Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on February 26, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--Electrophysiology Mapping System (Brand Name- EnSite X EP System or Equal) VAMC Little Rock, AR

Awarded
36C25621Q0475Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334510
New
Federal
Hearing Aid Fitting and Verification for Shiprock Service Unit (IEE or ISBEE Set Aside)
Solicitation # SS-SRSU-27-0003
The Indian Health Service Shiprock Service Unit is conducting market research through a sources-sought notice to identify capable Indian-owned economic enterprises, both large and small, to provide hearing aid fitting and verification services. The primary objective is to reduce hearing aid rejection and costly remakes while ensuring patients receive optimal benefit from their devices. The requirement includes the provision of equipment with advanced technical specifications, such as dual ear capability, a frequency range of 200 to 16,000 Hz, and a comprehensive test suite including speechmap counseling and pediatric probe tube placement. Additionally, the selected vendor must provide installation and training for the Audiology Department. This opportunity is categorized under NAICS code 334510 for electronic hearing aid manufacturing. In accordance with the Buy Indian Act, the government will prioritize responses from Indian-owned economic enterprises before considering other small business set-aside programs. Interested parties must be registered in the System for Award Management and submit a company profile, a capability statement, and a completed IHS IEE Representation Form by November 03, 2026. This notice is for market research purposes only and does not constitute a formal solicitation.
Navajo Area Indian Health Svc

POSTED

2 days ago

DEADLINE

in 4 days
NAICS: 334510
New
Federal
Ocular Scanner
Solicitation # W91CRB-26-AWSP-Scanner-Ultrasonic-Ocular-RPP
The Portfolio Acquisition Executive Maneuver Ground Project Manager Maneuver Medical Systems is soliciting prototype proposals for a Scanner Ultrasonic Ocular device under Other Transaction Authority pursuant to 10 U.S.C. 4022. The objective is to award two prototype agreements for the delivery and demonstration of FDA-approved commercial solutions that provide anatomical visualization and diagnostic imaging of the eye, specifically for the anterior and posterior segments. Awardees are required to deliver four prototype units within 45 to 60 days of award for operational and environmental testing conducted in accordance with MIL-STD-810H. The estimated period of performance is twelve months, with awards expected around the first quarter of fiscal year 2027. The procurement utilizes a comparative best-value methodology, prioritizing technical approach, performance compliance, reliability, schedule realism, and past performance over cost. Key requirements include Trade Agreements Act compliance, MIL-STD-130N marking for hardware, and the provision of ruggedized transport cases. Deliverables encompass the hardware units, comprehensive user and maintenance manuals, cybersecurity documentation, and on-site operator training. Proposals must be submitted as four separate PDF volumes via DoD SAFE or secure email by November 12, 2026. This action is a direct Other Transaction Agreement and is not subject to the Federal Acquisition Regulation or Defense Federal Acquisition Regulation Supplement.
W6QK Acc-Apg

POSTED

3 days ago

DEADLINE

in 13 days

General Info

Contract Value

$263,801

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing

Place of Performance

Central Arkansas Veterans Healthcare System John L. McClellan VA Medical Center Electrophysiology Lab 4300 West 7th Street, Little Rock, MS, 72205, USA

Set-Aside

NONE

Award Issued Date

Documents

1

36C25621Q0475.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseAwarded
Posted

Sources Sought

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 256-NETWORK Contract Office 16 (36C256)
Contacts1 person available
OfficeRIDGELAND, MS, 39157, USA
Office AddressRIDGELAND, MS, 39157, USA
Contacts
Sheila ReedContracting Officer

Full Description

Show more
THIS IS A REQUEST FOR INFORMATION (MARKET SURVEY) NOTICE ONLY, NOT A SOLICITATION AND SHOULD NOT BE CONSIDERED AS SUCH. The Government will not pay for any information received in response to this notice, nor will the Government compensate any respondent for any cost incurred in developing the information provided to the Government. This notice does not constitute a commitment by the Government. Any information provided in response to this market survey will be used for informational purpose only and will not be released. Vendor participation is not a promise of future business with the Government. The purpose of this notice is to conduct market research to assist the Government in crafting an appropriate solicitation. Potential contractors shall provide, at a minimum, the following information to the Contracting Officer (CO), Sheila Reed via email at contact@example.gov, Network Contracting Office (NCO) 16. 1) Company name, address, and point of contact, phone number, e-mail address, and DUNS. 2) Please identify your company s size in comparison to the anticipated North American Industry Classification System (NAICS) code: 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing; Small business size standard: 1,250 employees. Please check one of the following: [ ] yes [ ] no Service Disabled Veteran Owned Small Business (SDVOSB) [ ] yes [ ] no Veteran Owned Small Business (VOSB) [ ] yes [ ] no Small Business Manufacturers [ ] yes [ ] no All other Small Business (SB) [ ] Woman-owned SB [ ] Disadv/Minority Owned [ ] yes [ ] no Other than Small Business 3) If not a manufacturer, only authorized representatives/providers/distributors of the manufacturer will be considered. Equipment must be new, no used or refurbished equipment accepted. Please provide a proof of authorized dealer or reseller letter from manufacturer. 4) This is a brand name or equal sources sought. As such, the salient characteristics reflect the physical, functional, or performance characteristics that equal products must meet to satisfy the Government s needs. To be considered for any potential solicitation, offers of equal products, including equal products of the brand name manufacturer, must: (a) Meet the salient physical, functional, or performance characteristic specified in this notice; clearly identify the item by Brand name, if any and make/model number. (b) Include descriptive literature such as illustrations, drawings, or a clear reference to descriptive data or information available that identifies that the equal item meets or exceeds the salient characteristics required by the Government. 5) SCOPE AND SALIENT CHARACTERISTICS: 5.1 The Contractor shall provide, transport, install, and test all listed equipment. All products must meet all salient characteristics defined in this section. 5.2 All equipment and installation shall meet manufacturers and VA specifications. 5.3 The Contractor shall furnish all supplies, equipment, facilities and services required for delivery and installation of the supplies and equipment. 5.4 The Contractor shall be responsible for any missing parts and components not included in order to carry out the installation. 5.5 SALIENT CHARACTERISTICS 5.5.1 Cardiac Mapping Equipment Suggested Manufacturer Brand Name: EnSite X EP System, or EQUIVALENT, as listed below: Specifications/Salient Characteristics: Must interface/integrate seamlessly with the existing Phillips Electrophysiology equipment Capable of displaying 3-dimentional (3-D) position of conventional and Sensor-enabled electrophysiology catheters. Must display cardiac electrical activity as waveform traces and as dynamic 3-D isopotential maps of the Cardiac chambers Able to provide information about the electrical activity of the heart and displays cather location during conventional EP procedures. Capable of software expansions to meet future needs 5.5.2 Amplifier Suggested Manufacturer Brand Name: EnSite X EP system Amplifier, or EQUIVALENT, as listed below: Specifications/Salient Characteristics: Must accept signals from catheters and electrodes attached to the patient and pass the signals to the amplifier. Must convert the signals to a digital format and send them to the workstation for processing and display The Field Frame must generate the magnetic tracking filed during procedures. Module to connect the surface electrodes, system reference surface electrode, and ECG electrodes to the amplifier. 20 pin and 80 pin modules allow for connection of standard diagnostic catheters to the amplifier. One anterior and three posterior sensors with cables ECG cable to connect standard ECG electrodes to the amplifier 5.5.3 Display Workstation - Suggested Manufacturer Brand Name: EnSite X Display Workstation, or EQUIVALENT, as listed below: Specification/ Salient Characteristics Computer workstation, monitors, medical grade isolation transformer, and printer Must contain the system software displaying data from the amplifier Must have a keyboard and mouse Monitor to be placed near the workstation and keyboard Medical grade isolation transformer to allow all system components are connected to the line power. Initial one-year warranty with options for additional years Remote access for real time technical support thru a secure broadband connection. 5.5.4 Ultrasound Imaging Console with Battery - Suggested Manufacturer Brand Name: ViewMate Ultrasound Imaging Console with battery, or EQUIVALENT, as listed below: Specification/ Salient Characteristics Fully featured ultrasound system Optimized for 64-element phased array intra-cardiac echo (ICE) visualization Smart Cart and Smart Cart battery for operation without AC power Software: 30 second cold boot-up time; 2D/B, M, Color doppler (CD), Power Doppler, Pulse Wave (PW), Continuous Wave (CW), AUX CW, ECG, TEE, and Tissue harmonics modes; auto Opt with ZST Hardware: SmartCart battery with up to 1.5 hours of operation without plugging into AC power, connects up to 3 transducers simultaneously, Interface Module for ICE, Min. 120 GB hard drive storage on SmartCart, minimum 19 color, high resultion LCD display mounted on articulating arm, LED display for customizable image mode menus, HDMI/DVI digital video output, Integrated DICOM viewing software, customized baskets to carry supplies. 5.5.5 Linear Transducer - Suggested Manufacturer Brand Name: L8-3 Linear Transducer, or EQUIVALENT, as listed below: Specification/ Salient Characteristics 8-3 MHz linear array transducer designed for peripheral vascular imating 10 frequencies including 2D, M-Mode, Tissue harmonics, compound harmonics, and two each for color/power PW doppler END OF SALIENT CHARACTERISTICS Installation location: Central Arkansas Veterans Healthcare System John L. McClellan VA Medical Center 4300 West 7th Street Electrophysiology Lab Little Rock, AR 72205 The intended award will be a firm-fixed price supply purchase to a single vendor. Please provide a courtesy quote in response to this request to evaluate price reasonableness for any set-aside determination. Responses are due by 03/02/2020 3:00 PM (central) to the Contracting Officer MFG PN Item Qty EnSite System M-01 EnSite X EP System including: EnSite X Amplifier and EnSite X Display Workstation 1 H701336 ViewMate Ultrasound Imaging Console with battery including: Software and SmartCart with battery 1 H702488 L8-3 Linear Transducer 1 This notice is to assist in determining sources only. There is no solicitation currently available. There is no guarantee, expressed or implicit, that the market research for this acquisition will result in a particular set-aside, sole source award or any other guarantee of award strategy. All information is to be provided on a voluntary basis and at no charge to the Government. DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

More opportunities from Department Of Veterans Affairs → 256-NETWORK Contract Office 16 (36C256)

Same awarding agency

NAICS: 238290
New
Federal
N099--JLM Roll Up Door Replacement
Solicitation # 36C25627Q0092
Solicitation 36C25627Q0092 is a combined synopsis and request for quote issued by the Department of Veterans Affairs for the replacement of a motorized roll-up door at the John L. McClellan Veterans Hospital. This is a 100% set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 238290. The project requires the contractor to provide all labor, tools, and equipment, including a scissor lift and forklift, to remove and dispose of the existing door and install one grey 7 by 9 foot motorized rolling steel rapid slat door with insulated slats and an obstruction safety device. The award will be a firm-fixed-price contract with a performance period of 30 days from the Notice to Proceed and includes a one-year warranty. The government will utilize the Lowest Price Technically Acceptable (LPTA) evaluation process, focusing on technical capability, price reasonableness, and the completion of the VA Notice of Limitations on Subcontracting. Interested offerors must submit a three-volume quote package consisting of technical capabilities, a completed price schedule, and the required VAAR certification. Quotes must be emailed to Joseph Warren by 3:00 PM CST on November 18, 2026. A site visit is scheduled for November 6, 2026, at 10:00 AM, and all inquiries must be submitted by November 10, 2026. Performance will take place at the Central Arkansas Veterans Healthcare System in North Little Rock, Arkansas, and contractors must comply with all OSHA, ANSI, CAN, and UL standards.
Other Building Equipment Contractors

POSTED

1 day ago

DEADLINE

in 19 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS