Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on January 8, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6525--VerifEye Video Borescope

Awarded
36C24121Q0168Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334510
New
Federal
Hearing Aid Fitting and Verification for Shiprock Service Unit (IEE or ISBEE Set Aside)
Solicitation # SS-SRSU-27-0003
The Indian Health Service Shiprock Service Unit is conducting market research through a sources-sought notice to identify capable Indian-owned economic enterprises, both large and small, to provide hearing aid fitting and verification services. The primary objective is to reduce hearing aid rejection and costly remakes while ensuring patients receive optimal benefit from their devices. The requirement includes the provision of equipment with advanced technical specifications, such as dual ear capability, a frequency range of 200 to 16,000 Hz, and a comprehensive test suite including speechmap counseling and pediatric probe tube placement. Additionally, the selected vendor must provide installation and training for the Audiology Department. This opportunity is categorized under NAICS code 334510 for electronic hearing aid manufacturing. In accordance with the Buy Indian Act, the government will prioritize responses from Indian-owned economic enterprises before considering other small business set-aside programs. Interested parties must be registered in the System for Award Management and submit a company profile, a capability statement, and a completed IHS IEE Representation Form by November 03, 2026. This notice is for market research purposes only and does not constitute a formal solicitation.
Navajo Area Indian Health Svc

POSTED

2 days ago

DEADLINE

in 4 days
NAICS: 334510
New
Federal
Ocular Scanner
Solicitation # W91CRB-26-AWSP-Scanner-Ultrasonic-Ocular-RPP
The Portfolio Acquisition Executive Maneuver Ground Project Manager Maneuver Medical Systems is soliciting prototype proposals for a Scanner Ultrasonic Ocular device under Other Transaction Authority pursuant to 10 U.S.C. 4022. The objective is to award two prototype agreements for the delivery and demonstration of FDA-approved commercial solutions that provide anatomical visualization and diagnostic imaging of the eye, specifically for the anterior and posterior segments. Awardees are required to deliver four prototype units within 45 to 60 days of award for operational and environmental testing conducted in accordance with MIL-STD-810H. The estimated period of performance is twelve months, with awards expected around the first quarter of fiscal year 2027. The procurement utilizes a comparative best-value methodology, prioritizing technical approach, performance compliance, reliability, schedule realism, and past performance over cost. Key requirements include Trade Agreements Act compliance, MIL-STD-130N marking for hardware, and the provision of ruggedized transport cases. Deliverables encompass the hardware units, comprehensive user and maintenance manuals, cybersecurity documentation, and on-site operator training. Proposals must be submitted as four separate PDF volumes via DoD SAFE or secure email by November 12, 2026. This action is a direct Other Transaction Agreement and is not subject to the Federal Acquisition Regulation or Defense Federal Acquisition Regulation Supplement.
W6QK Acc-Apg

POSTED

3 days ago

DEADLINE

in 13 days

General Info

Contract Value

$46,925

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing

Place of Performance

ME, 02132

Set-Aside

NONE

Award Issued Date

Documents

1

36C24121Q0168.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseAwarded
Posted

Sources Sought

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)
Contacts1 person available
OfficeTOGUS, ME, 04330, USA
Office AddressTOGUS, ME, 04330, USA
Contacts
Divianna MathurinContract Specialist

Full Description

Show more
Rev:103019 - STERIS Instrument Management Services, Inc. 3316 2nd Avenue North, Birmingham, AL 35222, +1 (555) 000-0000, contact@example.gov Distributed by STERIS IMS STATEMENT OF WORK Sterile Processing Service under Boston Healthcare System is need of 5 Borescope. 2 Jamaica Plain, 2 for West Bury and one for Brockton. Instructions for Use Product Name VerifEyeTM Camera Control Unit (CCU) and Inspection Unit Type of product Borescope system Product numbers VEYE101-101 VerifEyeTM Inspection Unit VEYE101-102 VerifEyeTM Inspection Unit (Brand New Repair/Exchange) VEYE101-112 VerifEyeTM Inspection Unit 1.2m VEYE101-113 VerifEyeTM Inspection Unit 1.2m (Brand New Repair/Exchange) VEYE101-103 VerifEyeTM Camera Control Unit (CCU) Intended use Assist in visual inspection of medical device cannulas and lumens. Range of applications Medical instruments and devices that require visual inspection by providing illumination, magnification and optional documentation in channels and lumens that are not visible to the unaided eye. Product Specifications Overall length of borescope: Working length: 1.9m (VEYE101-101, VEYE101-102), 1.2m (VEYE101-112, VEYE101-113) Distal camera diameter: 1.6mm Max Weight: Inspection Unit 0.3125 lbs. (141.75 g), CCU 1.3125 lbs. (595.34 g) Resolution: 400 x 400 pixels Brightness control: To increase or decrease illumination Optical angle of view: 120 degrees Connections: HDMI Out x 1, USB3.0 x 1, DC In x 1 VEYE101-101, VEYE101-112 VerifEyeTM Inspection Unit IP rating: IPx7 VEYE101-102, VEYE101-113 VerifEyeTM Inspection Unit (New Repair/Exchange) IP rating: IPx7 VEYE101-103 VerifEyeTM Camera Control Unit (CCU) IP rating: IPx4 Image capture: Via USB3.0 and VerifEyeTM viewer Video clip recording: Via USB3.0 and VerifEyeTM viewer Package contents Camera Control Unit Diagrams Connector to Illumination Inspection Unit control USB 3.0 port Power switch Power adapter HDMI output connector Inspection Unit Diagrams Flexible insertion tube CCU Cable ¼-20 Mounting hole Shipping and Storage Shipping requirements Inspection Unit and CCU should be shipped in original packaging. Storage requirements -18 degrees C to 60 degrees C, 15% to 90% relative humidity. Packing conditions Inspection Unit and CCU should be packed in original foam packaging and protective coil. Protective coil is for shipping purposes and long- term storage only and not for use as a daily storage solution. Instructions for Use Description of Use(s) Assist in visual inspection of medical device cannulas and lumens. Preparation for Use Before connecting the Inspection Unit, verify that the VerifEye viewer software is installed (if optional tablet was purchased) by clicking on Windows>All Programs>VerifEye. VerifEye viewer software can only be installed on a tablet purchased from STERIS IMS. If the VerifEye viewer software is not installed, contact STERIS IMS for support. Inspection prior to use Inspection of the Inspection Unit should be performed prior to each use. Inspect the Inspection Unit head for cracks. Inspect the Inspection Unit insertion tube for kinks and illumination performance. Inspect the video image by powering on the unit prior to insertion into the device that is being inspected. If any damage is noted to any part of the Inspection Unit, discontinue use immediately and contact STERIS IMS for service. Operation 1. Mount the Inspection Unit onto a mounting fixture using the ¼-20 mounting hole (if optional stand was purchased). 2. Connect the HDMI output from the CCU to an HDMI display (if using an HDMI monitor). 3. Connect the USB3.0 from the CCU to a USB3.0 port on a Windows PC using a USB3.0 cable (if using the optional tablet and VerifEye viewer software). 4. Connect the DC power input on the CCU to an AC power plug using the included power adapter. 5. Remove the connector cable cap and connect the Inspection Unit to the CCU by inserting the metal connector on the Inspection Unit cable into the CCU Camera Input. 6. Power on the Inspection Unit by turning the power switch to the ON (I) position. 7. Verify a live image is displayed on the HDMI monitor (if connected) or on the optional tablet using the VerifEye software. 8. Adjust the illumination level by rotating the brightness control knob (clockwise to increase illumination, counter clockwise to decrease illumination). 9. Grasp the Inspection Unit near the flexible distal end and gently insert into the intended device. Take care not to bend or kink the flexible distal portion. Operation for VerifEye Touchscreen with Live Viewing software (tablet) The following instructions apply to the optional tablet with the viewer software installed. Before launching the VerifEye Viewer, check that all connections are properly connected. Power adapter to tablet USB 3.0 cable between CCU and tablet Power on the tablet by pressing the tablet On/Off button. Sign on to the Steris login by clicking Sign In. Power on the CCU by turning on the power switch located on the rear of the CCU. Launch the VerifEye viewer by double clicking on the VerifEye Viewer icon on the desktop. The live camera image will appear in the viewing window of the software. To change the default directory for saving images and video clips, click the Folder button in the viewer software. To capture an image, click the Snapshot button. 9. To capture a video clip, click the Record button. To stop recording, click the Stop Record button. To play back recorded video, click the Play button. After clicking the play back window, select the video file you want to playback. The playback window will open. The playback window has several controls including: Rewind Slow motion mode Snapshot Delete file Previous file Close Zoom in Zoom out Zoom 1:1 Cleaning and Maintenance Cleaning Regarding the cleaning and disinfection of the VerifEye Video Borescope Inspection Unit (VEYE101- 101/VEYE101-102/VEYE101- 112/VEYE101-113) the VerifEye Video CCU (VEYE101-103) and related accessories, it is up to the end user to determine when to clean, disinfect and/or do both based on the facility s protocol. VEYE101-101/102/112/113 VerifEyeTM Inspection Unit Wipe off any gross soil and wipe down with enzymatic solution, such as Prolystica® HP Neutral or Prolystica® 2X Concentrate Neutral Detergents, after every use. Rinse under clean water. The Inspection Unit can be submerged with the secure cap. Inspection Unit IP rating: IPx7. Follow the disinfectant manufacturers IFU for use with scopes. Dry with clean, lint-free towel. VEYE101-103 VerifEyeTM Camera Control Unit (CCU) Wipe down with moist antibacterial wipes according to OEM IFU for contact time. DO NOT submerge this unit. Dry with clean, lint-free towel. CCU IP rating: IPx4 Tablet The tablet can be sanitized by using one of the following recommended solutions PDI Sani-Cloth Plus, CaviWipes, Covidien Alcohol Prep Pads, any similar wipes with IPA (Isopropyl Alcohol) solution under 70%, Total Solutions Full Spectrum Disinfectant Wipes, or Clorox Healthcare Bleach Germicidal Wipes--without risk of damaging the device. HDMI Cable Wipe down with moist antibacterial wipes according to OEM IFU for contact time, paying careful attention not to get the cable contacts wet. DO NOT submerge this unit. Dry with clean, lint-free towel. USB3.0 Cable Wipe down with moist antibacterial wipes according to OEM IFU for contact time, paying careful attention not to get the cable contacts wet. DO NOT submerge this unit. Dry with clean, lint-free towel. Power adapter Wipe down with moist antibacterial wipes according to OEM IFU for contact time, paying careful attention not to get the cable contacts wet. DO NOT submerge this unit. Dry with clean, lint-free towel. Stand Wipe down with moist antibacterial wipes according to OEM IFU for contact time. Dry with clean, lint-free towel. Disinfection of VEYE101-101/102/112/113 VerifEyeTM Inspection Unit Wipe down with moist antibacterial wipes according to OEM IFU for contact time. The Inspection Unit can be submerged with the secure cap. Inspection Unit IP rating: IPx7. Follow the disinfectant manufacturers IFU for use with scopes. Dry with clean, lint-free towel. Sterilization of VEYE101-101/102/112/113 VerifEyeTM Inspection Unit Validated in STERIS V-PRO maX/maX2 Low Temp Sterilization System. Validated in STERIS SYSTEM 1E Liquid Chemical Sterilant System. Follow the OEM IFU for sterilization settings and cycle time. Disinfection of VEYE101-103 VerifEyeTM Camera Control Unit (CCU) Wipe down with moist antibacterial wipes according to OEM IFU for contact time. DO NOT submerge this unit. Dry with clean, lint-free towel. Maintenance The VerifEyeTM Camera Control Unit (CCU) and Inspection Unit and all components are designed as non-user serviceable parts and components. For service, please contact your STERIS IMS representative or call +1 (555) 000-0000. Storage Store the VerifEyeTM Camera Control Unit (CCU) and Inspection Unit in a dry environment with a temperature of no higher than 60 degrees C or no lower than -20 degrees C. Store the Inspection Unit loosely coiled in the designated storage container or in a way that the insertion portion won't be damaged. Special Warnings and Cautions Do not modify or disassemble the unit. Do not subject the distal end of the Inspection Unit to impact or bending, which may cause damage to the CMOS camera located at the distal tip. Do not tightly coil or kink the insertion portion of the unit. Do not allow the CCU to come in contact with excessive amount of water. This may cause damage to the CCU or electrical shock. CCU IP rating: IPx4. Do not set any equipment on the Inspection Unit. FCC information This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. VerifEyeTM Camera Control Unit (CCU) and Inspection Unit is CE Marked Service For service, please contact your STERIS IMS representative, call 800- 783-9251, or email contact@example.gov . Warranty The VEYE101-101/102/112/113 VerifEyeTM Inspection Unit carries a 365 day warranty against defects for parts and labor. The VEYE101- 103 VerifEyeTM Camera Control Unit (CCU) carries a 365-day warranty against defects for parts and labor. Lifetime The lifetime of VerifEyeTM Camera Control Unit (CCU) and Inspection Unit is determined by their adequate functionality and careful care during use. End of lifetime is determined by wear and damage due to the use. Improperly functioning, damaged, or excessively worn VerifEyeTM Camera Control Unit (CCU) and Inspection Unit should not be used. VerifEyeTM Camera Control Unit (CCU) and Inspection Unit are distributed by STERIS IMS. VerifEye is a trademark of STERIS Instrument Management Services (IMS). Prolystica is a registered trademark of STERIS Corporation.

More opportunities from Department Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)

Same awarding agency

NAICS: 532490
New
Federal
W038--Rental & Support Services for Wheeled Loaders w/3yard bucket
Solicitation # 36C24126Q0815
The Department of Veterans Affairs VA Maine Healthcare System Togus is soliciting quotes for the rental and support of two wheeled loaders equipped with 3-yard buckets and Fusion couplers. The equipment will be used for snow removal from parking lots at the Togus VAMC campus, with an anticipated start date of November 9, 2026. The rental is on a month-to-month basis for an undetermined duration, estimated between one and six months. Each loader must meet or exceed specifications comparable to CAT 926 or CAT 930 models, featuring 160 to 170 hp Tier 4 Final engines, ROPS/FOPS certified cabs with climate control, and four liquid-filled tires for added weight. The selected contractor must provide comprehensive 24/7 service and support, including all preventive maintenance and repairs. Repairs must be initiated within 24 hours of notification, or a replacement loader must be provided at no additional cost. This procurement is a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 532490. Award will be made to the technically acceptable vendor offering the lowest evaluated price, based on an evaluation of technical capability, past performance, and total price. Quotes must include a monthly rental rate and itemized delivery and pickup charges, with a submission deadline of November 2, 2026.
Other Commercial and Industrial Machinery and Equipment Rental and Leasing

POSTED

1 day ago

DEADLINE

in 4 days
View Details
NAICS: 238990
New
Federal
Amendment 0001- Replacement-in-Kind Repair of Existing Perimeter Security Fence (Ameristar Impasse Trident) Brand Name or Equal
Solicitation # 36C24127Q0041
The Department of Veterans Affairs VA Boston Healthcare System is soliciting quotes for a firm-fixed-price contract to perform a localized replacement-in-kind repair of the perimeter security fence at the Brockton VA Campus in Brockton, Massachusetts. The project focuses on restoring five affected fence bays and six associated post locations that were damaged by winter snow-removal activities. The benchmark product is the Ameristar Impasse Trident system, and any proposed equal must meet all salient characteristics, including the use of corrosion-resistant, tamper-resistant hardware and a uniform transition in profile, color, and finish to the existing fence. The scope is strictly limited to the damaged sections and does not authorize any redesign or expansion of the perimeter. This procurement is a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The period of performance is scheduled from December 1, 2026, to January 31, 2027. Award will be made to the responsible offeror determined to be most advantageous based on price, past performance, and technical capabilities. Proposals must be submitted in three separate PDF volumes covering technical approach, past performance, and pricing. Following Amendment 0001, a site visit is scheduled for November 10, 2026, and the closing date for the receipt of offers has been extended to November 13, 2026, at 1:00 PM EST.
All Other Specialty Trade Contractors

POSTED

1 day ago

DEADLINE

in 14 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS