6635--623-26-2-2251-0039 PERACETIC ACID MONITORING SYSTEM MUS TUL SEPG 494787 EER 262988 (VA-26-00057339)

Closed
36C25926Q0876Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The Department of Veterans Affairs, Network Contracting Office 19, is soliciting the purchase and installation of two Peracetic Acid Monitoring Systems for the Eastern Oklahoma Veterans Health Care System. The systems will be installed in the Endoscopy Department Scope Processing Rooms at the Jack C. Montgomery VAMC in Muskogee, Oklahoma, and the Ernest Childers Outpatient Clinic in Tulsa, Oklahoma. Each system must provide real-time monitoring of hazardous Peracetic Acid vapors with audible and visual alarms, a wall-mounted touch screen fixed display monitor, and a standalone computer for data tracking that is not connected to the network or internet. The contractor is responsible for providing all necessary supplies, personnel, and services, including the initial assessment of optimal sensor placement, full installation, and user training on system operation and alarm response. The contract includes a comprehensive maintenance and calibration program consisting of a base year and four option years. All delivery and installation activities must occur between 0800 and 1500, excluding US Government holidays. The Government will maintain control over facility access and perform all final inspections and acceptance of the work.

General Info

VA seeks purchase, installation, and maintenance of two Peracetic Acid Monitoring Systems.

NAICS

334519 - Other Measuring and Controlling Device Manufacturing

Place of Performance

VAMC Muskogee Oklahoma, CO, USA

Set-Aside

NONE

Documents

1
DOCX, High priority: read this first4 pages · rfq
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Presolicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → Network Contract Office 19 (36C259)
Contacts1 person available
OfficeGreenwood Village, CO, 80111, USA
Office AddressGreenwood Village, CO, 80111, USA
Contacts
Chris DeLauroPeracetic Acid Monitoring System

Full Description

Show more
Background The Eastern Oklahoma Veterans Health Care System has a requirement to purchase two Peracetic Acid Monitoring Systems, one at the Jack C. Montgomery VAMC in Muskogee, OK and one at the Ernest Childers Outpatient Clinic in Tulsa, OK. This system will be used in the Endoscopy Clinic areas where Peracetic Acid needs to be monitored for safety.
Description Purchase and Installation of two Peracetic Acid Monitoring Systems with the following characteristics:
Real time monitoring by continuously measuring for hazardous levels of Peracetic Acid Vapors in the air Audible and visual alarm when hazardous levels of Peracetic Acid Vapors are detected in the air Fixed Display Monitor Touch screen Displays real time measurements Wall mounted on a steel swivel wall mount Installation Assess each area in Muskogee and Tulsa Determine optimal locations for monitoring systems that consist of monitors and sensors Ensure proper placement of monitoring systems Ensure full functionality of monitoring systems after installation Training Train users at both sites in Muskogee and Tulsa Training should include Proper use Meaning of Alarms and how to respond Maintenance of system and how to utilize maintenance program Computer and Monitor for Data Tracking Must be standalone unit Cannot connect to the Network or Internet Direct connection to Fixed Display Monitor via cable Maintenance Program Provide all maintenance and calibration of Peracetic Acid Sensors Base Year Option Year 1 Option Year 2 Option Year 3 Option Year 4
Delivery Warehouse: Jack C. Montgomery VAMC 1011 Honor Heights Drive Muskogee, OK 74401
Scope The contractor will have the entire system delivered to the Jack C. Montgomery VAMC. The contractor will provide installation in the Endoscopy Departments Scope Processing Rooms at the Jack C. Montgomery VAMC in Muskogee, OK and the Ernest Childers Outpatient Clinic in Tulsa, OK.
Contractor delivery and installation of equipment shall take place between the hours of 0800 -1500. Vendor shall not be required, nor is authorized to perform any work on the following US Government holidays:
New Year's Day, Martin Luther King Jr's Birthday, Washington's Birthday, Memorial Day, Juneteenth National Independence Day, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, Christmas Day
POC Muskogee: Robert Neuzil - SPS Supervisor, contact@example.gov Tulsa: Tina Martin - Sterile Processing Technician, contact@example.gov Christy Iven-Jorgensen - Acquisition Utilization Specialist, contact@example.gov Contracting: contact@example.gov
CONTRACTOR FURNISHED ITEMS AND RESPONSIBILITIES The Contractor shall furnish all supplies, equipment, facilities, personnel and services required to perform the service under this contract. The Contractor shall perform all work in accordance with this Statement of Work.
NON-PERSONAL SERVICE STATEMENT The C&A requirements do not apply, a Security Accreditation Package is not required.
Contractor employees performing services under this order will be controlled, directed and supervised at all times by management personnel of the contractor. Contractor employees will perform independent of and without the supervision of any Government official. Actions of contractor employees may not be interpreted or implemented in any manner that results in any contractor employee creating or modifying Federal policy, obligating the appropriated funds of the U.S. Government, overseeing the work of Federal employees, providing direct personal services to any Federal employee or otherwise violating the prohibitions set forth in Parts 7.5 and 37.1 of the Federal Acquisition Regulation (FAR). The Government will control access to the facility and perform the inspection and acceptance of the completed work. Contract Officer Representative (COR). The COR monitors all technical aspects of the contract and assists in contract administration. The COR is authorized to perform the following functions: assure that the Contractor performs the technical requirements of the contract: perform inspections necessary in connection with contract performance: maintain written and oral communications with the Contractor concerning technical aspects of the contract: issue written interpretations of technical requirements, including Government drawings, designs, specifications: monitor Contractor's performance and notifies both the Contracting Officer and Contractor of any deficiencies; coordinate availability of government furnished property, and provide site entry of Contractor personnel. The COR is not authorized to change any of the terms and conditions of the resulting order.

More opportunities from Department Of Veterans Affairs → Network Contract Office 19 (36C259)

Same awarding agency

NAICS: 621492
New
Federal
Q531--Inpatient Dialysis Services at James Mountain Inhofe Veterans Affairs Medical Center, Tulsa, OK
Solicitation # 36C25927Q0053
The Department of Veterans Affairs, through the Network Contracting Office 19, is conducting market research via a Sources Sought notice to identify qualified providers for inpatient dialysis services at the James Mountain Inhofe Veterans Affairs Medical Center in Tulsa, Oklahoma. The anticipated requirement involves providing all necessary key personnel and dialysis-specific equipment to support Intermittent Hemodialysis (IHD) and Prolonged Intermittent Renal Replacement Therapy (PIRRT) for eligible beneficiaries. Services must be available 24 hours a day, 365 days a year, with specific response requirements stating that available personnel must be reachable by phone within 15 minutes and on-site within 4 hours. The scope specifically excludes Continuous Renal Replacement Therapy (CRRT) and Peritoneal Dialysis (PD), and all sessions must be performed under the medical direction of VA-employed nephrologists and advanced practice providers. The government is contemplating a contract structure consisting of one base year and four option years, utilizing NAICS code 621492 for Kidney Dialysis Centers with a size standard of 47.0 million dollars. Contractors must comply with VHA Handbook 1042.01, Joint Commission standards, and National Kidney Foundation guidelines, while maintaining professional liability and workers compensation insurance. Interested parties must submit a capability statement not exceeding five pages to Catherine Kennedy by November 16, 2026, at 11:00 AM MST. This submission must include company details, CAGE code, business size, and relevant contract experience. Invoices for the future contract will be managed electronically via the Tungsten website, with a submission deadline of 28 days after services are rendered.
Kidney Dialysis Centers

POSTED

2 days ago

DEADLINE

in 8 days
View Details
NAICS: 811412
New
Federal
J045--Heater Exchange Repair (Correction and Rebuild of Shell and Tube Heat Exchangers: One time Service)
Solicitation # 36C25927Q0038
Request for Quote 36C25927Q0038 is a total small business set-aside for a one-time service to correct and rebuild shell and tube heat exchangers at the Rocky Mountain Regional VA Medical Center in Aurora, Colorado. The scope of work includes cleaning and rebuilding six heat exchangers using high-pressure water cleaning or mechanical brushing, installing two new flanged hot water valves to restore system redundancy, and performing necessary leak and pressure testing. The project must be completed within 90 days of award, with a performance period starting December 1, 2026. To ensure quality and sustainability, the contractor must be the Original Equipment Manufacturer, an authorized service provider, or an authorized distributor of OEM parts, as remanufactured or gray market items are strictly prohibited. Under Amendment 0001, the government has scheduled a site visit for November 9, 2026, and extended the quotation deadline to November 12, 2026, at 12:00 PM Mountain Time. Interested vendors must submit their quotes via email to the Contract Specialist in three separate volumes covering technical capability, price, and past performance. Award will be based on a comparative analysis of price and other factors to determine the most advantageous offer. All work must comply with the Service Contract Act wage determinations for Colorado and site-specific environmental and safety requirements regarding waste disposal.
Appliance Repair and Maintenance

POSTED

2 days ago

DEADLINE

in 4 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS