Burst Pressure 12 2 LX3575660V Balloon Diameter 6/L-60/Cath L-35/Sheath Comp 5/Nominal Pressure 7/Rated Burst Pressure 12 2 LX3575680V Balloon Diameter 6/L-80/Cath L-75/Sheath Comp 5/Nominal Pressure 7/Rated Burst Pressure 7 2 LX35756100V Balloon Diameter 6/L-100/Cath L-75/Sheath Comp 5/Nominal Pressure 7/Rated Burst Pressure 12 2 LX3575740V Balloon Diameter 7/L-40/Cath L-75/Sheath Comp 5/Nominal Pressure 7/Rated Burst Pressure 12 2 LX3575760V Balloon Diameter 7/L-60/Cath L-75/Sheath Comp 5/nominal Pressure 7/Rated Burst Pressure 12 2 LX35757100V Balloon Diameter 7/L-100/Cath L-75/Sheath Comp 7/Nominal Pressure 6/Rated Burst Pressure 12 2 LX3575840V Balloon Diameter 8/L-40/Cath L-75/Sheath Comp 7/Nominal Pressure 6/Rated Burst Pressure 12 2 LX3575860V Balloon Diameter 8/L-60/Cath L-75/Sheath Comp 7/Nominal Pressure 6/Rated Burst Pressure 12 2 LX35758100V Balloon Diameter 8/L-100/Cath L-75/Sheath Comp 7/Nominal Pressure 6/Rated Burst Pressure 12 2 LX3575940V Balloon Diameter 9/L-40/Cath L-75/Sheath Comp 7/Nominal Pressure 6/Rated Burst Pressure 11 2 LX3575960V Balloon Diameter 9/L-60/Cath L-75/Sheath Comp 7/Nominal Pressure 6/Rated Burst Pressure 11 2 LX35751040V Balloon Diameter 10/L-40/Cath L-75/Sheath Comp 8/Nominal Pressure 6/Rated Burst Pressure 11 2 LX35751060V Balloon Diameter 10/L-60/Cath L-75/Sheath Comp 8/Nominal Pressure 6/Rated Burst Pressure 11 2 LX35751240V Balloon Diameter 12/L-40/Cath L-75/Sheath Comp 9/Nominal Pressure 6/Rated Burst Pressure 10 2 LX35751260V Balloon Diameter 12/l-60/Cath L-75/Sheath Comp 9/Nominal Pressure 6/Rated Burst Pressure 10 2 ATLAS® PTA Balloon Dilatation Catheters AT75144 Balloon Diameter 14/L-4/Cath L-75/Sheath Comp 7/Nominal Pressure 6/Rated Burst Pressure 18 2 AT75164 Balloon Diameter 16/L-4/Cath L-75/Sheath Comp 8/Nominal Pressure 6/Rated Burst Pressure 18 2 ATLAS® GOLD PTA Balloon Dilatation Catheters ATG80124 Balloon Diameter 12/L-4/Cath L-80/Sheath Comp 7/Nominal Pressure 6/Rated Burst 18 3 ATG80144 Balloon Diameter 14/L-4/Cath L-80/Sheath Comp 7/Nominal Pressure 6/Rated Burst 18 2 ATG80164 Balloon Diameter 16/L-4/Cath L-80/Sheath Comp 7/Nominal Pressure 6/Rated Burst 18 2 ATG80184 Balloon Diameter 18/L-4/Cath L-80/Sheath Comp 8/Nominal Pressure 6/Rated Burst 16 2 ATG80204 Balloon Diameter 20/L-4/Cath L-80/Sheath Comp 9/Nominal Pressure 6/Rated Burst 16 2 DORADO® PTA Balloon Dilatation Catheters DR8034 Balloon Diameter 3/L-4/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 2 DR80310 Balloon Diameter 3/L-10/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 2 DR8044 Balloon Diameter 4/L-4/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 2 DR80410 Balloon Diameter 4/L-10/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 2 DR8054 Balloon Diameter 5/L-4/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 2 DR8056 Balloon Diameter 5/L-6/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 3 DR80510 Balloon Diameter 5/L-10/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 2 DR8064 Balloon Diameter 6/L-4/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 4 DR8066 Balloon Diameter 6/L-6/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 2 DR8068 Balloon Diameter 6/L-8/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 3 DR8074 Balloon Diameter 7/L-4/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 22 4 DR8076 Balloon Diameter 7/L-6/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 22 4 DR8078 Balloon Diameter 7/L-8/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 22 3 DR8084 Balloon Diameter 8/L-4/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 22 4 DR8086 Balloon Diameter 8/L-6/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 22 4 DR8088 Balloon Diameter 8/L-8/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 22 4 DR80810 Balloon Diameter 8/L-10/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 22 3 DR8094 Balloon Diameter 9/L-4/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 20 4 DR8098 Balloon Diameter 9/L-8/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 20 3 DR80104 Balloon Diameter 10/L-4/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 20 4 DR80108 Balloon Diameter 10/L-8/Cath L-80/Sheath Comp 7/Nominal Pressure 8/Rated Burst 20 4 FLUENCY® Plus Endovascular Stent Grafts FEM06040 Stent Graft Diameter 6mm/L-40mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8F 1 FEM08080 Stent Graft Diameter 8mm/L-80mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 9F 1 FEM09060 Stent Graft Diameter 9mm/L-60mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 9F 1 FEM12040 Stent Graft Diameter 12mm/L-40mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 10F 1 FEM14040 Stent Graft Diameter 13.5mm/L-40mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 10F 1 FEM14060 Stent Graft Diameter 13.5mm/L-60mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 10F 1 DORADO® PTA Balloon Dilatation Catherers DR8034 Balloon Diameter 3/L-4/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 2 DR80310 Balloon Diameter 3/L-10/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 2 DR8044 Balloon Diameter 4/L-4/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 2 DR80410 Balloon Diameter 4/L-10/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 2 DR8054 Balloon Diameter 5/L-4/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 2 DR8056 Balloon Diameter 5/L-6/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 3 DR80510 Balloon Diameter 5/L-10/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 2 DR8064 Balloon Diameter 6/L-4/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 4 DR8066 Balloon Diameter 6/L-6/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 2 DR8068 Balloon Diameter 6/L-8/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 24 3 DR8074 Balloon Diameter 7/L-4/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 22 4 DR8076 Balloon Diameter 7/L-6/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 22 4 DR8078 Balloon Diameter 7/L-8/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 22 3 DR8084 Balloon Diameter 8/L-4/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 22 4 DR8086 Balloon Diameter 8/L-6/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 22 4 DR8088 Balloon Diameter 8/L-8/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 22 4 DR80810 Balloon Diameter 8/L-10/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 22 3 DR8094 Balloon Diameter 9/L-4/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 20 4 DR8098 Balloon Diameter 9/L-8/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 20 3 DR80104 Balloon Diameter 10/L-4/Cath L-80/Sheath Comp 6/Nominal Pressure 8/Rated Burst 20 4 DR80108 Balloon Diameter 10/L-8/Cath L-80/Sheath Comp 7/Nominal Pressure 8/Rated Burst 20 4 FLUENCY® Plus Endovascular Stent Grafts FEM06040 Stent Graft Diameter 6mm/L-40mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8F 1 FEM08080 Stent Graft Diameter 8mm/L-80mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 9F 1 FEM09060 Stent Graft Diameter 9mm/L-60mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 9F 1 FEM12040 Stent Graft Diameter 12mm/L-40mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 10F 1 FEM14040 Stent Graft Diameter 13.5mm/L-40mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 10F 1 FEM14060 Stent Graft Diameter 13.5mm/L-60mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 10F 1 FLUENCY Plus Endovascular Stent Grafts Covera Vascular Covered Stent AVFM06040 Stent Graft Diameter 6mm/L-40mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVFM06060 Stent Graft Diameter 6mm/L-60mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVFM06080 Stent Graft Diameter 6mm/L-80mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVFM06100 Stent Graft Diameter 6mm/L-100mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVFM07040 Stent Graft Diameter 7mm/L-40mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVFM07060 Stent Graft Diameter 7mm/L-60mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVFM08040 Stent Graft Diameter 8mm/L-40mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVFM08060 Stent Graft Diameter 8mm/L-60mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVFM08080 Stent Graft Diameter 8mm/L-80mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVFM08100 Stent Graft Diameter 8mm/L-100mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVFM09040 Stent Graft Diameter 9mm/L-40mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVFM09060 Stent Graft Diameter 9mm/L-60mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVFM09080 Stent Graft Diameter 9mm/L-80mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVFM09100 Stent Graft Diameter 9mm/L-100mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVFM10040 Stent Graft Diameter 10mm/L-40mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVFM10060 Stent Graft Diameter 10mm/L-60mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVFM10080 Stent Graft Diameter 10mm/L-80mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 2 AVFM10100 Stent Graft Diameter 10mm/L-100mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVSM06040 Stent Graft Diameter 6mm/L-40mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVSM06060 Stent Graft Diameter 6mm/L-60mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVSM06080 Stent Graft Diameter 6mm/L-80mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVSM07040 Stent Graft Diameter 7mm/L-40mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVSM07060 Stent Graft Diameter 7mm/L-60mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVSM07080 Stent Graft Diameter 7mm/L-80mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVSM08040 Stent Graft Diameter 8mm/L-40mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVSM08060 Stent Graft Diameter 8mm/L-60mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVSM08080 Stent Graft Diameter 8mm/L-80mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVSM09040 Stent Graft Diameter 9mm/L-40mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVSM09060 Stent Graft Diameter 9mm/L-60mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVSM09080 Stent Graft Diameter 9mm/L-80mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVSM10040 Stent Graft Diameter 10mm/L-40mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVSM10060 Stent Graft Diameter 10mm/L-60mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 AVSM10080 Stent Graft Diameter 10mm/L-80mm/Cath L- 80cm/Guidewire 0.035"/Cath Diam 8FR 1 FLUENCY Plus Endovascular Stent Grafts Covera Vascular Covered Stent Bard WavelinQ Endo Fistula WQ4300 WavelinQ Catheter 1 ESU-1 WavelinQ System 1 CZ-400-TVA WavelinQ Arm Board 1 Conquest 035 Drug Coated Balloon PTA Catheters CQ7564 Balloon Diameter 6mm/L-4cm/Cath L-75cm 2 CQ7566 (pending updated number) Balloon Diameter 6mm/L-6cm/Cath L-75cm 2 CQ7568 Balloon Diameter 6mm/L-8cm/Cath L-75cm 2 CQ7574 Balloon Diameter 7mm/L-4cm/Cath L-75cm 2 CQ7576 Balloon Diameter 7mm/L-6cm/Cath L-75cm 2 CQ7578 Balloon Diameter 7mm/L-8cm/Cath L-75cm 2 CQ7584 Balloon Diameter 8mm/L-4cm/Cath L-75cm 2 CQ7586 Balloon Diameter 8mm/L-6cm/Cath L-75cm 2 CQ7588 Balloon Diameter 8mm/L-8cm/Cath L-75cm 2 Presto Inflation Device ID4030 Sterile Disposable with 30cc barrel 5 This notice satisfies the requirement at FAR 5.201(b)(1), to publicize the proposed contract action. This notice of intent is not a request for competitive proposals. No solicitation documents are available at this time. Interested parties may give written notice to contact@example.gov by 12:00pm EST on August 8, 2025. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to meet the subject requirement. This information shall be provided at no cost or obligation to the Government. Responses will be considered by the Government; however, a determination by the Government not to compete the proposed acquisition based upon responses of this notice is solely within the discretion of the Government. Inquiries shall be emailed to contact@example.gov. No telephone requests will be accepted. Any response to this notice must show clear and convincing evidence that competition would be advantageous to the Government in future procurements.

More opportunities from Department Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)

Same awarding agency

NAICS: 562111
New
Federal
S205--General Waste & Recycling Removal Services - Detroit PoP 04/01/2032
Solicitation # 36C25027Q0022
The Department of Veterans Affairs, Network Contracting Office 10, is soliciting quotes for a firm-fixed price contract to provide comprehensive general waste and recycling removal services for the John D. Dingell VA Medical Center and Fisher House #99 in Detroit, Michigan. The scope of work includes the collection, transportation, and disposal of non-hazardous municipal solid waste, corrugated cardboard, scrap metal, and construction/bulk waste. The contractor is responsible for providing all management, labor, vehicles, and equipment, including the rental and maintenance of cardboard compactors and the preventive maintenance of government-owned waste compactors. Regulated medical, hazardous, radioactive, pharmaceutical, and universal wastes are explicitly excluded from the scope. The contract features a base period from April 1, 2027, through March 31, 2028, with four one-year option periods extending the total period of performance to March 31, 2032. Award will be based on the best overall value to the government, evaluating technical capability, pricing, and past performance. Quoters must adhere to Service Contract Act wage determinations for Wayne County and maintain specific insurance coverages, including general liability of $500,000 per occurrence and automobile liability. All quotes must be submitted by November 3, 2026, at 12:00 PM NOON EDT, utilizing the updated Price/Cost Schedule and revised Performance Work Statement provided in Amendment 0001.
Solid Waste Collection

POSTED

1 day ago

DEADLINE

in 5 days
View Details
NAICS: 541380
New
Federal
J065--RO Equipment Maintenance
Solicitation # 36C25027Q0051
The Department of Veterans Affairs, Network Contracting Office 10, is soliciting quotes for a firm-fixed-price contract to provide preventive and non-routine emergency maintenance services for Reverse Osmosis (RO) equipment systems at the Ann Arbor VA Medical Center. The scope of work covers systems serving the Laboratory Department and Sterile Processing Service, requiring all labor, parts, and supervision to ensure uninterrupted process water operation in accordance with OEM, ST108, and AAMI standards. The anticipated period of performance begins January 8, 2027, and runs through January 7, 2032, consisting of a one-year base period and four one-year option periods. While originally designated as a small business set-aside, Amendment 0001 corrected the requirement to be 100% open market and unrestricted. Award will be based on the most advantageous offer, evaluating technical capability, past performance from the last three years, and total price including all options. Offerors must submit their quotes by November 16, 2026, including a signed SF 1449, a strict adherence to the price schedule, and a technical volume not exceeding ten pages. Contractor personnel are required to complete VA Privacy and Information Security Awareness training and provide all necessary licenses and certifications within three business days of award.
Testing Laboratories and Services

POSTED

1 day ago

DEADLINE

in 18 days
View Details
NAICS: 513210
New
Federal
DA10--Legacy VHA VISN 10 - AudioCare Modules and PM&S Services
Solicitation # 36C25027F0076
The Department of Veterans Affairs Network Contracting Office 10 intends to award a sole source contract to Payton Merger SUB II LLC dba AudioCare, an Other than Small Business, for annual maintenance, support license renewals, and preventative maintenance and support services. This requirement supports VA Pharmacy Departments across Legacy VHA VISN 10, including locations in Ann Arbor, Battle Creek, Saginaw, Detroit, Indianapolis, Northern Indiana, Cincinnati, Dayton, Chillicothe, and Columbus, Ohio. The scope specifically covers proprietary software and licenses for AudioPrefill, TM-PreFill, TM-Communicator, and general user licenses. The period of performance is structured as one 12-month base period with one 12-month option period, not to exceed two years in total. Under solicitation 36C25027F0076, the government is utilizing NAICS code 513210 for Software Publishers. While the intent is to sole source due to the proprietary nature of the software, the agency will consider capability statements or quotations from other responsible sources. Any respondent that is not the manufacturer must provide a manufacturer authorization letter dated within the last 12 months on AudioCare letterhead to be considered. Submissions must include the company's SAM UEI number, business size, and detailed corporate experience. Responses are due to Contracting Officer Josh Kovar by October 29, 2026, at 12:00 PM ET.
Software Publishers

POSTED

1 day ago

DEADLINE

in about 2 hours
View Details
NAICS: 541620
New
Federal
H941--Chemical Hoods & HEPA PM
Solicitation # 36C25027Q0065
The Department of Veterans Affairs, Network Contracting Office 10, is soliciting quotes for the preventive maintenance, inspection, testing, and certification of chemical hoods and HEPA filters at the Richard L. Roudebush VA Medical Center in Indianapolis, Indiana. This is a combined service contract set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), requiring that no more than 50 percent of the contract value be paid to firms not listed as SDVOSBs or VOSBs. The scope of work includes recurring semiannual and annual certifications, environmental monitoring, and optional condition-based HEPA filter replacements across pharmacy, research, and engineering systems. Performance is scheduled for normal business hours, though off-hours work may be required to avoid disrupting patient care. The contract utilizes a firm-fixed-price structure for both recurring services and optional line items, such as BSC decontamination and ASHRAE 110 tracer-gas testing. A mandatory site visit was scheduled for November 3, 2026, and quotes were due by November 10, 2026. Award evaluation is based on technical rating, price, and past performance. Successful contractors must submit a Quality Control Plan within 10 business days of award and a reconciled electronic inventory within 30 calendar days. All work must adhere to strict regulatory standards, including VHA Directive 1108.12 and USP 797 and 800, with detailed reporting required for acceptance, including raw measurements and unambiguous certification status.
Environmental Consulting Services

POSTED

2 days ago

DEADLINE

in 12 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS