Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

6515--Wechsler Memory Scale

Active
36C24827Q0096Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

NAICS

334515 - Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals

Place of Performance

Department of Veterans Affairs Network Contracting Office 8 (NCO 8), Orlando, FL, 32827

Set-Aside

NONE

Documents

1
PDF, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseSources Sought
Posted

Sources Sought

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 248-NETWORK Contract Office 8 (36C248)
Contacts1 person available
OfficeTAMPA, FL, 33637, USA
Office AddressTAMPA, FL, 33637, USA
Contacts
Carl MyersContract Specialist

Full Description

Show more
This is a SOURCES SOUGHT NOTICE ONLY. It is neither a solicitation nor a request for quote (RFQ) and it does not obligate the Government to award a contract. Request for solicitation will not receive a response. The Government will not pay nor reimburse any costs of preparing responses. This source s sought notice is for market research purposes to make the appropriate acquisition decision and gain knowledge of potential qualified businesses and their Small Business Administration size classification in relation to North America Industry Classification System (NAICS) 334515 Instrument manufacturing for Measuring and Testing Electricity and Electrical Signals with an associated size standard of 1000 employees. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 8 Orlando Contracting Team is seeking to identify interested contractors who can provide Wechsler Memory Scale for the Orlando VA Medical Center (OVAMC). If your business can meet or exceed the requirement, please provide a capability statement.
The capability statement shall be limited to no more than five pages and must clearly state the following: Capability in industry to manufacture or provide the required Wechsler Memory Scale. Offerors who cannot provide historical information from their company regarding the outlined attachment or similar scope and scale should provide corresponding information to show how the company would meet the OVAMC requirements. This information should provide level of confidence in the Government that an offeror would meet or exceed the delivery requirements to provide the required Wechsler Memory Scale.
Salient Technical Characteristics for the Wechsler Memory Scale System Specifications: The Wechsler Memory Scale Fifth Edition (WMS 5) is a comprehensive adult memory assessment designed for individuals ages 16-90, The Standard Kit includes updated normative data, flexible administration formats (Standard, Short, and Alternate Forms), expanded clinical indices, and paper based scoring.
Functional and Performance Characteristics: The Wechsler Memory Scale Fifth Edition (WMS 5) is a comprehensive adult memory assessment designed for individuals ages 16-90, The Standard Kit includes updated normative data, flexible administration formats (Standard, Short, and Alternate Forms), expanded clinical indices, and paper based scoring. Adult Memory Assessment Standardized, individually administered clinical assessment designed to evaluate memory and working memory in individuals aged 16 years through 90 years, 11 months. Comprehensive Memory Evaluation Measures key memory domains including: Auditory Memory Visual Memory Visual Working Memory Immediate Memory Delayed Memory Clinical Index Scores Provides standardized index scores for: Auditory Memory Index (AMI) Visual Memory Index (VMI) Visual Working Memory Index (VWMI) Immediate Memory Index (IMI) Delayed Memory Index (DMI) Multiple Administration Formats Must include comprehensive and abbreviated administration options, consisting of: Standard Form Short Form Alternate Form Memory Screening capability Auditory Memory Measurement Must assess learning, immediate recall, delayed recall, and recognition memory for verbally presented information through narrative and paired-associate memory tasks. Visual Memory Measurement Must assess immediate recall, delayed recall, and recognition of visual stimuli including designs, figures, or equivalent visual memory tasks. Visual Working Memory Measurement Must include standardized measures of visual-spatial working memory and visual sequencing abilities. Normative Database Normative data must be representative of the contemporary U.S. population and stratified by age and demographic characteristics. Digital and Paper Administration Must support paper administration and digital administration/scoring options. Clinical Utility Must provide ancillary, process, and contrast scores that assist in neuropsychological, rehabilitation, clinical, educational, and forensic evaluations. WAIS Compatibility Must allow direct comparison of intelligence and memory performance through compatibility with contemporary Wechsler Adult Intelligence Scale (WAIS) instruments or equivalent cognitive assessment tools. Standardized Scoring and Reporting Must provide standardized scoring procedures, age-based norms, percentile ranks, and interpretive information sufficient for clinical diagnostic use. In addition, provide and answer the following: 1. Company name, address, point(s) of contact, title, telephone number, fax number, email address, cage and SAM UEI number. 2. Company s business size, to include number of employees. 3. Company's socioeconomic status. 4. If SDVOSB/VOSB is planning to provide a response they need to demonstrate the ability to provide a product manufactured by a small business to be considered capable. Submit this information to Contract Specialist, Carl Myers, via email to contact@example.gov. Your response to this notice must be received in writing on or before 1:00 PM (Eastern Standard Time) on November 12, 2026.

Similar Contracts

Same NAICS industry code

NAICS: 334515
New
International
Fast and High-resolution Oscilloscope
Solicitation # 26-58164
The National Research Council of Canada is soliciting offers for the purchase of one new, current-production, real-time mixed-signal oscilloscope. This equipment is required for a pulsed-mode measurement set-up to characterize quantum cascade lasers and extract key parameters at cryogenic temperatures. The contract will be awarded to the compliant offer with the lowest evaluated price, provided it meets all mandatory technical criteria. All equipment must be delivered to the National Research Council Canada Building M50 in Ottawa, Ontario, on or before March 31, 2027, under Incoterms 2020 DAP. The contract term extends from the date of award until one year after delivery and acceptance. The successful contractor must adhere to strict compliance standards, including Canada's Code of Conduct for Procurement, the Ineligibility and Suspension Policy, and the Canadian Electrical Code Part 1. Packaging must be environmentally preferable, utilizing materials that are reusable, returnable, or recyclable. Proposals must be submitted electronically by November 13, 2026, divided into technical, financial, and declaration sections. Payment for undisputed invoices will be made within 30 days of receipt. Security requirements are governed by the Security Requirements Check List, and the procurement is classified as unclassified.
National Research Council of Canada

POSTED

about 14 hours ago

DEADLINE

in 9 days
View Details
NAICS: 334515
New
Federal
Metrology Grade Oscilloscope
Solicitation # 26E-187A-RF
The Air Force Metrology and Calibration (AFMETCAL) program office is conducting market research through a Sources Sought synopsis to identify potential providers for 131 highly accurate, standardized metrology-grade oscilloscopes over four years. The objective is to replace aging equipment and establish a consistent technical baseline across all Precision Measurement Equipment Laboratories (PMELs), which will streamline training, simplify Technical Order authoring, and ensure identical bench setups across the enterprise. This request is for planning purposes only and is not a solicitation for proposals. Technical requirements for the hardware include a bandwidth of 1.5 to 2 GHz, a sample rate of 5-10 GS/s, and a native resolution of at least 12-bit, with 16-bit in high-res mode. The preferred unit size is 15 by 8 by 6 inches with a minimum 10-inch high-resolution multi-touch display. Connectivity must include native GPIB, LXI Core compliant Ethernet, and USB 3.0. Each unit must be delivered with an ISO/IEC 17025 accredited Certificate of Calibration traceable to NIST or AFPSL. Support requirements include a minimum three-year warranty and guaranteed spare parts availability for at least seven years. Interested vendors, including both large and small businesses under NAICS code 334515, must submit a capability statement and rough order of magnitude pricing. Submissions should include company details, sales history, and technical specifications of the offered product. Responses are due by December 3, 2026, at 2:00 pm ET and should be directed to the listed contract specialists. Reconditioned or used materials are strictly prohibited.
FA2263 Aflcmc Romk Afmetcal

POSTED

1 day ago

DEADLINE

in about 1 year
View Details

More opportunities from Department Of Veterans Affairs → 248-NETWORK Contract Office 8 (36C248)

Same awarding agency

NAICS: 621512
New
Federal
Q522--3T Mobile MRI Trailer and Technologist Services
Solicitation # 36C24827Q0018
The Bruce W. Carter Department of Veterans Affairs Medical Center within the Miami Veterans Affairs Healthcare System is seeking a contractor to provide 3T Mobile Magnetic Resonance Imaging (MRI) services for eligible beneficiaries. This requirement, identified by RFQ 36C24827Q0018, involves the provision of a 3T MRI trailer and qualified Board Certified MRI Technologists on-site. The expected period of performance runs from April 15, 2027, through April 14, 2032. The procurement is designated as a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 621512, with a business size standard of 19 million dollars. The contractor must propose at least three key personnel for credentialing and scheduling, ensuring a minimum of two Board Certified MRI Technologists are available, with a third recommended for coverage. All technologists must hold current ARRT registration for MRI, be certified in Basic Life Support, and be fluent in English. Compliance with VHA Directive 1100.20 for credentialing and adherence to the facility's Medical Staff By-Laws are mandatory. Documentation of certifications must be provided to the government annually. Eligible offerors must be registered in the System for Award Management (SAM) per FAR 52.204-7 to be considered for award.
Diagnostic Imaging Centers

POSTED

about 7 hours ago

DEADLINE

in 2 days
View Details
NAICS: 562112
New
Federal
S222--FY27 Bio-Hazardous Waste Services
Solicitation # 36C24827Q0107
The Department of Veterans Affairs, Network Contracting Office 8, is conducting market research via a Sources Sought Notice for bio-hazardous waste services at the James A. Haley VA Medical Center and several associated outpatient clinics and community based clinics in Florida. The scope of work involves the pickup, transport, incineration, and disposal of biomedical infectious, veterinary, chemotherapy, biological/pathological, and contaminated wastes. The anticipated performance period consists of a base year and four one-year option periods from February 15, 2027, to February 14, 2031. The government is specifically seeking information from Service Disabled Veteran-owned Small Businesses, Veteran-owned Small Businesses, and Small Businesses under NAICS code 562112. The contractor will be responsible for providing UN and DOT approved reusable containers of various sizes, including 130gl, 96gl, and 30gl models, as well as leak-resistant 4.12cf boxes and specialized storage bins. Key requirements include a 24-hour response time for Category A-B incident responses and a one-working-day turnaround for urgent exchange needs. Compliance with EPA, DOT, and CDC guidelines is mandatory, and the contractor must maintain a certifiable weighing system for tare weight billing. Documentation requirements include signed manifests for every collection and detailed monthly activity reports. Interested vendors must be registered in SAM and submit their company information, capability statement, and contact details by November 10, 2026.
Hazardous Waste Collection

POSTED

1 day ago

DEADLINE

in 6 days
View Details
NAICS: 562111
New
Federal
S205--Waste Management and Recycling Services
Solicitation # 36C24827Q0047
The Department of Veterans Affairs, Network Contracting Office 8, is soliciting quotations for a firm-fixed-price contract to provide non-infectious waste management and recycling services at the C.W. Bill Young VA Medical Center in Bay Pines, Florida, and the Lee County Healthcare Center in Cape Coral, Florida. This acquisition is 100% set aside for SBA-certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 562111. The scope of work includes the collection, hauling, and disposal of non-hazardous waste and the processing of recyclable materials such as plastic, glass, metal, office paper, cardboard, and yard waste. The contractor is responsible for providing all necessary personnel, vehicles, and equipment, including containers and compactors, as the government will not furnish recycling equipment. The contract is structured with a base year and four option years, with performance scheduled to commence on December 30, 2026. Key requirements include adhering to a strict collection schedule, responding to on-call pick-ups within 24 hours, and submitting electronic monthly waste and recycling reports by the fifth working day of the following month. Award will be based on a comparative best-value determination considering technical capability, past performance from the last five years, and total quoted price. Following Amendment 0001, the deadline for quotation submission has been extended to November 12, 2026, at 12:30 PM EST. Submissions must be emailed to the contracting officer and must include a signed VAAR 852.219-75 Certificate of Compliance to be considered for evaluation.
Solid Waste Collection

POSTED

1 day ago

DEADLINE

in 8 days
View Details
NAICS: 334517
New
Federal
DB02--FY27 RayStation Support and Maintenance Services
Solicitation # 36C24827Q0108
The Department of Veterans Affairs, VISN 8 Network Contracting Office, intends to award a sole source contract to RaySearch Americas, Inc. for RayStation Support and Maintenance Services at the James A. Haley Veterans Hospital in Tampa, Florida. Under the authority of FAR Part 13.106-1(b)(1), the contract will cover a base period from December 1, 2026, to November 30, 2027, with four additional option years. The scope of work includes providing all labor, equipment, and consumables for the RaySearch Raystation Treatment Planning System, specifically focusing on application and operating system software updates, patches, and upgrades to ensure system reliability and performance. Support requirements include remote and on-site labor, preferential scheduling of service calls, and a priority two-hour telephone response time. This special notice serves as market research to identify other qualified providers, particularly Service-Disabled Veteran-Owned, Veteran-Owned, 8(a), and HUBZone small businesses. Interested firms must submit documentation of their technical expertise and written proof of being an authorized software support and maintenance provider for the RayStation Treatment Planning System by 12:00 PM EST on November 9, 2026. The acquisition falls under NAICS code 334517 for Irradiation Apparatus Manufacturing, with a size standard of 1,200 employees. All potential respondents must be registered in the System for Award Management. No funds have been authorized or appropriated for this effort at this time.
Irradiation Apparatus Manufacturing

POSTED

1 day ago

DEADLINE

in 5 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS