Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Veterans Affairs was posted on February 13, 2017. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

C--Upgrade Primary Loop Project 610-16-105

Awarded
VA25116R0256Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
SLED
Road Asset Management
Solicitation # FY27-ENGCP-002-6
The Bulloch County Board of Commissioners is soliciting Statements of Qualifications for project FY27-ENGCP-002-6, focused on Road Asset Management. The selected consultant will be responsible for collecting and analyzing field data, creating a road asset inventory, and developing a Capital Improvement Plan with an outlook extending to FY 35. The scope includes GIS database development, web-based mapping, and the identification of structural hazards and drainage failures to minimize safety risks and legal liability. All prime and sub-consultants must be GDOT Prequalified Contractors as of the submission deadline on November 20, 2026, at 3:00 PM EDT. Proposals are evaluated based on a composite scoring system that weights prime consultant experience and technical approach at 20% each, GIS capabilities at 20%, asset prioritization methodology at 15%, workload capacity at 15%, and past references at 10%. The highest-ranked consultant will be invited to negotiate a contract. Key requirements include a Principal-in-Charge with at least 10 years of industry experience and comprehensive insurance coverage, including professional malpractice and general liability of at least 1 million dollars per occurrence. Submissions are limited to ten pages, excluding mandatory forms and charts, and must include a Non-Collusion Affidavit and Bidder Declaration. Either party may terminate the resulting agreement with 30 days written notice.
Bulloch County Board of Commissioners

POSTED

about 8 hours ago

DEADLINE

in 22 days
NAICS: 541330
New
International
CoT RFP Event Q30-01-2026-27
Solicitation # Q30-01-2026-27
The City of Tshwane is soliciting a service provider for professional engineering services to support town planning subdivision application processes on city-owned properties. The scope of work is divided into three primary categories: Civil Services Reports, Geotechnical Investigations, and Route Determination Reports. All services must be led by a Professional Engineer registered with the Engineering Council of South Africa and must comply with the Gauteng Transport Infrastructure Act, National Building Regulations SANS 10400, and various SANS and SANRAL standards. The project follows a strict timeline, requiring an inception meeting within one month, draft reports within three months, final reports within five months, and project close-out within six months of appointment. The solicitation, numbered Q30-01-2026-27, closes on November 12, 2026, at 10:00. Awards are based on an 80/20 preferential point system in accordance with the Preferential Procurement Policy Framework Act and 2022 Regulations, with specific goals including points for women-owned, youth-owned, and disability-owned enterprises, as well as local economic participation. Evaluation occurs in four stages, starting with administrative responsiveness and a functionality score of at least 70 out of 100. Successful bidders must enter into a Service Level Agreement, with payment terms set at 30 days following the receipt of an invoice. Required submission documents include company registration, tax clearance or a CSD unique pin, and B-BBEE certification.
City of Tshwane

POSTED

about 10 hours ago

DEADLINE

in 13 days

AI Contract Overview

Show more

This procurement is restricted to Service Disabled Veteran Owned Small Business firms located within a 150 mile radius of the VA Northern Indiana Health Care System in Marion, Indiana. The selected Architect/Engineer firm will provide professional design services for the Upgrade Primary Loop project, which includes schematic design, design development, and construction documents. The scope of work is divided into three parts: addressing specific electrical deficiencies such as replacing utility transformers and distribution boards, reviewing the main electrical loop for code violations and improvements, and evaluating the existing emergency power distribution system and generators. The project has an estimated construction value between 2 million and 5 million dollars, with a total design timeframe of approximately 188 calendar days. The firm is responsible for site verification, providing AutoCAD 2016 drawings, and performing seven site visits during the construction period. Qualified firms must submit a Standard Form 330 qualification package to be evaluated based on professional qualifications, specialized experience, professional capacity, and past performance. A firm fixed price contract is intended for the award.

General Info

Contract Value

$212,611.5

NAICS

541330 - Engineering Services

Place of Performance

OH, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Combined Synopsis

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)
ContactsNo contacts available
OfficeDAYTON, OH, 45428, USA
Office AddressDAYTON, OH, 45428, USA
ContactsNo contact information available

Full Description

Show more
This Architect/Engineer procurement is restricted to Service Disable Veteran Owned Small Business (SDVOSB) firms located within a 150 mile radius of the VA Northern Indiana Health Care System, Marion Campus, 1700 E. 38th St. Marion, IN 46953. This requirement is being procured in accordance with the Selection of Architects and Engineers Statute as implemented in FAR Subpart 36.6. Applicable NAICS code is 541330 and small business size standard of $15 Million. The Architect Engineer (AE) firm shall provide architectural and design services necessary to furnish: A. The Architect/Engineer (A/E) firm shall furnish professional services for 100% design for project 610-15-105, Upgrade Primary Loop at VA Northern Indiana Health Care System, Marion Campus, 1700 E. 38th ST., Marion, IN 46953. The design will include Schematic Design, Design Development, and Construction/Bid Documents per the A/E Design Submission Instructions Document, Construction Administration Services, Technical Specifications and Cost Estimates. B. The A/E firm shall be responsible for site review of the facility in order to field verify existing conditions, documents and as-built drawings. C. The A/E firm shall provide final construction drawings in AutoCAD 2016 format. D. The A/E firm shall provide computations and sizing calculations for electrical designs. For computerized calculations, submit complete and clear documentation of computer programs, interpretation of input/output, and description of program procedures. E. The design will include three (3) parts: 1. Part - 1: Design of a construction project to address known deficiencies identified by various tests and observations by VA NIHCS noted below. a. Replacement of two (2) outdoor utility transformers that have exceeded their normal life expectancy and fail testing due to high levels of methane. b. Replace the 15KV loop switch that serves building 174. The switch displays signs of arc flashing and presents a hazard to the electrical staff when servicing. Failure could result in a prolonged power outage to the building. c. Replace two (2) 208V / 3-phase main distribution boards serving building 138. Both distribution boards are out-of-date and spare parts are no longer available. Replacement will require temporary power distribution during construction. d. Replace nine (9) outdoor utility transformers which fail CO2 testing including feeder cables from transformer to building main distribution panels. e. Correct breaker coordination based on the existing arc flash study which identified 96 incidents. Replace non-adjustable breakers with adjustable type or replace with newer panels that will accept adjustable breakers. f. Evaluate the 750 KW generator in building 175 to replace leaking oil seal on front main bearing or replace the unit. g. For all work indicated in paragraphs a thru f above, provide phasing plans to minimize power outages and interruptions to the campus, buildings, rooms, equipment and/or services. Indicate which work must be completed on nights or weekends. Indicate which work will require temporary power sources to be provided by the contractor. 2. Part - 2: Utilizing current electrical codes and VA requirements, conduct a review of the main electrical loop and identify violations and provide recommendations for improvements to the system. VA requirements can be found at VA OCFM http://www.cfm.va.gov/til/. The violations and recommendations will be used by VA to develop a future design project for construction. a. The review will include all underground vaults, conduits, duct banks, conductors, transformers and loop switches. b. The review will evaluate the general conditions, quantities, loads, locations, dimensions, serviceability and adherence to code and code violations. c. The review will provide recommendations for the changes in the location and path of the primary loop due to the decreased number of buildings now being served by the loop. Do not include buildings 7,10,11,12,18,24,25,42,60,118 and 122. 3. Part - 3: Conduct a review of the existing emergency power distribution system. Review findings will be used by VA to develop a future design project for construction. a. Identify the available emergency power capacity and condition of existing emergency power distribution equipment. b. Identify equipment not currently backed-up by emergency power that is required to be by the latest VA guidelines. VA requirements can be found at VA OCFM http://www.cfm.va.gov/til/. c. Review three (3) existing out-of-use emergency generators. The generators have been out of service for 20+ years. Evaluate if one or all can be reconditioned and relocated to new locations on campus for reuse to provide emergency power to buildings 51, 52, 53, and 79. 2.1 DESIGN TIMEFRAME Part - 1 Calendar Days Parts - 2 & 3 Schematic Submission (SC) 45 1st Submission VA Review of 35% (SC) 14 VA Review of 1st Submission Design Development Submission (DD) 45 2nd Submission VA Review of 65% (DD) 14 VA Review of 2nd Submission Construction Document Submission (CD) 35 3rd Submission VA Review of 95% (CD) 7 VA Review of 3rd Submission Construction Document Bid Set Submission (CDBS) 14 4th Submission VA Review of 100% CDBS 7 VA Review of 4th Submission Deliver Final Construction Document Bid Set 7 Final Submission 146 A/E Design 42 VA Review 188 Estimated Total Timeframe SUBMISSION OF FINAL BID DOCUMENTS: The original specifications (hard copy and electronic copy in Microsoft Word) and original drawings (hard copy 30" x 42" (76 cm. X 107 cm.) and electronic copy) shall be submitted to Engineering Service upon completion of the design. CONSTRUCTION PERIOD SERVICES: The A/E shall be responsible during the construction period for seven (7) site visits. The A/E shall also be responsible for reviewing and approving all material submittals. SUBMISSION OF AS-BUILT DRAWINGS: Upon completion of construction services the A/E shall be given one (1) copy of the contractor's working drawing from which the A/E will produce a working set of as-built drawings. All changes or revisions shown shall be incorporated into the as-built drawings and a disk shall be submitted to the Chief, Engineering Service with all as-built drawings in AutoCAD (AutoCAD drawings shall be compatible with 2016 or earlier version). As-built Drawings shall be due by no later than 30 calendar days after the substantial completion of construction work. Anticipated time for completion of design is approximately 188 calendar days including time for VA reviews. NOTE: A/E shall be responsible for conducting site visits for the purpose of data gathering, investigation and documentation of all existing conditions. Perform such investigations as required to accurately verify all existing conditions. Do not rely solely upon "as built" drawings. VA personnel will provide assistance with investigating the project site where prior experience with equipment and utilities will produce an appreciable advantage. The A/E firm shall be responsible for site review of the existing facility in order to field verify the owner's existing documents and as-build drawings. Any modifications that are required to be made as a result of the site review shall be communicated to VA and corrected by the A/E firm. In accordance with FAR 36.204, the estimated magnitude of the resulting construction price range is estimated between $2,000,000 and $5,000,000. Prospective firms are reminded that in accordance with VA Acquisition Regulations (VAAR) 852.219.10, at least 50 percent of the cost of personnel for contract performance of the contract shall be spent for employees of the SDVOSB concern or employees of other eligible service-disabled veteran-owned small business concerns. See VAAR Clause 819.7003 for eligibility requirements regarding Service Disabled Veteran Owned Small Business or Veteran Owned Small Business Set-Asides. Federal Acquisition Registrations require that federal contractors register in the Central Contractor Registration (CCR) database at www.sam.gov and enter all mandatory information into the system. Award cannot be made until the contractor has registered. Offerors are encouraged to ensure that they are registered in SAM prior to submitting their qualifications package. SUBMISSION REQUIREMENTS: Qualified A-E firms are required to respond if interested by submitting one (1) original completed Standard Form 330 qualification package Parts I and II to include all consultants (form available on-line at: http://www.gsa.gov/portal/forms/download/116486) In Section H of Part 1 include information regarding the firms estimating effectiveness (estimated costs vs. actual costs), an organizational chart of the firm, a design quality management plan, and past compliance with performance schedules (original design schedule vs. actual design completion time) for each key design project listed in Section F. All submissions must be bound in some manner (spiral, wire, binder, etc) and include a CD copy of the Standard Form 330 submittal. Prospective firms are required to address all selection criteria within submitted SF330 packages using additional pages as required. Selection criteria shall be in accordance with Federal Acquisition Regulation (FAR) Part 36.602-1 and VA Acquisition Regulation (VAAR) Part 836.602-1 as follows: 1. Professional qualifications necessary for satisfactory performance of required services: The qualifications of all individuals which will be used for these services, including the Project Manager, key personnel and any consultants, will be examined. 2. Specialized Experience: Including technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. 3. Professional Capacity: Ability for the firm in the designated geographic area of the project to accomplish the work in the required time. 4. Past Performance on contracts with the Federal Government, Department of Veterans Affairs and private industry in terms of cost control, quality of work and compliance with performance schedules. Limit past project references to those within the same scope as this advertisement. 5. Geographic Location and Facilities of Working Offices. Location in the general geographic area of the project and knowledge of the locality of the project. The proximity of each firm which would provide the professional services and familiarity with the area in which the project is located will be evaluated. This criterion will apply to the offices of both the Prime Firm and any Consultants. (In accordance with VAAR 805.207, the geographical area is limited to a 200 driving mile radius of Indianapolis, IN). 6. Reputation and standing of the firm and its principal officials with respect to professional performance, general management, and cooperativeness. 7. Record of significant claims against the firm because of improper or incomplete architectural and engineering services. 8. Specific experience and qualifications of personnel proposed for assignment to the project and their record of working together as a team. FAILURE TO CLEARLY ADDRESS ALL EIGHT LISTED EVALUATION CRITERIA AND INFORMATION REQUIRED BY THE SUBMISSION REQUIREMENTS BELOW MAY RESULT IN REJECTION OF SF330. Completed SF330s shall be sent to: NCO 11 Contracting Office, Attn: Felecia Beamen, 8888 Keystone Crossing, Suite 1100, Indianapolis, IN 46240, no later than 4:00 p.m. EST, June 9, 2016. Outer envelope or packaging shall clearly identify Solicitation number VA251-16-R-0256. Any request for assistance with submission or other procedural matters shall be submitted via email only (contact@example.gov). No faxed or emailed forms will be accepted. After the evaluation of submissions in accordance with the evaluation criteria listed herein, a 'short list' of three or more of the most highly qualified firms will be chosen for interviews to present their approach to the design to arrive at selection of the firm to enter into negotiations. Award of a Firm Fixed Price contract is anticipated by early October 2016. This is not a request for proposal. The Government will not pay for nor reimburse any costs associated with responding to this advertisement. The Government is under no obligation to award a contract as a result of this advertisement.

More opportunities from Department Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)

Same awarding agency

NAICS: 541380
New
Federal
Effluent Wastewater Testing - Saginaw VAMC
Solicitation # 36C25027Q0032
The Department of Veterans Affairs Network Contracting Office 10 is soliciting a firm fixed price contract for wastewater effluent laboratory analysis services at the Aleda E. Lutz VA Medical Center in Saginaw, Michigan. This procurement is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 541380. The scope of work requires the contractor to provide all labor, equipment, and supervision for the preparation, collection, storage, and transportation of wastewater effluent samples, as well as the performance of analytical testing and the provision of consultative services. All analysis must comply with 40 CFR Part 136, with specific requirements for PCB testing per the City of Saginaw Total PCB Minimization Program and mercury testing per Method 245.1. Formal analytical reports must be delivered to the facility GEMS Coordinator within seven business days of sampling. To be eligible for award, offerors must demonstrate at least three years of experience in wastewater effluent laboratory testing and one year of experience in sample collection, storage, and transportation. Additionally, a signed certification regarding limitations on subcontracting is mandatory for evaluation. The contractor is required to maintain a Quality Assurance Program and adhere to OSHA safety standards, as well as the City of Saginaw Code of Ordinances and Northwest Utilities Authority regulations. Performance is scheduled to begin on December 1, 2026, with invoicing submitted semi-annually or upon completion of service. The government will monitor performance based on turnaround times, customer service responsiveness, and the accuracy of quality control results.
Testing Laboratories and Services

POSTED

about 17 hours ago

DEADLINE

in 8 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS