Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on March 16, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6525--CT Scanner Power Injection System

Closed
36C24426Q0400Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334517
New
SLED
IWQ 138680 Purchase of Infrared Camera
Solicitation # IWQ 138680
Gwinnett County Government is soliciting informal written quotations for the purchase of one Fluke infrared camera or an approved equivalent for use in a predictive maintenance program. The equipment will be used to identify electrical hot spots, overloaded connections, and mechanical abnormalities. The vendor must provide the thermal imager along with full desktop analysis and reporting software. The device must meet specific technical standards, including IEC 60529 IP54 enclosure rating, IEC 61010-1 safety rating, and IEC 61326-1 and CISPR 11 Group 1, Class A electromagnetic compatibility, as well as FCC CFR 47, Part 15 Subpart B. The contract is awarded to the lowest responsive and responsible vendor, with evaluation factors including price, technical specifications, delivery time, and vendor responsibility. Delivery is FOB Destination to the Gwinnett County Water Resources Central Facility in Lawrenceville, Georgia, and the unit price must include all delivery charges. Required bonding includes a 5% bid bond, and 100% performance and payment bonds. Vendors must provide full item identification, including brand and model, and submit sealed packages to the Purchasing Division by the October 28, 2026, deadline. Payment is available via ePayables virtual credit card or direct deposit. The county reserves the right to terminate the agreement for convenience with 30 days written notice.
Gwinnett County Government

POSTED

4 days ago

DEADLINE

in about 19 hours
NAICS: 334517
New
Federal
X-ray imaging detector system
Solicitation # SLAC_369006_Xray_Imaging_Detector_System
SLAC National Accelerator Laboratory, operated by Stanford University for the Department of Energy, is soliciting quotes for an X-ray imaging detector system. The required equipment includes one XRD 4343CT-F22-C-000 imaging grade digital X-ray detector, an XRD-EPS 215W power supply, and associated AC, DC, extension, and PC connection cables, along with an XRD FG(E) OPTO PCIe Frame Grabber V4. Technical requirements specify a flat-panel detector configuration with an amorphous silicon sensor, a minimum active area of 40 cm x 40 cm, a 150 micron pixel size, and applicability for hard and high-energy X-ray diffraction greater than 20 keV. This is a product-only procurement with no on-site services permitted. Quotes are due by October 16, 2026, and will be evaluated based on the Lowest Priced Technically Acceptable method and the best lead time. The resulting purchase order will be a fixed-price contract with NET-30 payment terms. Domestic shipments are FOB Destination Prepaid and Add, while foreign shipments are CIP SLAC, Menlo Park, Duty Unpaid. Offerors must be registered in the System for Award Management and provide a completed Representations and Certifications Rider. Additionally, proposals should include HTS Codes, ECCNs, and a statement regarding duties and tariffs. Buy American Act certification is required for unit prices exceeding 15,000 dollars. While not direct Federal procurements, these subcontracts incorporate various FAR and DEAR clauses based on contract value thresholds, including specific regulations regarding equal opportunity, whistleblower rights, and export controls.
Slac National Accel Labor -Doe Contractor

POSTED

5 days ago

DEADLINE

in 3 days

General Info

NAICS

334517 - Irradiation Apparatus Manufacturing

Place of Performance

Department of Veterans Affairs Altoona VA Medical Center, Altoona, PA, 16602, USA

Set-Aside

NONE

Documents

1

Sources Sought Notice 36C24426Q0400 for CT Scanner Power Injection System

DOCX, High priority: read this firstsources-sought
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)
Contacts1 person available
OfficePITTSBURGH, PA, 15215, USA
Office AddressPITTSBURGH, PA, 15215, USA
Contacts
Jefferson MannContract Specialist

Full Description

Show more
Page 5 of 6 Page 1 of In accordance with FAR 10, Market Research, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to the Sources Sought Notice. The purpose of this announcement is to gain market research knowledge of potential qualified sources and their size classification. The Department of Veterans Affairs, Altoona VA Medical Center, 2907 Pleasant Valley Blvd, Altoona, PA 16602, is seeking potential sources capable of providing a CT Scanner Contrast Power Injection System in accordance with the Draft Statement of Need (SON) below.
Please include the following information in your response: Company name Address Contact person name, phone number and email address SAM UEI # Business size/classification/type (i.e. 8a, Hubzone, SDVOSB, VOSB, etc.) FSS/eCAT/SAC/NAC/NITTAC/NASA SEWP or any Government held contract, if applicable provide the number. NAICS: 334517 Size Standard: 1200 Employees Provide brochures, pamphlets, hyperlinks, or any other materials necessary to determine material capabilities including special features and any express or implied warranties.
Please answer the following questions: Are you the manufacturer, distributor, or equivalent solution to the above items? If not, can you provide additional information, as shown below? This confirms compliance with the nonmanufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers. If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, Point of Contact, and size status (if available). If you re a small business, are you an authorized distributor/reseller for the items identified above? If so, please include your letter of authorization on the OEM s letterhead. If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter, assemble, or modify the items requested in any way? If you do, state how and what is changed, assembled, or modified.
Responses to this Sources Sought Notice shall be submitted directly via email to contact@example.gov. Responses that only include generic marketing material and do not provide for capability to meet requirements listed in the SON may not be considered. Responses must be received no later than 8:00 am ET, 03/23/2026. No solicitation document is available at this time. This notice is simply for Market Research Purposes Only. All information received in response to this RFI that is marked as proprietary will be handled accordingly. The VA will not reimburse any potential contractors for any costs associated with this Sources Sought Notice.
Statement of Need
CT Scanner Contrast Power Injection System Radiology Department Altoona VA Medical Center
Summary The Stellant Flex system is the current system being used in the Radiology CT scanner room at Altoona VA Medical Center (VAMC). The current system has reached end of life and Altoona VAMC requires a new system with the newest technology.
Project Scope The contractor shall provide delivery of a complete Power Injection System and all related Installation to make system fully ready for patient use in accordance with Original Equipment Manufacturer (OEM) specifications. The CT Scanner Contrast Power Injection System shall at a minimum meet all the following salient characteristics. The Stellant FLEX- Medrad Stellant FLEX Injection System is a Name Brand Product provided for reference of salient characteristics only.
Salient Characteristics Power injectors Designed for complex contrast enhanced CT protocols Creates a tight contrast bolus Enables precisely timed contrast delivery Provides more uniform attenuation of the right and left ventricles Minimizes artifacts by achieving proper attenuation levels Visualize the right coronary arteries and right ventricles in a single study by achieving more uniform attenuation Informatics ready platform enables interconnectivity between your CT scanner, power injector, PACS, RIS, & speech recognition systems Storage and recall of up to 250 protocols Enhanced protocol manager Snap-on/twist-off syringe design Automatic plunger advance and retract when attaching and detaching syringes Automatic filling and priming Multi-phase programming (with hold/pause feature) Integrated saline test inject Programmable pressure limit On-board eGFR and weight-based dosing Injection enabled when head is tilted down Automated data capture Interface with PACS/RIS/SR Export of a DICOM secondary capture to PACS
Delivery/Installation Shall be coordinated upon award and at least 5 business days prior to shipment

More opportunities from Department Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)

Same awarding agency

NAICS: 236220
New
Federal
Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC
Solicitation # 36C24426R0088
The Department of Veterans Affairs Network Contracting Office 4 is soliciting proposals for the replacement of Electrical Substations 1 and 2 at the Corporal Michael J. Crescenz Medical Center in Philadelphia, Pennsylvania. This project aims to increase electrical capacity to support current and future facility demands by replacing 29-year-old equipment with new 480/277V substations, each featuring a 1500 kVA transformer. To ensure continuous medical center operations and minimize service outages, the contractor must install a temporary 480/277V substation with a 1500 kVA transformer, which will remain as a spare unit upon project completion. The period of performance is 1,000 calendar days from the issuance of the Notice to Proceed. This is a negotiated RFP set aside 100% for VIP-listed Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 236220. Award will be based on a Best Value Tradeoff, with technical proposals evaluated separately from price proposals. Key evaluation factors include the phasing and live electrical cutover strategy, utility shutdown coordination, infection control and PCRA implementation, and environmental and hazardous waste compliance. Proposals are due by November 20, 2026, at 4:00 PM EST. Requirements include the provision of 100% performance and payment bonds, a 20% bid guarantee, and the identification of key personnel, including a Project Manager, Licensed Electrical Supervisor, and Quality Control Manager.
Commercial and Institutional Building Construction

POSTED

about 13 hours ago

DEADLINE

in 24 days
View Details
NAICS: 236220
New
Federal
Z2DA--FY26 NRM 460-20-004 | Tuckpointing FY26 | NCO 4 Construction East (VA-26-00060656)
Solicitation # 36C24426B0018
Solicitation 36C24426B0018 is a sealed bid invitation for a firm fixed-price construction contract to perform tuckpointing, masonry, and caulking repairs at the Wilmington VA Medical Center in Delaware. This project, identified as Project 460-20-004, involves the repair and replacement of deteriorated exterior masonry and caulking systems across ten campus buildings. The estimated magnitude of construction is between 2,000,000 and 5,000,000 dollars, with a required period of performance of 270 calendar days from the Notice to Proceed. The contract is a 100 percent set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 236220. Award will be granted to the responsive and responsible bidder offering the lowest price. Key requirements include the provision of performance and payment bonds, compliance with the Davis-Bacon Act, and adherence to the Buy American Act. The contractor must provide a dedicated quality control person with a QC/OQA background to validate work and generate a final punch list. Technical specifications mandate that all materials be installed according to manufacturer standards and local building codes, with a required cleaning mock-up to establish the quality standard. Bids must be submitted electronically, and offerors must be registered in the System for Award Management (SAM) and verified through VetCert at the time of proposal.
Commercial and Institutional Building Construction

POSTED

about 13 hours ago

DEADLINE

in 9 days
View Details
NAICS: 334516
New
Federal
6550--VISN 4 Coagulation Testing
Solicitation # 36C24427Q022
Solicitation 36C24427Q022 is a request for a five-year Indefinite Delivery Indefinite Quantity (IDIQ) contract to provide advanced automated primary coagulation testing systems for nine VA Medical Centers within VISN 04. The anticipated period of performance runs from December 1, 2026, to November 30, 2031. The contractor is required to provide FDA-approved instrumentation, including delivery, installation, and removal, along with all necessary reagents, standards, quality controls, and consumables. A key requirement is the implementation of a bi-directional, bar-coded computer interface compatible with the VA laboratory information system, supporting Code 39 and Code 128 formats with a failure rate of less than 1%. The government will award the contract to the responsible quoter determined to be most advantageous based on a comparative evaluation of past performance, price, and technical capability. Pricing is based on a Cost per Patient Reportable Result (CPRR) model. Equipment acceptance is contingent upon the systems operating at an effectiveness level of 90% or more for 30 consecutive calendar days following installation. All quality control and calibration must adhere to Clinical and Laboratory Standards Institute (CLSI) guidelines, and waste characterization must comply with Code of Federal Regulations Title 40. Invoices are to be submitted electronically to the Austin Payment Center and paid in arrears upon inspection and acceptance.
Analytical Laboratory Instrument Manufacturing

POSTED

1 day ago

DEADLINE

in 22 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS