Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Government of Canada was posted on June 4, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Amendment #1, 26-58018 Laboratory Wind Wall System

Closed
26-58018 Amendment 1 ModificationInternational

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 333413
New
DIBBS
FAN, VANEAXIAL
Solicitation # SPE7M0-27-Q-0111
Solicitation SPE7M0-27-Q-0111 is a Firm Fixed Price request for quotation issued by the DLA Weapons Support Maritime Supply Chain for the acquisition of one vane axial fan, NSN 4140-01-675-6709. This is designated as an emergency buy to support the USS Theodore Roosevelt (CVN-71), and as such, the government may award the contract prior to the closing date of November 4, 2026. Evaluation for award will be based on best value, with specific emphasis placed on both price and the fastest possible delivery. The required delivery date is 30 days after receipt of order, with shipments required via the fastest traceable means to the Naval Shipyard Puget Sound Detachment in San Diego, California. The contract mandates strict adherence to MIL-STD-2073-1E for packaging and MIL-STD-129 for marking, with inspection and acceptance occurring at the destination. Key regulatory requirements include compliance with the Buy American and Balance of Payments Program, safeguarding of covered defense information, and the maintenance of supply chain traceability documentation. Invoicing and receiving reports must be processed electronically through the Wide Area WorkFlow system. This procurement is not a small business set-aside and requires offerors to have current representations and certifications updated in the System for Award Management.
DLA WEAPONS SUPPORT MARITIME SUPPLY CHAIN ESOC BUYS

POSTED

about 10 hours ago

DEADLINE

in 8 days
NAICS: 333413
New
Federal
26-SIMACQ-D20-0005 D-Dept Control System Parts/Supplies BPA
Solicitation # N6339426Q4060
Solicitation N6339426Q4060 is a request for quotations to establish a multi-award, five-year Blanket Purchase Agreement (BPA) for the Naval Surface Warfare Center Port Hueneme to support D-Department control system parts and supplies. This acquisition is a total set-aside for small business concerns under NAICS 333413, with a specific focus on women-owned small businesses. The scope of work includes a diverse range of hardware, such as solid state drives, network media converters, KVM transmitters, power line filters, axial fans, and various printer consumables. All supplied items must meet the detailed technical specifications and certifications outlined in the Salient Characteristics document, including compliance with IEEE, FCC, CE, and RoHS standards. The BPA will operate on a call-order basis, with individual orders competing among BPA holders. While the maximum per-order limit is listed between 600,000 and 900,000 dollars, individual calls will not exceed the Simplified Acquisition Threshold. Awards are based on technical acceptability and responsibility, with price competition occurring exclusively at the call level. To be eligible, quoters must be authorized resellers and maintain an active CMMC Level 1 (Self) status verified in the Supplier Performance Risk System. Required submission documents include a completed price list, part list, and administrative information. Payments are processed electronically through Wide Area Workflow (WAWF), and delivery terms are F.O.B. Destination.
Commanding Officer

POSTED

about 15 hours ago

DEADLINE

in almost 5 years

AI Contract Overview

Show more

The National Research Council of Canada's Aerospace Research Centre is seeking a turnkey Laboratory Wind Wall System to support the Drone and Flight Autonomy Laboratory in Mirabel, Quebec. The system is designed for research on mid-size unmanned aircraft operating in complex aerodynamic environments, such as urban wind fields and ship airwakes. The base requirement specifies a 5m x 5m open-jet test section positioned 3m above ground level, capable of achieving maximum axial wind speeds of 21-22 m/s and adjustable turbulence intensity from 7% to 25%. Technical specifications include a ramp-up acceleration of at least 10 m/s², a ramp-down deceleration of -5 m/s² or less, and a non-dimensional swirl number of 0.5 or less at the test plane. The system must be self-supporting, compliant with the National Building Code of Canada, and operational in temperatures ranging from -20 °C to +30 °C with IP 34 protection standards. The contract includes an option for the NRC to expand the system to 7m x 7m, and bidders must provide separate pricing for this configuration. Evaluation is based on a weighted score consisting of technical merit (60%), Canadian value-added (25%), and price (15%), with mandatory technical criteria serving as pass/fail gates. The successful contractor is responsible for the design, fabrication, delivery, and commissioning of the system, including the supply and installation of the grade-level foundation. All deliverables must be provided in both English and French, with a final delivery deadline of March 31, 2028. The contract also mandates a minimum one-year warranty and requires that all electrical equipment be CSA certified and compliant with the Canadian Electrical Code.

General Info

Design, delivery, and commissioning of a customizable Laboratory Wind Wall for aerospace research.

Documents

25

26-58018 Amendment 007 - Laboratory Wind Wall System RFP

PDF, High priority: read this first2 pages · amendment
High

26-58018 Amendment 007 - Système de mur de vent pour laboratoire

PDF, High priority: read this first2 pages · amendment
High

Amendment 001 to RFP 26-58018 Laboratory Wind Wall System

PDF, High priority: read this first2 pages · amendment
High

Amendment 003 to RFP 26-58018 Laboratory Wind Wall System

PDF, High priority: read this first2 pages · amendment
High

Modification 001 to RFP 26-58018 Système De Mur De Vent Pour Laboratoire

PDF, High priority: read this first2 pages · amendment
High

Q&A for RFP 26-58018 Laboratory Wind Wall System

PDF, High priority: read this first2 pages · q-and-a
High

Q&A for RFP 26-58018 Wind Wall System

PDF, High priority: read this first1 page · q-and-a
High

Q&A for RFP 26-58018 Wind Wall System

PDF, High priority: read this first1 page · q-and-a
High

Q&A for Solicitation 26-58018 Wind Wall System

PDF, High priority: read this first2 pages · q-and-a
High

RFP 26-58018 Laboratory Wind Wall System

PDF, High priority: read this first71 pages · rfp
High

RFP 26-58018 Laboratory Wind Wall System

PDF, High priority: read this first71 pages · rfp
High

RFP 26-58018 Laboratory Wind Wall System Amendment 002

PDF, High priority: read this first2 pages · amendment
High

RFP 26-58018 Laboratory Wind Wall System Amendment 004

PDF, High priority: read this first2 pages · amendment
High

RFP 26-58018 Laboratory Wind Wall System Amendment 005

PDF, High priority: read this first2 pages · amendment
High

RFP 26-58018 Système De Mur De Vent Pour Laboratoire

PDF, High priority: read this first76 pages · rfp
High

RFP 26-58018 Système De Mur De Vent Pour Laboratoire

PDF, High priority: read this first76 pages · rfp
High

Solicitation 26-58018 Amendment 002 for Système De Mur De Vent Pour Laboratoire

PDF, High priority: read this first2 pages · amendment
High

Solicitation 26-58018 Amendment 003 for Système De Mur De Vent Pour Laboratoire

PDF, High priority: read this first2 pages · amendment
High

Solicitation 26-58018 Amendment 004 for Wind Wall System

PDF, High priority: read this first2 pages · amendment
High

Solicitation 26-58018 Amendment 005 for Système De Mur De Vent Pour Laboratoire

PDF, High priority: read this first2 pages · amendment
High

Solicitation 26-58018 Amendment 006

PDF, High priority: read this first2 pages · amendment
High

Solicitation 26-58018 Amendment 006 for Système De Mur De Vent Pour Laboratoire

PDF, High priority: read this first2 pages · amendment
High

Solicitation 26-58018 Wind Wall System Q&A June 9, 2026

PDF, High priority: read this first3 pages · q-and-a
High

RFP 26-58018 Q&A No. 5 – Laboratory Wind Wall System

PDF, Medium priority1 page · q-and-a
Medium

26-58018 Q&A 6 - Laboratory Wind Wall System

PDF, Low priority1 page · q-and-a
Low

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGovernment of Canada → National Research Council of Canada
Contacts1 person available
OfficeN/A
Office AddressN/A
Contacts
Katie HomuthContracting Authority

Full Description

Show more
Amendment #1 RFP 26-58018 Laboratory Wind Wall for Unmanned Aircraft Complex Flow Testing This amendment is issued to modify the solicitation following Question and Answer #1 posted on Canada Buys 06 June 2026. See the modification to the solicitation below. MODIFICATIONS TO THE SOLICITATION ____________________________________________________________________________________________________ At Annex Statement of Requirement, sub-section 1.1 Technical Requirement/Specifications, 1.1.2 Wind Wall Airflow Performance: DELETE: section e. in its entirety; and REPLACE with: e. The System must achieve ramp‑up acceleration ≥ 10 m/s² and ramp‑down deceleration ≤ −5 m/s². The swirl number at the TP must be ≤ 0.5 (non‑dimensional). ALL OTHER TERMS AND CONDITIONS REMAIN THE SAME __________________________________________________________________________________________________________________________________________________________________________ RFP 26-58018 Laboratory Wind Wall for Unmanned Aircraft Complex Flow Testing The National Research Council of Canada’s - Aerospace Research Centre (NRC AERO) has a requirement for the design, fabrication, delivery, and commissioning of a Laboratory Wind Wall System (The System). The System will support NRC’s Drone and Flight Autonomy Laboratory (DFAL) in research focused on the performance, control, and safety of mid‑size unmanned aircraft (drones) operating in complex aerodynamic environments, such as ship airwakes and urban wind fields, across all Canadian seasons. The System must provide controlled, repeatable, and configurable airflow conditions for testing unmanned aircraft in free flight. BACKGROUND: The aerodynamic performance and stability of unmanned aircraft operating in complex wind environments are not yet fully understood, particularly across different propulsion configurations. NRC’s research program requires a large‑scale Wind Wall System capable of generating controlled wind and turbulence conditions for outdoor free‑flight testing of mid‑size unmanned aircraft. The System will form part of a new outdoor test capability at NRC’s Drone and Flight Autonomy Laboratory (DFAL) located at the NRC Mirabel site. This facility will enable the evaluation of aircraft systems and Small and Medium Enterprise (SME) developed technologies under controlled aerodynamic conditions representative of operational environments in Canada, including ship airwakes and urban wind fields. DEFINITIONS: Wind Wall A vertically stacked array of fans that generate a horizontal wind flow-field exiting from one vertical face. The overall Wind Wall dimensions in this document refer to the exit face width and exit face height of the fan array. The Wind Wall depth includes only the fans and supporting structure (no airflow contractions or surrounding building) to minimize the System footprint. Marketable Wind Wall System A finished, polished version that meets quality standards, is compliant with regulations, and is ready for sale at scale or customized. Turbulence Intensity Turbulence intensity refers to local turbulence intensity for which the reference wind speed is measured locally. 1.0 REQUIREMENT: The Offeror must design, manufacture, deliver, and commission a turnkey Laboratory Wind Wall System that meets or exceeds the technical and operational requirements defined in this Statement of Requirement (SOR). The System must be capable of generating controlled, repeatable, and complex airflow conditions suitable for unmanned aircraft free flight testing. 1.1 Technical Requirements/Specifications 1.1.1 Wind Wall System i. The System must include an open‑jet test section to allow for free‑flight testing of aircraft. ii. The Wind Wall jet face must have nominal dimensions of 5 m × 5 m (± 0.25 m tolerance). iii. The bottom of the jet face must be positioned 3 m above ground level, and the center of the test region must be 5.5 m above ground. iv. The Test Plane (TP) must be located 5 – 6 m downstream of the Wind Wall, with a minimum of 4 m x 4 m of uniform jet flow. v. The design must allow for an optional expansion of the Wind Wall to 7 m × 7 m (± 0.25 m in width and height), as described in Section 1.1.6 Optional Expansion Scope. - The bottom of the Wind Wall must remain 3 m above ground level. - The increase in width must be symmetric about the lateral centre of the Wind Wall exit face, and the height extension must occur upward from the top edge of the existing structure. - The additional fan modules required for the optional configuration must be equivalent in size, capacity, and performance to those used in the 5 m × 5 m base Wind Wall system. - The optional expansion must be structurally and functionally compatible with the base Wind Wall foundation, controls, and safety systems. 1.1.2 Wind Wall Airflow Performance a. The maximum axial wind speed at the TP must be 21–22 m/s, with maximum axial turbulence intensity of ≤ 7%. b. The System must provide adjustable turbulence intensity at the TP ranging from 7% to 25% in the streamwise component, while maintaining a maximum wind speed of ≥ 15 m/s. c. The minimum axial wind speed at the TP must be 1 m/s. d. The fan array design must support gradients of 2 m/s per metre (horizontal or vertical) and integral length scales of 2–50 m. e. The System must achieve ramp‑up acceleration ≥ 10 m/s² and ramp‑down deceleration ≤ −5 m. The swirl number at the TP must be ≤ 0.5 m/s². f. Each fan must support independent and synchronized control, with incremental speed changes ≤ 0.2 m/s. 1.1.3 Equipment and System Requirements The System must: • operate without performance derating from 0 °C to +30 °C; • have minimal performance derating from −20 °C to +30 °C; • be suitable for cold starts (−20 °C to +20 °C) for ≥ 800 cycles; • be storable from −20 °C to +60 °C; • be designed, constructed, and tested so it can operate normally and safely in light rain or snow conditions, without loss of performance, safety, or durability, and must meet at least IP 34 protection standards; • have a minimum operational lifespan of 20,000 hours; • be delivered as a turnkey solution, fully operational upon commissioning and compliant with all specified requirements. The System’s high‑voltage components (> 750 V) must be enclosed in an IP 65‑rated cabinet. The Wind Wall electrical system must be compatible with standard North American industrial electrical systems operating at 60 Hz. The Offeror must specify the required electrical service for the system, including voltage, phase configuration, total connected load (kW), apparent power (kVA), and power factor at full load. Where the proposed system requires a voltage different from typical Canadian building distribution systems (for example, 600/347 VAC or 208/120 VAC), the Offeror must provide the necessary transformers, converters, or other power conditioning equipment as part of the Wind Wall System. The Offeror must provide the estimated peak electrical demand and total connected load for the Wind Wall System as part of the proposal so that NRC can assess compatibility with the available site electrical infrastructure. All electrical equipment supplied as part of the Wind Wall System must be certified by the Canadian Standards Association (CSA) or by another certification body accredited for use in Canada and acceptable to the authority having jurisdiction. The electrical installation and equipment must comply with the Canadian Electrical Code (CSA C22.1) and all applicable provincial regulations. 1.1.4 Structural Support and Grade-Level Surface Interface Requirements a. The grade level foundation and support framing must be supplied and installed by the Offeror. The design must be structurally engineered to safely withstand all static loads (including system weight and terrestrial wind conditions) and dynamic loads generated during wind-on testing under all anticipated operational conditions. b. The Wind Wall support framing must be mechanically anchored to the grade level foundation (pad) using fastening and reinforcement methods appropriate for the loading conditions described in paragraph (a). c. The Offeror must ensure that all foundation, structural, and anchoring details comply with applicable Canadian building codes, engineering standards, and site-specific geotechnical recommendations. d. All design calculations, load assessments, and anchoring specifications must be sealed by a licensed professional engineer and included in the Offeror’s submission for NRC review and approval prior to fabrication and installation. e. The structure of the Wind Wall system must: • be self supporting and capable of being anchored to an engineered foundation; and • comply with the wind load requirements of the National Building Code of Canada (NBCC) and any other applicable codes and standards. 1.1.5 Operational Requirements • Control Software Compatibility: The control software must be compatible with common operating systems such as, but not limited to, Microsoft Windows 10 or 11 (Professional or Enterprise editions) and current Linux distributions (for example, Ubuntu LTS, Red Hat Enterprise Linux, or Debian). Other platforms may be considered if full functionality, interoperability, and technical support are demonstrated. • Information Security and Data Protection: The System must adhere to recognized information security and data protection practices to safeguard operational and research data. All communications and data transfers must use secure, encrypted protocols (such as HTTPS, SFTP, or TLS 1.2 or higher) to ensure confidentiality and integrity. • Data Output and Synchronization: Wind profile output data must be GPS timestamped. The software must support an external trigger for synchronized data logging and must allow automation, storage, and repetition of Test Plane (TP) wind profiles for consistent experimental conditions. • System Reliability and Redundancy: The system must allow continued operation in the event of an individual fan failure without compromising overall airflow control or test stability. • Safety Controls: An emergency stop system must be installed at the operator location, providing immediate system shutdown capability in accordance with applicable electrical and mechanical safety standards. 1.1.6 Optional Expansion Scope The National Research Council of Canada (NRC) reserves the right to exercise an option to obtain a larger Wind Wall system at the time of contract award or during the contract period by way of a contract amendment. a. Scope of the Option • The design of the base Wind Wall must allow for an optional expansion to 7 m × 7 m (± 0.25 m in width and height). • The bottom of the Wind Wall must remain 3 m above ground level in both the base and expanded configurations. • The increase in width must be symmetric about the lateral center of the Wind Wall exit face, and the height extension must occur upward from the top edge of the existing structure. • The additional fan modules required for the optional configuration must be equivalent in size, capacity, and performance to those used in the 5 m × 5 m base Wind Wall system. • The optional expansion must be structurally and functionally compatible with the base Wind Wall foundation, support framing, controls, power distribution, and safety systems. • The expanded system must maintain equivalent design, safety, and performance standards as the base Wind Wall system, with proportional scaling of structural and control components. • The optional configuration must be capable of achieving wind speeds exceeding 21 m/s and supporting applications consistent with small aviation testing and/or wind simulation in research environments. b. Bidder Requirements Bidders must include technical specifications and design drawings for the optional configuration and pricing details for the 7 m × 7 m Wind Wall in Annex Basis of Payment, Optional Table 1. Pricing for the optional system must be identified separately from the base system pricing in the financial proposal. Bidders must indicate any lead time, production schedule, or delivery considerations associated with the larger configuration. The optional design must remain interoperable with the base system’s control software, data interfaces, and safety features. c. Contractual Option The NRC may, at its sole discretion, exercise this option in whole or in part at the time of contract award or at a later date during the contract period. Exercising the option will be subject to the same terms and conditions as the base contract, except where otherwise specified and agreed upon in writing. The Offeror must honour the proposed pricing and delivery commitments for the optional configuration for a period of up to 14 months following contract award. 2.0 WARRANTY AND SUPPORT: • Minimum one (1) year warranty covering all parts and labour. • Offeror must provide technical support (phone and email) for the duration of the warranty. 3.0 MAINTENANCE AND HARDWARE SUPPORT: The Offeror must provide hardware support throughout the warranty period, including: • Replacement of defective components; • Troubleshooting and repair assistance; • Access to a technical support team by phone or email; • A detailed maintenance and service manual must be provided with the System. 4.0 TECHNICAL DOCUMENTATION: The Offeror must supply a comprehensive technical manual, including system diagrams, maintenance and troubleshooting procedures, and instructions for live and recorded data collection. 4.1 References • National Building Code of Canada, latest edition; • Applicable Canadian Standards Association (CSA) standards for electrical equipment and industrial control panels; • Canadian Electrical Code (CSA C22.1), latest edition; • International Electrotechnical Commission (IEC) and European Norm (EN) (IEC/EN) standards applicable to electrical safety and Ingress Protection (IP) ratings. 5.0 DELIVERY ADDRESS: National Research Council Canada YMX Innovation Centre 9800 Rue Irénée-Vachon Mirabel, Québec J7N 3C5 Canada 6.0 LANGUAGE OF WORK: • All deliverables, including reports, documentation, and training materials, must be provided in both English and French, in accordance with the Official Languages Act. • Meetings and communications will be conducted primarily in English, with French language support provided for stakeholders as required. 7.0 LOCATION OF WORK: • Manufacturing of sub-assemblies: at the Offeror’s facilities. • Final assembly and integration: at NRC’s Mirabel laboratory site adjacent to the wind wall foundation. • For construction site access, if NRC visitor requirements apply during the assembly period, Persons Granted Access (PGA) requirements must be arranged prior to on-site work activities. 8.0 TRAVEL AND DELIVERY: • All travel and delivery costs are to be included in the Offeror’s pricing. • No travel reimbursement will be provided. • Any additional travel must be pre approved in writing by the Project Authority and comply with the Government of Canada Travel Directive.

More opportunities from Government of Canada → National Research Council of Canada

Same awarding agency

NAICS: 541330
New
International
M55 Commissioning and Integrated Systems Testing
Solicitation # 26-58146
The National Research Council Canada is soliciting offers for commissioning and integrated systems testing services for new and existing equipment and systems at building M55 in Ottawa, Ontario, as part of the Office Accommodations Project. This solicitation, number 26-58146, supersedes a previous request and requires all work to be completed within 95 weeks of the notification of acceptance. The scope includes providing a third-party independent commissioning agent to manage the process, developing a master commissioning plan, conducting functional verification, and providing comprehensive operation and maintenance training for staff. All deliverables must adhere to the NRC Construction Documentation and Deliverables Manual and specific commissioning standards, including CSA Z320-11, NFPA, and AWWA. Award selection is based on the lowest responsive bid that meets mandatory technical criteria, which include demonstrated experience as a Commissioning Service Provider on two building construction projects and experience as an Integrated Testing Coordinator on at least one project with a minimum construction value of 5 million dollars. Proposals must be submitted in separate technical and financial components by November 5, 2026, with the technical section limited to nine pages. The contract includes strict security clearance requirements, confidentiality obligations, and a structured payment process where progress payments are issued within 30 calendar days of receiving an acceptable invoice. Final acceptance is contingent upon the approval of all commissioning documentation, successful system verification, and the completion of required personnel training.
Engineering Services

POSTED

6 days ago

DEADLINE

in 9 days
View Details
NAICS: 238160
New
International
Roof Replacement Building M-20
Solicitation # 26-58140
Solicitation 26-58140 is an invitation to tender issued by the National Research Council Canada for the replacement of various roof areas at Building M-20, located at 1200 Montreal Road in Ottawa, Ontario. The project requires the supply and installation of roofing systems as detailed in the technical plans, with a strict performance period of seven weeks following acceptance. Bidders were required to attend one of two mandatory site visits on October 6 or 7, 2026. While the original closing date was October 20, 2026, Amendment 1 extended the submission deadline to October 27, 2026, at 2:00 p.m. EDT. The contract mandates rigorous compliance with health and safety standards, including the Canada Labour Code and Ontario Occupational Health and Safety regulations, and requires a specific insurance policy for torch-applied systems. Key deliverables include a project construction progress schedule, a site-specific health and safety plan, and a waste management plan demonstrating that 90 percent of construction waste is recycled or salvaged. Award requirements include the submission of performance and labour and material payment bonds, as well as a listing of all subcontractors and suppliers to avoid disqualification. Payments are governed by the Federal Prompt Payment for Construction Work Act, ensuring payment within 28 calendar days of a proper invoice.
Roofing Contractors

POSTED

6 days ago

DEADLINE

in 7 days
View Details
NAICS: 541350
New
International
Various equipment
Solicitation # 25-58191
The National Research Council Canada is soliciting a Standing Offer for the supply, delivery, installation, and commissioning of various scientific and laboratory equipment to support research activities across multiple sites in Canada. A critical component of this procurement involves third-party inspection services, including initial and follow-up plant inspections conducted in Canada, the United States, or via virtual means. Service providers must hold a valid ISO/IEC 17020 accreditation recognized by the International Laboratory Accreditation Cooperation and adhere to strict CCMC marking and labeling requirements. The initial period of performance is set from April 1, 2026, to March 31, 2027, with the possibility of four additional one-year extensions through March 31, 2031. Award selection is based on the highest combined rating of technical merit, weighted at 65 percent, and pricing, weighted at 35 percent. To be compliant, offerors must achieve a minimum of 15 points on the technical evaluation. Pricing is evaluated on a lowest-cost basis across specific inspection codes. Proposals must be submitted as separate technical and financial attachments, with a strict prohibition against including pricing in the technical volume to avoid disqualification. Administrative requirements include compliance with reciprocal procurement policies, anti-forced labour regulations, and the provision of security clearance levels. Payments are processed through various electronic methods, including direct deposit and Mastercard purchase cards, managed by the NRC Finance and Procurement Directorate in Ottawa.
Building Inspection Services

POSTED

7 days ago

DEADLINE

in 8 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS