The Department of Veterans Affairs is conducting a market research effort through a sources sought notice to identify qualified Service-Disabled Veteran-Owned Small Businesses (SDVOSBs), Veteran-Owned Small Businesses (VOSBs), and Small Businesses (SBs) capable of providing an ophthalmic ultrasound system and related equipment for the Surgery Service at the C.W. Bill Young Veterans Medical Center in Bay Pines, Florida. This notice is not a solicitation but aims to gather information to determine if the requirement can be set aside for SDVOSBs or other socio-economic categories based on the responses received. If insufficient responses are obtained from SDVOSBs, the requirement could be opened to VOSBs, then to small businesses, or potentially to all interested parties. Interested vendors must submit capability statements and relevant documents by June 22, 2026. The requirement involves the procurement of an Ellex Absolu Ultrasound System or an equivalent product that meets specific technical specifications and compatibility requirements. The equipment must be a fully integrated ophthalmic ultrasound platform supporting multiple probe types, including 15 MHz, 20 MHz, and 50 MHz probes for detailed imaging of various ocular structures, as well as an A-scan biometry probe for cataract surgery planning. The system must allow seamless probe interchangeability, real-time high-resolution imaging, DICOM connectivity for image transfer, and include onsite installation, training, warranty, and technical support. The delivery package also includes accessories like the ultrasound cart, software licenses, and all necessary probes and cables for immediate clinical use. The solicitation number is 36C24826Q0806, and inquiries can be directed to the contract specialist at the Tampa office.
General Info
Agency
NAICS
Place of Performance
C.W. Bill Young Veterans Medical Center, Bay Pines, FL, 33744, USASet-Aside
Timeline
Response Deadline
Organization & Contact Information
Full Description
7. Salient Characteristics: Must be a fully integrated dedicated ophthalmic ultrasound platform capable of supporting posterior segment, anterior segment, and biometric ocular imaging from a single console without external third-party modules. Must support simultaneous compatibility with 15 MHz B-scan, 20 MHz annular B-scan, 50 MHz high-resolution linear probe, and A-scan biometry probes on one native manufacturer platform. Must allow plug-and-play probe interchangeability between all supported probes without requiring software reload, hardware adapter changes, or system reboot. Must provide a compact cart-mounted console configuration designed for movement between exam lanes and procedure rooms.
8.Imaging / Probe Requirements: 5. Must include a 15 MHz posterior segment B-scan probe optimized for retinal detachment, vitreous hemorrhage, tumor, and opaque media imaging. 6. Must include a 20 MHz annular probe utilizing concentric ring transducer to provide enhanced depth of field and high-detail ocular imaging. 7. Must include a 50 MHz linear high-resolution probe for ultrasound bio microscopy (UBM) and anterior segment imaging of cornea, iris, angle, ciliary body, and lens positioning. 8. Must provide real-time high-resolution imaging with freeze, cine review, caliper measurement, and image annotation functions. 9. Must provide image penetration through dense cataracts, corneal opacity, and vitreous hemorrhage.
9. Biometry Requirements: 10. Must include integrated A-scan biometry capability for axial length measurement and cataract surgery planning. 11. Must provide IOL calculation capability or exportable biometric data for lens power planning workflow.
10. IT / Network Requirements: 12. Must include native DICOM connectivity for image transfer to PACS/EMR systems. 13. Must support USB/network export of images and reports. 14. Must store patient exams on internal system database with searchable recall capability.
11. Accessories / Support: 15. Must include onsite installation, training, warranty, and OEM technical support. 16. Must include all probes, cables, cart, software licenses, and accessories required for immediate clinical use upon delivery.