Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on February 22, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--Neurology Electromyography (EMG) System/Orlando Va Healtcare System/One Time Order

Closed
36C24821Q0521Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334510
New
Federal
Hearing Aid Fitting and Verification for Shiprock Service Unit (IEE or ISBEE Set Aside)
Solicitation # SS-SRSU-27-0003
The Indian Health Service Shiprock Service Unit is conducting market research through a sources-sought notice to identify capable Indian-owned economic enterprises, both large and small, to provide hearing aid fitting and verification services. The primary objective is to reduce hearing aid rejection and costly remakes while ensuring patients receive optimal benefit from their devices. The requirement includes the provision of equipment with advanced technical specifications, such as dual ear capability, a frequency range of 200 to 16,000 Hz, and a comprehensive test suite including speechmap counseling and pediatric probe tube placement. Additionally, the selected vendor must provide installation and training for the Audiology Department. This opportunity is categorized under NAICS code 334510 for electronic hearing aid manufacturing. In accordance with the Buy Indian Act, the government will prioritize responses from Indian-owned economic enterprises before considering other small business set-aside programs. Interested parties must be registered in the System for Award Management and submit a company profile, a capability statement, and a completed IHS IEE Representation Form by November 03, 2026. This notice is for market research purposes only and does not constitute a formal solicitation.
Navajo Area Indian Health Svc

POSTED

2 days ago

DEADLINE

in 4 days
NAICS: 334510
New
Federal
Ocular Scanner
Solicitation # W91CRB-26-AWSP-Scanner-Ultrasonic-Ocular-RPP
The Portfolio Acquisition Executive Maneuver Ground Project Manager Maneuver Medical Systems is soliciting prototype proposals for a Scanner Ultrasonic Ocular device under Other Transaction Authority pursuant to 10 U.S.C. 4022. The objective is to award two prototype agreements for the delivery and demonstration of FDA-approved commercial solutions that provide anatomical visualization and diagnostic imaging of the eye, specifically for the anterior and posterior segments. Awardees are required to deliver four prototype units within 45 to 60 days of award for operational and environmental testing conducted in accordance with MIL-STD-810H. The estimated period of performance is twelve months, with awards expected around the first quarter of fiscal year 2027. The procurement utilizes a comparative best-value methodology, prioritizing technical approach, performance compliance, reliability, schedule realism, and past performance over cost. Key requirements include Trade Agreements Act compliance, MIL-STD-130N marking for hardware, and the provision of ruggedized transport cases. Deliverables encompass the hardware units, comprehensive user and maintenance manuals, cybersecurity documentation, and on-site operator training. Proposals must be submitted as four separate PDF volumes via DoD SAFE or secure email by November 12, 2026. This action is a direct Other Transaction Agreement and is not subject to the Federal Acquisition Regulation or Defense Federal Acquisition Regulation Supplement.
W6QK Acc-Apg

POSTED

3 days ago

DEADLINE

in 13 days

General Info

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing

Place of Performance

Department of Veteran Affairs Orlando VA Healthcare System 13800 Veterans Way, Orlando, FL, 32827

Set-Aside

NONE

Documents

1

36C24821Q0521.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 248-NETWORK Contract Office 8 (36C248)
Contacts1 person available
OfficeTAMPA, FL, 33637, USA
Office AddressTAMPA, FL, 33637, USA
Contacts
Tonya BradleyContract Specialist

Full Description

Show more
Sources Sought Notice only. This is neither a solicitation nor a request for quote (RFQ) and does not obligate the Government to award a contract. Request for a solicitation will not receive a response. The Government will not pay nor reimburse any costs of preparing this response. The purpose of this sources sought notice is for market research to make the appropriate acquisition decisions and to gain knowledge of potential qualified and their Small Business Administration (SBA) size classification in relation to North American Industry Classification System (NAICS) 334510, Electromedical and Electrotherapeutic Apparatus Manufacturing, size standard of 1,250 Employees. The Network Contracting Office (NCO) 08, Orlando Veterans Affairs Healthcare System is seeking a source to provide Neurology Electromyography (EMG) System to the Department of Veterans Affairs Orlando VA Healthcare System, 13800 Veterans Way, Orlando, FL, 32827. Seeking qualified businesses to provide the following: The contractor shall deliver the following item Brand Name or Equal: The salient features of the set are as follows: Desktop Base Unit The desktop base unit should provide the following components: Two electrical stimulators; one auditory stimulator and one visual LED stimulator. (External monitor for pattern display and or goggles.) Up to 12 switchable output sites. (Applicable for IOM. Not in NCS) Built-in audio speaker for output of both live signals as well as playback of recorded data (line-out, line-in, and speaker out connections), with Audio speaker Notch filter adjustable to 50 Hz, 60 Hz, or off. Able to connect via USB (2.0) connection to computer. Two trigger inputs and two trigger outputs for connection to external devices. Input/output for additional devices to connect (patient response unit, footswitch, control panel, reflex hammer, bone conductors, etc.) Disconnect/reconnect feature to stop any stimulation after a few seconds of lost communication between base unit and the computer. Built-in Digital Signal Processor. Computer Monitor Minimum display resolution of 1024 x 768 pixels Amplifier The amplifier connects to the base unit, and should have the following components: 5-channel minimum with 2 non-switched amplifier channels (option of up to 16 channels) Utilizes a 24-bit Analog to Digital Converter. 4800 data points per trace in routine motor and sensory nerve conduction study (i.e. 48 kHz sampling rate for saved data). Disconnect/reconnect feature that will allow amplifier to be disconnected or reconnected without powering off the base unit. Stimuli artifact suppression hardware to prevent stimuli artifact from saturating the amplifier. This allows for a quicker baseline recovery making it easier to detect and measure small responses. Electrode impedance measurement minimum at 20 Hz with a range from 500 to 450 k . Rectangular calibration pulse selectable between 2, 20, 200, 2,000, 20,000 µV. Sensitivity adjustment from 1 µV/division to 10 mV/division in at least 13 steps. (Update) Adjustable filter settings for fixed and switched, and high and low. Stimulator (Electrical) Supports constant voltage and constant current mode Two stimulators can be used for collision based techniques Stimulus output: monophasic or biphasic; single, double or train mode. Conditioning mode delivers two pulses of different intensity from the same stimulator) Programmable buttons. Analog output Available for all channels and in all tests A patient bedside control panel to navigate through software during patient testing. Contains numerical keypad for entering distance. Dedicated keys for single and recurrent stimulation Switch side. 2 Customizable function keys. Dedicated controls of sweep, sensitivity, stimulation, site selection, impedance check, stimulus duration, etc. Single/Triple Footswitch Allows extensive control of the application using a foot. Should be rated IP68 for dust and water immersion. Triple Footswitch allows 2 pedals for customizable functions. Operating System Software The C&A requirements do not apply, and a Security Accreditation Package is not required. Software options and functionality may vary, and should have the following specifications: Windows 10, Office 2016 Clinical tests should include: Motor Nerve Conduction: Reference values based on age, gender, height and body mass index as recommended by American Association of Neuromuscular and Electrodiagnostic Medicine. Compare findings with previous study. Supports pediatric reference values. Sensory Nerve Conduction: Same as above. Reduce artifact via signal Enhance software feature, on-line and off-line averaging. Replicate and average responses for reproducibility. Supports pediatric reference values. Combined motor and sensory NCS. Carpal tunnel sensory index (CSI). Multi-channel F-Wave: Enhance software feature responses for better assessment H Reflex: Support reflex hammer for stimulation Blink Reflex: Support reflex hammer for stimulation Repetitive Nerve Stimulation: Calculate facilitation within and across a train. Automation in long and short exercise test. Needle EMG: With dual time base. Anatomy images for muscle localization. Store and replay EMG with audio and signal manipulation (1 channel: 960 second, 2 Chan: 600 seconds) Macro EMG: Save and re-play/analyze recording using 2 channels of recordings. Includes entry of fiber density. Volitional and Stimulated Single Fiber EMG: Jitter measurements using level and peak. Multimodality Evoked Potentials: AEP, SEP, VEP, P300, ERG/EOG: Artifact reject per channel. Display of residual noise, Quantitative noise estimate (Fsp). Save individual responses. Multiple averaging algorithms. Replicate and average multiple trials to increase signal quality and reproducibility. Multi-Modality: Sympathetic skin response (single & multi-channel), R-R interval analysis (using Root mean square of successive difference and other calculations), Bareitschafts potential Conduction Velocity Distribution: Automated collision protocol to study conduction is slow fibers. Bareitschafts Potentials: Multi-channel recordings. Save EMG signals for replay and re-analysis. R-R Interval: Analysis using Root mean square of successive difference and other calculations. Valsalva ratio measurement. Sympathetic /Galvanic Skin Response: Multi-channel recordings. Low frequency setting of 0.05 Hz is possible. Spike Triggered Averaging: Motor unit potential analysis. Multi-channel recordings. Level & peak trigger (above and below baseline). Intraoperative Monitoring Motor Unit Number Index (MUNIX): Fastest way to study motor unit loss in patients with motor neuron disease. Motor Unit Number Estimation (MUNE): Incremental stimulation, multiple point stimulation, Spike triggered averaging. CMAP Scan: Study of motor unit loss in motor neuron disease. Report Generation On-line mode: Instantaneous synchronization between patient waveforms and reports. One button access to waveform from the report. Stand-alone: Generate report when needed. Includes tables, traces, references values and highlights normal and abnormal findings. Automatic summary generation of clinical findings based on AANEM reference values. One click export of report across network via docx or pdf format. Patient workflow List patients based on their status: Appointment, In Progress, Acquisition Complete, Finalized (Report completed) Build a patient list using Search parameters, e.g. gender. Examining physician, etc. Patient data protection SQL database Hide patient list Close system when not in use. Requires password to re-start Waveform Acquisition and Display: High Definition (HD) EMG recordings: 4800 data points per trace in routine motor and sensory nerve conduction study (i.e. 48 kHz sampling rate for saved data). Routine needle EMG signals can be saved at 48 kHz sampling rate for playback and analysis. Dual time base in needle EMG for better assessment of EMG waveforms Free-run monitor in all tests for baseline quality Cascades, long trace display in EMG Compare findings from left and right sides. Compare findings with previous examinations. Backward compatibility for review of old patient data and test protocols Network Compatibility and Data Integrity: Uploading of patient data and reports via bidirectional HL7 compatible with Vista Imaging and CPRS. Backward compatibility of existing patient data. Migration of archived patient data must be direct transfer preserving all original formats, data integrity, and without the use of third party conversion software. Ability to retrieve, merge, or move archived Patient Visits and Tests with new studies forming a seamless progressive care record. Vendor software must meet consolidated and coordinated guidance for VA information technology concerning approved and prohibited technologies and standards that the VA owns, operates, patches, manages and version controls on the VA production network as directed by the VA Technical Reference Model v 21.2. https://trm.oit.va.gov/TRMHomePage.aspx System must have the ability to retrieve customized end-user defined settings already built into the current system. Must meet all HL7 connectivity/compatibility standards with our VISTA/CPRS system including dynamic message formatting. Power Requirements The base unit can be powered by 100-120 V, 220-240 V, 50/60 Hz Environmental Limits Operating (in use): Temperature should be 60 to 90 F (15.6 to 32.2 C). Non-Operating (in storage): Temperature should be 0 to 132 F (17.7 to 55 C). Compliance/Regulatory Standards Unit should meet the following domestic (USA) standards: 510(k) Clearance UL 60601-1 Medical Electrical Safety Standard Interested parties may respond by submitting a qualifications letter to include the following information: Company Name Address Point of Contact Phone, Fax, and Email DUNS Number Authorized Distributor Letter Capability Statement specific to the technical requirements. This must not be a generic line card but something that the government can positivity use to determine the procurement strategy of this requisition. Socio-Economic Category (i.e., SDVOSB, VOSB, HUBZone, etc...) Provide verification that your firm can prove the requested item(s) to include past and/or current contract for the same requirements and any other convincing evidence to help the Government determine your company s capabilities. To be eligible for award, prospective offerors must be registered in the System for Award Management (SAM) Internet Site, www.sam.gov. Responses to this notice shall be sent to via email, no later than 1:00 PM Eastern Standard Time on February 24, 2021. Telephone and facsimile responses will not be considered. Responses shall be submitted via email only to contact@example.gov. When responding via email ensure the subject line is titled with RFI# 3624821Q0521 Neurology Electromyography (EMG) System for the Orlando VA Healthcare System. No other information is available at present time. Thank you for your interest and time to prepare and submit a response.

More opportunities from Department Of Veterans Affairs → 248-NETWORK Contract Office 8 (36C248)

Same awarding agency

NAICS: 621399
New
Federal
Q524--FY27: Perfusionist Services| NFSG
Solicitation # 36C24827Q0013_1
The Department of Veterans Affairs Network Contracting Office 8 is soliciting quotations for Perfusion and Autotransfusion Services to support the Malcolm Randall VA Medical Center in Gainesville, Florida. This is a firm-fixed-price contract set aside exclusively for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The contract structure includes a base year running from January 7, 2027, to January 6, 2028, with three subsequent one-year option periods. The contractor is required to provide qualified personnel who must be onsite during all scheduled operating room hours and remain within 30 minutes of the facility. Key requirements include mandatory certification from the American Board of Cardiovascular Perfusion for perfusionists and specific certifications for autotransfusionists. The contractor must adhere to strict clinical standards, including Ongoing Provider Performance Evaluation documentation, and comply with comprehensive security, cybersecurity, and patient confidentiality regulations such as HIPAA and the Privacy Act. Performance will be monitored via a Quality Assurance Surveillance Plan (QASP) focusing on provider quality and patient access. Award will be based on the most advantageous quote, where technical capability and past performance are weighted as significantly more important than price. Technical evaluation focuses on candidate qualifications, experience, and the company staffing plan. To remain eligible, the prime contractor must certify that no more than 50 percent of the contract value is paid to firms that are not certified SDVOSBs. Invoices are to be submitted monthly in arrears by the 20th workday of the following month.
Offices of All Other Miscellaneous Health Practitioners

POSTED

1 day ago

DEADLINE

in 14 days
View Details
NAICS: 339112
New
Federal
J065--Copy of FY26: MBC Sternudrive LiteTM; Model MBC 709-Modular
Solicitation # 36C24827Q0095
The Department of Veterans Affairs Network Contracting Office 8 is conducting market research through a Sources Sought Notice to identify qualified businesses capable of providing the De Soutter Medical MBC Sternudrive Lite Model MBC 709-Modular or an equal alternative for the VA Caribbean Healthcare System in San Juan, Puerto Rico. This notice is for research purposes only and does not constitute a formal solicitation or an obligation to award a contract. The government has a preference for domestic products that meet or exceed the salient characteristics of the brand-name equipment. The required items include three MBC 709-Modular handpieces, three reciprocating sternum saws, three sternum guards, three oscillating sagittal sternum saws, four large battery packs, and three sterilization systems. Interested businesses must be registered in the System for Award Management and fall under NAICS code 339112 for Surgical and Medical Instrument Manufacturing, which has a size standard of 1,000 employees. To respond, companies must submit a qualifications letter to Darrin Alexander by November 12, 2026, at 13:00 EST. The submission must include the company's name, address, point of contact, UEI code, socio-economic category, and a capability statement with evidence of past or current contracts for similar requirements. Responses must be sent via email with the subject line RFI# 36C24827Q0095 FY 26: MBC Sternudrive LiteTM; Model MBC 709-Modular.
Surgical and Medical Instrument Manufacturing

POSTED

1 day ago

DEADLINE

in 13 days
View Details
NAICS: 236220
New
Federal
5680--FY27 NRM (PROJ 573-24-110) BB - Expand Cardiology Service
Solicitation # 36c24826r0124
Solicitation 36C24826R0124 is a firm-fixed-price requirements contract issued by the Department of Veterans Affairs Network Contracting Office 8 for the renovation and expansion of the Cardiology service administrative space at the Malcom Randall VA Medical Center in Gainesville, Florida. The project involves approximately 6,000 square feet of construction on the third floor of Building 1, encompassing selective demolition, site preparation, architectural finishes, and comprehensive mechanical, electrical, plumbing, fire protection, and technology systems work. The estimated project magnitude is between 2,000,000 and 5,000,000 dollars, with a base performance period of 540 to 548 calendar days from the Notice to Proceed. This procurement is strictly set aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB). Award will be determined using a trade-off process where technical factors—including relevant past performance, technical approach, project planning, safety, infection control, quality control, and project schedule—are combined and weighted approximately equal to price. Offerors must submit a bid guarantee of 20 percent of the bid price or 3,000,000 dollars, whichever is less, and provide a current Experience Modification Rate (EMR) of 1.0 or less. Due to the operational hospital environment, strict adherence to ICRA/PCRA controls, safety protocols, and minimal disruption to services is required. The closing date for the receipt of proposals has been extended to November 16, 2026, at 3:00 PM EST.
Commercial and Institutional Building Construction

POSTED

2 days ago

DEADLINE

in 17 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS