Automated Liquid Handling Platform
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
This contract is for the one-time acquisition of an automated liquid handling platform, specifically identifying the Agilent Technologies Bravo as the only model meeting the required specifications. The equipment must be newly manufactured and capable of fitting and operating within a biosafety cabinet measuring 46 inches wide by 24 inches deep by 30 inches high, with a weight limit of 120 pounds. Key functional requirements include the ability to perform serial dilutions, support for interchangeable 96-channel and 384-channel pipetting heads, and a minimum 15-position deck capacity. The platform must dispense volumes from 0.1 to 200 microliters with a maximum deviation of 5 percent and include a dedicated computer, controller, and software for custom protocols. It must operate under ambient conditions between 5 and 40 degrees Celsius and be compatible with standard microplates. Additionally, the system must be capable of future configurations for shaking, heating, cooling, and filtration, and must comply with all applicable federal, state, and local safety standards.
General Info
Agency
NAICS
Place of Performance
Silver Spring, MD, 20993, USASet-Aside
Documents
(2)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
Response Deadline
Organization & Contact Information
Full Description
This requirement is for a one-time acquisition of twenty (20) implantable medical-grade primary lithium batteries of Lithium Silver Vanadium Oxide, Carbon Monofluoride (Li/SVO-CFx) chemistry, consisting of two configurations of ten (10) batteries each.
All equipment shall be newly manufactured. It shall not be used, refurbished, reconditioned, remanufactured, or previously used for demonstration.
Salient characteristics:
The equipment shall meet the following salient characteristics: a benchtop automated liquid handling platform, user-friendly and easy to operate and clean, of space-saving and energy-saving design, capable of fast automatic pipetting of multiple solutions and of serial dilutions across or down the plate; able to accommodate variable liquid volumes; able to pipette into single rows, single columns, or individual wells as selected by the user in a 96-well or 384-well format, with the well format interchangeable based on user requirements; customizable to the laboratory's assay needs; equipped with programmable operating temperatures permitting use across a range of temperatures; and usable within the containment enclosure identified in the minimum technical requirements below to permit handling of sterile or hazardous materials.
Based on our research, only a specific make and model meets our needs, the Agilent Technologies Bravo Automated Liquid Handling Platform. It is the only equipment in its class that can meet our minimum needs as listed in the specifications. Other machines do not dispense low volumes, are much larger than this machine and do not fit within a biosafety cabinet.
Minimum technical requirements
The equipment shall meet the following minimum requirements:
-
The platform shall be benchtop in format and shall fit and operate within a biosafety cabinet of dimensions of 46in W X 24in D X 30in H that will support 120 lbs without disrupting the enclosure airflow.
-
The platform shall perform serial dilutions either across the plate or down the plate using standard disposable tip heads.
-
The platform shall use 96-channel or 384-channel pipetting heads that are interchangeable, with independent tip pickup capability.
-
The platform shall provide a minimum 15-position deck capacity.
-
The platform shall dispense from 0.1 to 200 microliters. Dispensing accuracy and precision shall be no worse than 5% deviation.
-
The platform shall be configurable to support shaking, heating, cooling, and filtration. These configurations are not required to be delivered with the platform; however, the platform shall be capable of accepting these configurations at a later date, if desired.
-
The platform shall include a controller and software to generate custom protocols.
-
The platform shall include a dedicated computer to control the machine.
-
The platform shall be compatible with standard format microplates (96-well and 384-well).
-
The platform shall operate under ambient conditions of 5 to 40 degrees Celsius and 10 to 90 percent relative humidity, non-condensing. No deck or plate temperature-control range is required.
-
Compliance with all applicable Federal, state, and local safety standards
Similar Contracts
Same NAICS industry code
More opportunities from Department Of Health And Human Services → FDA Office Of Acq Grant Svcs
Same awarding agency
Ready to Pursue This Opportunity?
Get AI-powered intelligence on this solicitation and the ones like it