Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Veterans Affairs was posted on March 23, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6530--PATIENT TRANSFER CEILING LIFT (VA-21-00026609)

Awarded
36C25521Q0128Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Contract Value

$279,073.5

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

KS

Set-Aside

NONE

Award Issued Date

Documents

3
DOCX
PDF
PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseAwarded
Posted

Sources Sought

Type Changed

Sources Sought → Solicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Contacts1 person available
OfficeLEAVENWORTH, KS, 66048, USA
Office AddressLEAVENWORTH, KS, 66048, USA
Contacts
MICHAEL P MURPHYCONTRACT SPECIALIST

Full Description

Show more
This Sources Sought Notice is for planning purposes only and shall not be considered as an invitation for bid, request for quotation, request for proposal, or as an obligation on the part of the Government to acquire any products or services. Your response to this Sources Sought Notice will be treated as information only. No entitlement to payment of direct or indirect costs or charges by the Government will arise as a result of contractor submission of responses to this announcement or the Government use of such information. This request does not constitute a solicitation for proposals or the authority to enter into negotiations to award a contract. No funds have been authorized, appropriated, or received for this effort. The information provided may be used by the Department of Veterans Affairs in developing its acquisition approach, statement of work/statement of objectives and performance specifications. Interested parties are responsible for adequately marking proprietary or competition sensitive information contained in their response. The Government does not intend to award a contract on the basis of this Sources Sought Notice or to otherwise pay for the information submitted in response to this Sources Sought Notice. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the services described below. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) company name (b) address (c) point of contact (d) phone, fax, and email (e) DUNS number (f) Cage Code (g) Tax ID Number (h) Type of small business, e.g. Services Disabled Veteran Owned small Business, Veteran-owned small business, 8(a), HUBZone, Women Owned Small Business, Small disadvantaged business, or Small Business HUBZone business and (i) must provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor for the work described below. The VA Heartland Network 15, Contracting Office located at 3450 South 4th Street, Leavenworth, KS, 66048-5055 is seeking a potential qualified contractor to provide all labor, supervision and all other resources required to deliver the requirements stated herein, except as may otherwise be specified in this statement of work. Guldmann lifts, as noted in the location list (with fast motion, continuous-charge room-covering rail systems, integrated scales with readouts in the hand control, and tool-free emergency lowering) are to be delivered, installed, and tested at the Harry S. Truman Memorial Veterans Hospital located at 800 Hospital Drive, Columbia, MO 65201. Statement of Work: Ceiling lifts in HSTMVA, Columbia, Missouri ****Please Note: This is a Brand Name Only Procurement. Due to existing equipment currently in use, products not manufactured by the OEM Guldmann will not be considered. Due to safety, compatibility, and liability concerns, the facility will not consider mixing or adding non-OEM parts/equipment to the existing system. **** General Information Title of Project: Ceiling lifts in HSTMVA, replacement of end of life lifts and new lifts in specialty areas Scope of Work: The contractor shall provide all labor, supervision and all other resources required to deliver the requirements stated herein, except as may otherwise be specified in this statement of work. 770-pound advanced ceiling lifts, as noted in the location list (with fast motion, continuous-charge room-covering rail systems, integrated scales with readouts in the hand control, and tool-free emergency lowering) are to be delivered, installed, and tested. If proposed cost exceeds budget, HSTMVA will prioritize and specify final lift locations. Background: Ceiling lifts have been installed in many places throughout HSTMVA. These requested systems integrate into an existing system of 100% Guldmann lifts that are used to lift, transfer, and reposition inpatients and outpatients. Patients may arrive at any of these locations on a sling or be sent on to another location on a sling applied at these locations. Some of the systems being requested are filling in gaps where patients still need to be lifted, transferred, or repositioned. Many are being installed in areas that already contain similar equipment. Performance Period/Schedule: The contractor shall complete the work required under this SOW in 365 calendar days or less from date of award, unless otherwise directed by the Contracting Officer (CO). If the contractor proposes an earlier completion date, and the Government accepts the contractor s proposal, the contractor s proposed completion date shall prevail. Installation dates must be coordinated with COTR as some require previous work, and dates may be adjusted by the Government as required if engineering changes are required and delayed. General Requirements Contractor will provide evaluation of spaces where ceiling lifts are needed and submission of plans to HSTMVA Engineering service, to assure that workable versions are installed and comply with VA design requirements and relevant standards. A walkthrough is required. Contractor will coordinate with Engineering service to verify access to engineering mechanical, HVAC, and fire systems components within the mounting area of the lift units. Contractor will coordinate with Contracting Officer Technical Representative (COTR) to schedule installations in individual areas. Contractor will provide information on minimum clearances for operation of each lift. Contractor will provide a list of all construction or modifications required to install these lifts. The goal is to install around any obstructions without requiring VA to make construction modifications. Contractor will provide all qualified personnel, materials, equipment and services necessary to install ceiling lifts and supporting electrical outlets for the rooms described below under Location, including lifts, tracks, spreader bars, attachment hardware, and all other equipment necessary for safe operation. Detailed requirements are described in the Standards and Special Requirements sections. Lift systems may be configured in any way that covers the rooms best and meets the requirements. Contractor will provide installation and testing of all equipment for ceiling lifts according to VA checklist requirements, resulting in a turnkey system. Contractor will provide training on equipment use for all equipment included in coordination with COTR. Contractor will provide evidence of testing of all lift systems provided and schedule testing when it can be overseen by COTR. C. Standards: Ceiling Lift Performance Requirements: Ceiling lift manufacturer must allow and warrant the use of their lifts with the full range of Guldmann loop slings. The rail system must allow for continuous charging of the lift motor by recharging at any location on the rail. The lifts shall be mounted (using ceiling, wall, or floor support as determined by building structure and room covering layout needs) to provide lifting capability for the maximum area possible within each room which means wall to wall not just over the bed. Lifts must be capable of picking patients up off the floor. Contractor must install lifts without relocating or interfering with operations of existing sprinkler heads, lights, HVAC grills, curtain tracks, IV tracks, televisions, permanent furniture, or other permanent structure. Contractor must describe any such fixtures that must be moved during contract bid and pre-construction meetings. Installation may be delayed, canceled, or moved to a mutually acceptable location if building changes cannot be made in ways that allow lift installation. Contractor shall not breach any firewalls during installation of these lifts. Any fire barrier that must be penetrated must be discussed with VA safety personnel and must immediately have fire barrier repaired. Each room where lifts are installed shall be returned to original condition, excluding the newly installed ceiling lift. Ceilings must not be slotted exposing space above ceiling to the room below. Ceiling lift motors shall be capable of lifting at least 770 pounds when stated above, and 825 pounds where stated above. Integrated scales must be built into the lifts, using the same controller and the same power source as the lift. The scale must not make the hanger bar extend any lower than it would without the scale present. The scale must be readable without looking up above the patient; a display on the controller is acceptable. A specific opportunity for Service Agreements, Preventive Maintenance Agreements, and Extended Warranty Agreements should be presented. Warranty shall include all travel or shipping associated with any warranty repair. Motors shall be GFCI protected and the entire system shall be UL certified. Ceiling lifts must be motorized. Ceiling lifts must include a hanger bar suitable and allowable for use with the full range of Guldmann slings. Ceiling lifts must recharge automatically, by recharging at any location on the rail. Lifts that recharge without employee action will be preferred. Ceiling lifts must include safeguards to prevent patients from being trapped or hurt, such as emergency stop buttons or emergency lowering devices in case of power failure. Use of emergency lowering devices must not require tools or ladders. Contractor shall provide the following with the bid: Provide proof of multiple ceiling lift installations of the room covering style with minimum 10 x12 coverage in this or other Veterans Administration Hospitals. Provide proof of ongoing service quality and consistent management, including failure reports and any other applicable documentation. Training: Contractor shall provide certified in-service training for Safe Patient Handling Coordinator, Unit Peer Leaders, and direct patient care staff as requested by SPH Coordinator for all shifts at no additional cost to the Government, for any equipment new to this facility. This training must include competency verification. Training must include each new type of equipment and sling used in an area. Manuals: Contractor shall provide electronic copies of the user manuals and repair manuals for each different model of lift installed under this order or contract at no additional cost to the government. Inspection: Each room s lift system shall be weight tested after installation and photographed for compliance, with an authorized facility representative from Safety or Engineering present completing the remainder of the installation checklist. Each weight test sheet shall be provided to Contracting Officer Technical Representative. Any changes in inspection requirements during the period of installation will be communicated to the Contractor immediately. Documentation supplied to the facility of the inspection must include the following: Compliance with manufacturer s clearance requirements. Model and serial numbers of lifts installed. Confirm receipt of operator and maintenance manuals. Verification of proper connections of structural system to the building s structure. Verification of proper structural component sizing and physical installation to make sure that proper structural system and size is in place and properly installed to support the lift. Verification of proper interface of lift unit at ceiling (hard deck or soft tile) or wall/floor, and proper installation of all protective features around the support rods and rails/tracks. Inspection of lift motor casing for cracks and alignment. Full extension and inspection of lift strap for loose threads or frays. Inspection of spreader bar and clips for cracks and for loose or missing rings or cotter pins. Verification that all rail end stops are in place and tightened. Inspection and activation of hand control for full operation (e.g., up, down, left, right) and any return to charge function or continuous charging operation. Inspection and activation of emergency up/down motor case control buttons. Confirm any and all motor case indicator lights are functioning (e.g., red service warning light, charging state light) If included in installation, verify rail turntable function, exchanger function, and gate alignment. Confirm track is clean and clear of all debris (suggest wiping entire length of interior track channel with a soft cloth). Verification of any soft start or soft stop features and that lifting speed does not exceed 2.5 inches per second with zero load. Verification of load testing and deflection testing at lift listed maximum for each lift unit at its maximum rated lift capacity. Conduct this test in three progressive stages starting with a 100 lbs load, then 50% of maximum rated lift capacity, then 100% of maximum rated lift capacity. This test must be done with proper precautions and/or personal protective equipment. Verification of any soft start or soft stop features and that lifting speed does not exceed 1.5 inches per second under maximum rated lift capacity Verification of function of emergency stop at maximum rated lift capacity. Verification of emergency lowering feature at maximum rated lift capacity. Contractor conduct requirements: All employees and subcontractors must wear a visible name and company identification when onsite. When more than one person is onsite performing work under this contract, one must be designated as a supervisor and must be fully responsible for the work to be performed. The Contractor shall provide all supplies, materials, equipment, qualified personnel, supervision, management, and transportation to perform all tasks as identified herein. All work is to be performed in accordance with the guidelines established by Federal, State, and local ordinances and The Joint Commission. The Contractor s procedures and quality control procedures shall conform to these guidelines. Contractor personnel must conduct their work so as not to interfere with the normal functioning of the facility and will stop work if asked by HSTMVA. Hours of work may need to be limited to daytime on units where patients sleep and night time in areas where patients would be exposed by daytime work. The Contractor shall take all precautions necessary to protect the lives and health of occupants of the building. The Contractor must follow procedures required by HSTMVA Infection Control personnel and the construction safety committee, to include any required dust control. The Contractor must state what efforts will be made to minimize noise during installation of equipment. The Contractor shall immediately correct any fire and safety deficiencies caused by his personnel. If the contractor fails or refuses to correct deficiencies promptly, the Contracting Officer may issue an order stopping all or any part of the work and may hold the contractor in default of the contract. The Contractor shall comply with applicable Federal, State, and local safety and fire regulations and codes which are in effect at the beginning of the contract period. The contractor shall keep abreast of any changes in these regulations and codes applicable to the contract. All material and equipment will be removed from the facility or stored properly at the end of each work day and secured during the work day in the areas specified by the Contracting Officer s Technical Representative. The Contractor is responsible for supplying, completing, and submitting all reports required or requested by Federal, State, or local ordinances which pertain to any duties contained in the contract. The Contractor will be required to furnish HSTMVA with material safety data sheets for all chemicals used during installation. This information is required by the VA for emergency treatment in the event of ingestion of and/or contact with the material by humans and is required by OSHA regulations. The contractor shall furnish at his own expense all labor, materials, machinery, and appliances which may be necessary or appropriate in the performance of this contract. All accumulated rubbish is to be collected and placed in the dumpster provided by the Government. Special Requirements: The contractor must have visited the sites and assessed the structure of each ceiling lift location to ensure safe installation of the equipment and shall supply the installation plans to HSTMVA Engineering Service and Construction Safety Group, who must accept them before installation. The contractor should not require movement of any lights, sprinklers, televisions, or other fixtures in order to install ceiling lifts. If movement of preexisting fixtures is unavoidable, the contractor must include such notice when the bid is submitted. Wall mounted lifts are acceptable in the place of ceiling mounts where they are more effective or cause less risk to install. Ceiling lifts must not add obstacles or impair any normal operations in patient care rooms. The Contractor shall install all wiring subsequent to the outlets necessary for complete function of ceiling lifts. The contractor will install all necessary mounts, braces, and any other components needed for full lift function and safety. Schedule for Deliverables: If for any reason any deliverable cannot be delivered within the scheduled time frame, the contractor is required to explain why in writing to the CO, including a firm commitment of when the work shall be completed. This notice to the CO shall cite the reasons for the delay, and the impact on the overall project. The CO will then review the facts and issue a response, in accordance with applicable regulations. Changes to Statement of Work: Any changes to this SOW shall be authorized and approved only through written correspondence from the CO. A copy of each change will be kept in a project folder along with all other products of the project. Costs incurred by the contractor through the actions of parties other than the CO shall be borne by the contractor. Reporting Requirements: No reports are necessary, but the lift test sheets must be provided to the COTR by 2 weeks after installation. Lift installation is not considered complete and cannot be paid for until the lift test is complete and provided to the COTR. Government Responsibilities: HSTMVA will provide: Guidance for contractor site visits and information on which rooms need lifts. Coordination to allow for lift installation as rooms are available. Technical information on the building and requirements for construction. Coordination and scheduling for training efforts. Answers to Contractor questions during the purchasing and installation process. Prioritization and final specification of lift locations in case proposed cost exceeds budget. Important information: The Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this sources sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Currently a total set-aside for Service-Disabled Veteran Owned Small Business firms is anticipated based on the Veterans Administration requirement with Public Law 109-461, Section 8127 Veterans Benefit Act. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set-aside or full and open competition may be determined. The North American Classification System (NAICS) code for this acquisition is 339113 ( Surgical Appliance and Supplies Manufacturing). The small business size standard is 1,000 employees. Notice to potential offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM located on the web at www.sam.gov). Additionally, all Service-Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be registered with the Department of Veterans Affairs Center for Veterans Enterprise VetBiz Registry located at http://vip.vetbiz.gov. All interested Offerors should submit information by e-mail: to contact@example.gov. All information submissions should be received no later than 15:00 PM CST on Friday February 5, 2021. After review of the responses to this announcement, the Government intends to proceed with the acquisition and a subsequent solicitation will be published.

More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)

Same awarding agency

NAICS: 524292
New
Federal
Q517--PHARMACY BENEFITS SERVICES | WICHITA |
Solicitation # 36C25527Q0015
The Department of Veterans Affairs, Network Contracting Office 15, is soliciting quotations to establish a single-award, Indefinite Delivery/Indefinite Quantity (IDIQ) contract with fixed unit pricing for Pharmacy Benefit Services. This contract supports the First Fill Prescription Voucher Program at the Robert J. Dole VA Medical Center in Wichita, Kansas, including its associated Community Based Outpatient Clinics and Home-Based Primary Care programs. The program is designed to provide eligible Veterans with first or urgent fill prescriptions, typically limited to a 10-day supply or 14 days for antibiotics, in scenarios where VA pharmacies are impractical, such as after telehealth appointments or emergency room visits. The period of performance is scheduled from January 4, 2027, to January 3, 2030. This procurement is a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), and all offerors must be registered in the SBA VetCert database to be considered. The selected contractor must maintain a geographically accessible pharmacy network with 24-hour and extended holiday coverage, adhere to VA-provided emergency medication formulary lists, and maintain strict HIPAA and Privacy Act compliance. Award will be based on best value, with technical capability and past performance combined being weighted more heavily than price. Quotations must include a dispensing fee per prescription, a discount from the Average Wholesale Price, and an administration fee per prescription, and must be submitted electronically to the contracting officer by November 23, 2026.
Pharmacy Benefit Management and Other Third Party Administration of Insurance and Pension Funds

POSTED

2 days ago

DEADLINE

in 23 days
View Details
NAICS: 238210
New
Federal
657A5-26-111, Triennial Electrical Testing
Solicitation # 36C25526R0186
Solicitation 36C25526R0186 is a negotiated, fixed-price construction contract issued by the Department of Veterans Affairs for triennial electrical testing at the Marion VA Medical Center in Illinois. This project is a total set-aside for Service-Disabled Veteran Owned Small Businesses (SDVOSB) under NAICS code 238210, with an estimated construction magnitude between 500,000 and 1,000,000 dollars. The scope of work involves the maintenance, inspection, adjustment, and testing of the Electrical Power Distribution System, including approximately 325 electrical panels, 135 transformers, 220 switches, 6 generators, and 25 automatic transfer switches. All work must adhere to NETA 2019 specifications, the latest National Electrical Code, VHA Directive 1028, and NFPA 99 and 110 standards. The contract will be awarded based on the Lowest Price Technically Acceptable (LPTA) process, evaluating five key factors: prime contractor past performance, technical construction and electrical testing experience of the prime, technical experience of the electrical subcontractor, qualifications of proposed staffing, and the prime contractor's safety plan. Performance must begin within 10 calendar days of the notice to proceed and be completed within 90 calendar days. Required deliverables include maintenance and testing reports and a schedule of costs submitted within 14 days of award. Proposals must be submitted in three separate volumes covering technical details, pricing via SF 1442, and a bid bond. Additional requirements include compliance with the Davis-Bacon Act, Buy American requirements, and the submission of an electronic security memorandum to maintain the confidentiality of sensitive information.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

2 days ago

DEADLINE

in 9 days
View Details
NAICS: 561730
New
Federal
S208--Grounds Maintenance Services for the St. Louis VA Medical Center Jefferson Barracks
Solicitation # 36C25527Q0023
Solicitation 36C25527Q0023 is a request for quotation for routine and emergency grounds maintenance services at the 126.65-acre St. Louis VA Medical Center Jefferson Barracks campus. This five-year IDIQ contract, running from November 16, 2026, to November 15, 2031, has a guaranteed minimum of $2,500 and a maximum life-of-contract value of $950,000. The scope of work includes weekly mowing to a height of 3.5 to 4.5 inches, vertical edging, debris removal, and seasonal fertilizer, seed, and pest treatments. Performance is monitored through a Quality Assurance Surveillance Plan involving random and biweekly inspections to ensure the grounds remain clean, safe, and aesthetically pleasing. The procurement is issued as a tiered set-aside, prioritizing Service-Disabled Veteran-Owned Small Businesses (Tier 1), followed by Veteran-Owned Small Businesses (Tier 2), and other small businesses including HUBZone, 8(a), and women-owned concerns (Tier 3). Award will be based on the best benefit to the government, evaluating experience, technical approach, and price. Technical requirements include the provision of a Quality Control Plan within 21 days of award, a four-hour emergency response time, and mandatory OSHA 10-Hour Construction Safety training for all onsite personnel. Contractors must also maintain a State of Missouri commercial applicator license for pesticide and herbicide use and meet specific general liability, automobile, and workers compensation insurance minimums.
Landscaping Services

POSTED

2 days ago

DEADLINE

in 5 days
View Details
NAICS: 541350
New
Federal
H112--Annual/Sem-i annual fire smoke inspections and auto door services l EKH
Solicitation # 36C25526Q0617
Solicitation 36C25526Q0617 is a request for quotations for an Indefinite-Delivery, Indefinite-Quantity (IDIQ) firm-fixed-price contract to provide inspection, preventive maintenance, and repair services for fire-rated, smoke-rated, and automatic door systems at the Dwight D. Eisenhower VA Medical Center in Leavenworth, Kansas. This total small business set-aside under NAICS 541350 covers approximately 126 manual fire/smoke door assemblies and 57 automatic doors. The contract consists of a 12-month base period and four option periods, with a total ceiling of 750,000 dollars. Key requirements include semiannual inspections conducted according to NFPA 80, NFPA 101, NFPA 105, and AAADM standards, as well as on-call repair services with strict emergency response times requiring a callback within one hour and on-site arrival within four hours for life-safety emergencies. The quotation deadline has been extended to November 10, 2026, at 3:00 p.m. CST, with submissions sent via email to Michael P. Murphy. Offerors must submit two separate volumes: a Technical Capability volume covering approach, AAADM-certified personnel, and healthcare experience, and a Price volume including a completed price schedule for all five ordering periods. Award will be based on the most advantageous offer, evaluating technical capability, past performance, and veterans involvement alongside price. Technical capability is the most important non-price factor, and a rating of unacceptable in this category renders a quote ineligible for award. All work must adhere to strict safety and security protocols, including Infection Control Risk Assessment (ICRA) and the protection of VA sensitive information.
Building Inspection Services

POSTED

2 days ago

DEADLINE

in 10 days
View Details
NAICS: 621511
New
Federal
Q301--New Reference Lab Testing | Legacy VISN 15
Solicitation # 36C25526R0066_1
The Department of Veterans Affairs, through Network Contracting Office 15, is soliciting proposals for referral laboratory services to support VISN 4, HSA 4.2 (Legacy VISN 15) across various medical and health care centers in Missouri, Kansas, and Indiana. The contractor will be responsible for the transportation of clinical specimens, pre-analytical processing, analytical testing based on a reference test manual, and the reporting of results. The scope includes providing all necessary personnel, equipment, and supplies, such as requisition forms and specimen collection materials, at no charge. The contract is structured with a one-year base period starting January 1, 2027, and four subsequent one-year option periods. Award will be based on the most advantageous offer, where technical capability and past performance are significantly more important than price. Evaluation factors include test analysis and processing, quality assurance, and IT connectivity for electronic transmission of results. The contractor must adhere to strict quality standards, including specific limits on modified test results, courier pickup failures, and turnaround time delays. Compliance with HIPAA, VA Cybersecurity Program directives, and hazardous material shipping regulations under 49 CFR is mandatory. Proposals are due by December 4, 2026, and must be submitted in two separate parts: a price response and a non-price response containing required certifications and technical documentation.
Medical Laboratories

POSTED

2 days ago

DEADLINE

in about 1 month
View Details
NAICS: 236220
New
Federal
Z2DA--657-27-103JB, FCA Replace Building 51 Roof, JB
Solicitation # 36C25527Q0044
The Department of Veterans Affairs, Network Contracting Office 15, is conducting market research through a Sources Sought Notice to determine the availability of qualified Service-Disabled Veteran-Owned Small Business (SDVOSB) firms for a construction project at the St. Louis Medical Center Jefferson Barracks. The project involves the replacement of the roof and associated components for Building 51, covering approximately 56,000 square feet. The scope includes installing a 70-mil thermoplastic polyolefin (TPO) roofing system, replacing four skylights, and updating the penthouse roof-access ladder to meet OSHA and VA safety standards. The estimated value of the resulting contract is between 2 million and 5 million dollars, with a required performance period of 222 calendar days from the Notice to Proceed. The project requires the contractor to manage work within an occupied 24/7 facility, necessitating a detailed phasing plan and strict adherence to infection control and HVAC-intake protection. Key technical requirements include providing a 20-year no-dollar-limit warranty, ensuring positive drainage to prevent standing water for more than 48 hours, and submitting as-built record drawings in searchable PDF and editable CAD formats. Interested firms must be registered in SAM.gov under NAICS code 236220 and provide a capability statement by November 9, 2026, including evidence of CVE certification, bonding capability, and a history of comparable work performed within the last five years.
Commercial and Institutional Building Construction

POSTED

3 days ago

DEADLINE

in 8 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS