Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity was posted on August 4, 2016. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Audiometer

Awarded
W81K0016T0150Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334510
New
Federal
Hearing Aid Fitting and Verification for Shiprock Service Unit (IEE or ISBEE Set Aside)
Solicitation # SS-SRSU-27-0003
The Indian Health Service Shiprock Service Unit is conducting market research through a sources-sought notice to identify capable Indian-owned economic enterprises, both large and small, to provide hearing aid fitting and verification services. The primary objective is to reduce hearing aid rejection and costly remakes while ensuring patients receive optimal benefit from their devices. The requirement includes the provision of equipment with advanced technical specifications, such as dual ear capability, a frequency range of 200 to 16,000 Hz, and a comprehensive test suite including speechmap counseling and pediatric probe tube placement. Additionally, the selected vendor must provide installation and training for the Audiology Department. This opportunity is categorized under NAICS code 334510 for electronic hearing aid manufacturing. In accordance with the Buy Indian Act, the government will prioritize responses from Indian-owned economic enterprises before considering other small business set-aside programs. Interested parties must be registered in the System for Award Management and submit a company profile, a capability statement, and a completed IHS IEE Representation Form by November 03, 2026. This notice is for market research purposes only and does not constitute a formal solicitation.
Navajo Area Indian Health Svc

POSTED

2 days ago

DEADLINE

in 4 days
NAICS: 334510
New
Federal
Ocular Scanner
Solicitation # W91CRB-26-AWSP-Scanner-Ultrasonic-Ocular-RPP
The Portfolio Acquisition Executive Maneuver Ground Project Manager Maneuver Medical Systems is soliciting prototype proposals for a Scanner Ultrasonic Ocular device under Other Transaction Authority pursuant to 10 U.S.C. 4022. The objective is to award two prototype agreements for the delivery and demonstration of FDA-approved commercial solutions that provide anatomical visualization and diagnostic imaging of the eye, specifically for the anterior and posterior segments. Awardees are required to deliver four prototype units within 45 to 60 days of award for operational and environmental testing conducted in accordance with MIL-STD-810H. The estimated period of performance is twelve months, with awards expected around the first quarter of fiscal year 2027. The procurement utilizes a comparative best-value methodology, prioritizing technical approach, performance compliance, reliability, schedule realism, and past performance over cost. Key requirements include Trade Agreements Act compliance, MIL-STD-130N marking for hardware, and the provision of ruggedized transport cases. Deliverables encompass the hardware units, comprehensive user and maintenance manuals, cybersecurity documentation, and on-site operator training. Proposals must be submitted as four separate PDF volumes via DoD SAFE or secure email by November 12, 2026. This action is a direct Other Transaction Agreement and is not subject to the Federal Acquisition Regulation or Defense Federal Acquisition Regulation Supplement.
W6QK Acc-Apg

POSTED

3 days ago

DEADLINE

in 13 days

AI Contract Overview

Show more

This contract is for the procurement of a Clinical Audiometric Suite to be utilized at Fort Carson, Colorado. A critical requirement is that all provided equipment must be fully compatible with AudBase software, as mandated by the Department of Defense and the hearing center of excellence for documenting diagnostic exams. The suite must include a two-channel clinical diagnostic manual audiometer, a tympanometer, soundfield speakers, and a room monitor for patient counseling. If the system is computer-based, it must feature a dedicated audiometer control panel and necessary accessories for dual-function operation. The audiometer must support a wide frequency range from 125Hz to 20,000Hz and include capabilities for air, bone, and sound field conduction, as well as specialized DOD tests like the Speech Recognition in Noise Test. The accompanying tympanometer must be capable of performing various middle ear analyses, including acoustic reflex thresholds and Eustachian tube function tests, featuring an internal color touchscreen and printer. The equipment is designed for high-precision diagnostic and screening protocols, ensuring comprehensive auditory assessment capabilities.

General Info

Agency

N/A

Contract Value

$35,697.5

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing

Place of Performance

Evans Army Community Hospital 1650 Cochrane Circle, Fort Carson, CO, 80913, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Combined Synopsis

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts1 person available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts

Full Description

Show more
Salient Characteristics: Clinical Audiometric Suite All equipment must be compatible with AudBase software approved by DOD and required by the hearing center of excellence for use in documenting clinic diagnostic exams. In the room monitor to provide counseling to patient required. Audiometer, Tympanometer, Soundfield speakers and additional accessories to run equipment required. If computer based, must have audiometer control panel as well as computer accessories for dual function. Audiometer Audiometer must be a two-channel clinical diagnostic manual audiometer. - Pure Tone - Two Independent Channels - Frequency Range: Full Frequency Range: 125Hz to 20,000Hz Air Conduction: 125Hz to 12,000Hz High Frequency: 8,000Hz to 20,000Hz Bone Conduction: 250Hz to 8,000Hz Sound Field and Paired Inserts: 125Hz to 8,000Hz - Intensity Range: Air Conduction (TDH): -10dB HL to 120dB HL Bone Conduction: Mastoid: -10dB HL to 75dB HL, Forehead: -10dB HL to 70dB HL Sound Field: -10dB HL to 90dB HL Masking: Narrow Band Noise, White Noise, Speech Noise - Format: Steady, Pulsed or FM tone - Communications and Monitoring: Talk Forward, Talk Back, Monitor, Aux Intercom - Special Tests (user defined): MLB, Lombard Test, Pure Tone Stenger, Speech Stenger and SAL. Ability to add speech tests to the existing list of pre-programmed tests such as the Speech Recognition in Noise Test (SPRINT) that is unique to the DOD. - Special Tests: ALT (ABLB), SISI, High Frequency, TEN, QuickSIN, Tympanometer (Middle Ear Analyzer) - General Specifications o Size: 16"(W) x 11"(D) x 14.5"(H), Weight: 12 lb. o Test Types: Tympanometry, Acoustic Reflex Threshold, Reflex Decay, Eustachian Tube Function (Intact and Perforated) o Protocols: Diagnostic, Screening, Two-Component Tympanometry, User-defined o Display: Internal Color Touchscreen and optional eternal HDMI monitor o Interface: USB (keyboard, mouse, Flash Drive, PC communications) o Printout: Internal Printer o Probe Tone: - 226 Hz (85 dB SPL - 1.5 dB) 678 Hz (72 dB SPL - 1.5 dB) 1000 Hz (69 dB SPL - 1.5 dB) - Admittance Measurements Range: 226 Hz (-7.0 to +7.0 mmho) 678 Hz (-21.0 to +21 mmho)1000 Hz (-32.0 to +32 mmho) Sensitivity Scale: Auto Scales to Appropriate Range, Manual selection also possible in Reflex Modes only - Pressure Measurements (load volume of 0.2 to 7.0 ml) Range: Normal = +200 to -400 daPa Wide = +400 to -600 daPa Sweep Rate: 12.5, 50.0, 200, 600 and 600/200 daPa/sec. Sweep Accuracy: 10% of nominal rate Maximum limits (in 0.5cc cavity): -800 daPa and +600 daPa - Reflex Measurements Stimuli: 250, 500, 1k, 2k, 4k, BBN, LBN, HBN, Click, External Input, Non-acoustic

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS