66--Lumenera Infinity 3 Camera For the Gainesville Malcomn Randall VA Medical Center

Awarded
VA24017Q0063Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Contract Value

$8,775

NAICS

333314 - Optical Instrument and Lens Manufacturing

Place of Performance

Malcomn Randall VA Medical Center;1601 SW Archer Road;Gainesville Florida 32608 USA, PA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Sources Sought

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → Rpo East (36C24E)
ContactsNo contacts available
OfficePITTSBURGH, PA, 15212, USA
Office AddressPITTSBURGH, PA, 15212, USA
ContactsNo contact information available

Full Description

Show more
The Department of Veterans Affair, Malcom Randall VA Medical Center, located at 1601 SW Archer Road, Gainesville FL 32608, office of Research & Development, has a requirement to purchase a Lumenera Infinity 3-3UR 2.8 MP Uncooled CCD color Microscope Camera (Brand Name or Equal) as described below. This is a sources sought synopsis only. The purpose of this synopsis is to gain knowledge of potential qualified sources and their size classification (large business, small business, 8(a), SDVOSB, etc.), relative to NAICS code 333314 (size standard of 500 employees). Responses to this synopsis will be used by the Government to make appropriate acquisition decisions. Based on responses to this synopsis, the Government may issue an RFQ as a Brand Name or Equal requirement. This notice is not a request for competitive proposals, however; any responsible source who believes it is capable of meeting the requirement may submit a capability statement to the contracting office no later than Tuesday, January 17, 12:00 Noon, EST. Interest/capability statements may be sent to Linda Buccigrossi at contact@example.gov and should include company name, address, point of contact, business size, and product information. No telephone responses will be accepted. This notice is to assist the Government in determining sources only. A solicitation is not currently available. If a solicitation is issued, all interested parties must respond to that solicitation announcement separately from the responses to this announcement. Delivery/Contract Period: 1/30/2017 4/30/2017 Type of Contract: Firm Fixed Price BRAND NAME OR EQUAL: Lumenera Infinity 3-3UR 2.8 MP Uncooled CCD color Microscope Camera Mfr Part No.: AU-280C-CCD Contractor Part No.: AU-280C-CCD Manufacturer: LUMENERA Product Description: Lumenera Infinity 3-3UR 2.8 MP Uncooled CCD color Microscope Camera. Image sensor: Color ICX674 CCD sensor with 2/3 optical format providing a resolution of 19 36 x 1456 using 4.54 x 4.54 ?m pixels. Frame Rate: 53 fps at 1936 x 1456, 66 fps at 1920 x 1088, 109 fps at 640 x 480. Binning Modes: 2 x 2, 4 x 4, 8 x 8 (3 x 3 mono only). Read Noise: 6.2 e- (4 taps, 16 fps, 25 C ambient, 41 C internal). Dark Current Noise: <1 e-/s (at 22 C ambient, 41 C internal). Power Requirement: External 5 V DC, 1.2 A, power supply (included), Power Consumption: 6 W maximum in full frame rate mode. Operating temperature: 0 C to +50 C. Operating humidity: 5%-95%, Non-condensing. Data Interface: USB 3.0. Lens Mount: Adjustable C-mount standard. Software compatible with Windows 10, 8, 7, XP, Vista, Mac OS X 10.7, 32 and 64-bit operating systems. Includes DVD with INFINITY ANALYZE and CAPTURE software, TWAIN driver and documentation. INFINITY3-3UR AU-280C-CCD PC & MAC Compatible. Salient Features (Features /items/contract must have) Vendor to include: Infinity 3MP HR Color Camera and software with installation and on-site training. It is vital to ensure all specifications are met for this Infinity 3MP HR Color Camera purchase, since it will be used for on ongoing research study. In addition to providing the camera and the software, the selected vendor will be responsible for providing on-site installation and hands-on training with VA Research Staff. The software will be used in conjunction with an existing microscope. CCD High-Speed, High Sensitivity Research-Grade Camera, 2.8 Megapixel Sony ICX674 CCD sensor 53 fps at full 2.8 megapixel resolution High-speed USB 3.0 interface Must be compatible with existing Zeiss Axioskop Microscope Luminera Software Installation with existing Zeiss Axioskop 2 Microscope On-site Training on camera use On-site Training on Luminera Software On-site Training on how the software and camera interface with microscope Will also provide phone and web support with dedicated staff subsequent to on-site training 5 year warranty

More opportunities from Department Of Veterans Affairs → Rpo East (36C24E)

Same awarding agency

NAICS: 541714
Federal
AJ12--Development/Production - Kidney GEC-Specific AAV Vector
Solicitation # 36C24E27Q0009
The Department of Veterans Affairs is issuing a Sources Sought notice to identify capable vendors for the development and production of a kidney glomerular endothelial cell specific adeno-associated virus AAV vector. This project, funded by a VA ORD Merit award, aims to create a homing peptide enabled vector platform to target the glomerular endothelium to treat kidney injury and disease while reducing off target transduction. The scope of work is divided into three primary tasks: the engineering and incorporation of targeting peptides into the AAV capsid, testing vector binding and internalization in kidney tissue slices, and evaluating the specificity and efficiency of the modified vector through bioluminescence imaging and in vivo biodistribution studies. Qualified contractors must possess extensive onsite resources, including BSL 2 laboratories, specialized DNA and RNA facilities, and advanced instrumentation such as the Agilent Fragment Analyzer and various qPCR platforms. Vendors must demonstrate proven success in animal and human cell vector delivery and maintain full compliance with AAALAC and FELASA health standards. The government requires quarterly reporting, weekly videoconferences, and biannual face to face meetings. All generated data will be subject to Government Purpose Rights, and contractors must adhere to strict federal records management and information security protocols. Interested parties must submit a capability statement, relevant literature, and socio economic status details under NAICS 541714 by November 4, 2026.
Research and Development in Biotechnology (except Nanobiotechnology)

POSTED

9 days ago

DEADLINE

in 5 days
View Details
NAICS: 339113
Federal
6636--Research Equip (LAMb) - Automatic Bedding Dispensers - LA | EDA: 9/25/26
Solicitation # 36C24E26Q0071
The Department of Veterans Affairs is seeking market information for an automated Animal Bedding Dispenser to support laboratory animal care operations at the VA Greater Los Angeles Healthcare System in North Hills, California. The equipment must deliver bedding to mouse and rat cages with a throughput capacity of up to 750 cages per hour, featuring dual dispensing modes for single and double cages, adjustable volume control, and compatibility with various cage sizes and bedding types. The system must be constructed with a 304 stainless steel interior and powder-coated steel exterior, incorporate H13 HEPA filtration with airflow between 120–160 cfm, maintain noise levels not exceeding 65 dBA, and include motion sensors and jam prevention features. Technical compliance requires certifications including CE, UKCA, and ETL, and the product must align with NAICS code 339113 and PSC 6636. Delivery is required at the specified location under a white glove service model, encompassing uncrating, installation, startup, and removal of packaging materials. The estimated delivery date is September 25, 2026, though this is not a binding contract date as the current document is a presolicitation sources sought notice for gathering industry feedback. The contracting office is the Veterans Health Administration Regional Procurement Office East in Pittsburgh, Pennsylvania, with JD Cooley as the primary point of contact. While no formal pricing, CLIN structure, or contract value is provided, the government is evaluating potential set-asides for small businesses, including HUBZone, 8(a), SDB, WOSB, SDVOSB, and VOSB concerns, and seeks capability statements limited to two pages to assess vendor qualifications. Domestic manufacturing preference is expressed, and submissions must be delivered electronically to the provided email address, with future formal solicitations expected to be posted via SAM.gov.
Surgical Appliance and Supplies Manufacturing

POSTED

3 months ago

DEADLINE

N/A
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS